TOTALLY IMPLANTABLE TOTAL ARTIFICIAL-HEART AND VENTRICULAR ASSIST DEVICE WITH MULTIPURPOSE MINIATURE ELECTROMECHANICAL ENERGY SYSTEM

被引:13
|
作者
TAKATANI, S
ORIME, Y
TASAI, K
OHARA, Y
NAITO, K
MIZUGUCHI, K
MAKINOUCHI, K
DAMM, G
GLUECK, J
LING, J
NOON, G
NOSE, Y
机构
[1] Department of Surgery, Baylor College of Medicine, Houston, Texas
关键词
TOTALLY IMPLANTABLE TOTAL ARTIFICIAL HEART; TOTALLY IMPLANTABLE VENTRICULAR ASSIST DEVICE; MINIATURE ELECTROMECHANICAL ENERGY SYSTEM; HYBRID CONTROLLER; EMERGENCY DRIVE PORT;
D O I
10.1111/j.1525-1594.1994.tb03301.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A multipurpose miniature electromechanical energy system has been developed to yield a compact, efficient, durable, and biocompatible total artificial heart (TAH) and ventricular assist device (VAD). Associated controller-driver electronics were recently miniaturized and converted into hybrid circuits. The hybrid controller consists of a microprocessor and controller, motor driver, Hall sensor, and commutation circuit hybrids. The sizing study demonstrated that all these components can be incorporated in the pumping unit of the TAH and VAD, particularly in the centerpiece of the TAH and the motor housing of the VAD. Both TAH and VAD pumping units will start when their power line is connected to either the internal power pack or the external battery unit. As a redundant driving and diagnostic port, an emergency port was newly added and will be placed in subcutaneous location. In case of system failure, the skin will be cut down, and an external motor drive or a pneumatic driver will be connected to this port to run the TAH. This will minimize the circulatory arrest time. Overall efficiency of the TAH without the transcutaneous energy transmission system was 14-18% to deliver pump outputs of 4-9 L/min against the right and left afterload pressures of 25 and 100 mm Hg. The internal power requirement ranged from 6 to 13 W. The rechargeable batteries such as NiCd or NiMH with 1 AH capacity can run the TAH for 30-45 min. The external power requirement, when TETS efficiency of 75% was assumed, ranged from 8 to 18 W. The accelerated endurance test in the 42-degrees-C saline bath demonstrated stable performance over 4 months. Long-term endurance and chronic animal studies will continue toward a system with 5 years durability by the year 2000.
引用
收藏
页码:80 / 92
页数:13
相关论文
共 50 条
  • [31] TOTALLY IMPLANTABLE LEFT-VENTRICULAR ASSIST DEVICE FOR HUMAN APPLICATION
    OZAWA, K
    SNOW, J
    SUKALAC, R
    TAKATANI, S
    KITAGAWA, M
    VALDES, F
    HARSAKI, H
    HILLEGASS, D
    CASTLE, C
    JACOBS, G
    KIRALY, R
    NOSE, Y
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1980, 26 : 461 - 465
  • [32] STAGED CARDIAC TRANSPLANTATION (SCTX) - TOTAL ARTIFICIAL-HEART (TAH) OR VENTRICULAR ASSIST PUMP (VAP)
    PAE, WE
    PIERCE, WS
    CAMPBELL, DB
    WALDHAUSEN, JA
    CIRCULATION, 1987, 76 (04) : 258 - 258
  • [33] Development of a totally implantable pulsatile centrifugal pump as a ventricular assist device
    Chou, NK
    Wang, SS
    Lin, YH
    Shyu, TJ
    Hsieh, KH
    Jan, GJ
    Chu, SH
    ARTIFICIAL ORGANS, 2001, 25 (08) : 603 - 606
  • [34] STAGED CARDIAC TRANSPLANTATION (SCTX) - TOTAL ARTIFICIAL-HEART (TAH) OR VENTRICULAR ASSIST PUMP (VAP)
    PAE, WE
    PIERCE, WS
    PENNOCK, JL
    CAMPBELL, DB
    ROSENBERG, G
    ARTIFICIAL ORGANS, 1987, 11 (04) : 329 - 329
  • [35] PROGRESS IN THE DEVELOPMENT OF A COMPLETELY IMPLANTABLE TOTAL ARTIFICIAL-HEART (TAH)
    JACOBS, G
    YOZU, R
    STACY, G
    SMITH, W
    WATANABE, T
    SHIMOMITSU, T
    NOSE, Y
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (10) : 892 - 892
  • [36] Left Ventricular Assist Device Failure With Total Artificial Heart Bridge to Heart Transplant
    Tushak, Zackary
    Wood, Taylor
    Quader, Mohammed
    Shah, Keyur B.
    CIRCULATION, 2020, 142
  • [37] SUCCESSFUL THERMAL MANAGEMENT OF A TOTALLY IMPLANTABLE VENTRICULAR ASSIST SYSTEM
    TASAI, K
    TAKATANI, S
    ORIME, Y
    DAMM, G
    OHARA, Y
    NAITO, K
    MAKINOUCHI, K
    MIZUGUCHI, K
    MATSUDA, Y
    SHIMONO, T
    GLUECK, J
    NOON, GP
    NOSE, Y
    ARTIFICIAL ORGANS, 1994, 18 (01) : 49 - 53
  • [38] TRANSCUTANEOUS OPTICAL TELEMETRY SYSTEM FOR AN IMPLANTABLE ELECTRICAL VENTRICULAR HEART ASSIST DEVICE
    MILLER, JA
    BELANGER, G
    SONG, I
    JOHNSON, F
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (03) : 370 - 372
  • [39] Compact Ventricular Assist Device and Total Artificial Heart Using Undulation Pump
    Imachi, Kou
    Saito, Itsuro
    Takiura, Koki
    Chinzei, Tsuneo
    Isoyama, Takashi
    Yambe, Tomoyuki
    Shiraishi, Yasuhiro
    Miura, Hidekazu
    Matsuki, Hidetoshi
    Mitamura, Yoshinori
    Inoue, Yusuke
    Okamoto, Eiji
    Umezu, Mitsuo
    Nemoto, Isao
    Abe, Yusuke
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3146 - +
  • [40] PLATELET AND FIBRINOGEN SURVIVAL IN CALVES IMPLANTED WITH ARTIFICIAL-HEART AND VENTRICULAR ASSIST DEVICE - CORRELATION WITH AUTOPSY FINDINGS
    ALMONDHIRY, H
    PAE, WE
    MILLER, CA
    PIERCE, WS
    THROMBOSIS AND HAEMOSTASIS, 1992, 67 (04) : 413 - 416