TOTALLY IMPLANTABLE TOTAL ARTIFICIAL-HEART AND VENTRICULAR ASSIST DEVICE WITH MULTIPURPOSE MINIATURE ELECTROMECHANICAL ENERGY SYSTEM

被引:13
|
作者
TAKATANI, S
ORIME, Y
TASAI, K
OHARA, Y
NAITO, K
MIZUGUCHI, K
MAKINOUCHI, K
DAMM, G
GLUECK, J
LING, J
NOON, G
NOSE, Y
机构
[1] Department of Surgery, Baylor College of Medicine, Houston, Texas
关键词
TOTALLY IMPLANTABLE TOTAL ARTIFICIAL HEART; TOTALLY IMPLANTABLE VENTRICULAR ASSIST DEVICE; MINIATURE ELECTROMECHANICAL ENERGY SYSTEM; HYBRID CONTROLLER; EMERGENCY DRIVE PORT;
D O I
10.1111/j.1525-1594.1994.tb03301.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A multipurpose miniature electromechanical energy system has been developed to yield a compact, efficient, durable, and biocompatible total artificial heart (TAH) and ventricular assist device (VAD). Associated controller-driver electronics were recently miniaturized and converted into hybrid circuits. The hybrid controller consists of a microprocessor and controller, motor driver, Hall sensor, and commutation circuit hybrids. The sizing study demonstrated that all these components can be incorporated in the pumping unit of the TAH and VAD, particularly in the centerpiece of the TAH and the motor housing of the VAD. Both TAH and VAD pumping units will start when their power line is connected to either the internal power pack or the external battery unit. As a redundant driving and diagnostic port, an emergency port was newly added and will be placed in subcutaneous location. In case of system failure, the skin will be cut down, and an external motor drive or a pneumatic driver will be connected to this port to run the TAH. This will minimize the circulatory arrest time. Overall efficiency of the TAH without the transcutaneous energy transmission system was 14-18% to deliver pump outputs of 4-9 L/min against the right and left afterload pressures of 25 and 100 mm Hg. The internal power requirement ranged from 6 to 13 W. The rechargeable batteries such as NiCd or NiMH with 1 AH capacity can run the TAH for 30-45 min. The external power requirement, when TETS efficiency of 75% was assumed, ranged from 8 to 18 W. The accelerated endurance test in the 42-degrees-C saline bath demonstrated stable performance over 4 months. Long-term endurance and chronic animal studies will continue toward a system with 5 years durability by the year 2000.
引用
收藏
页码:80 / 92
页数:13
相关论文
共 50 条
  • [1] DEVELOPMENT OF TOTALLY IMPLANTABLE ELECTROMECHANICAL ARTIFICIAL-HEART SYSTEMS - BAYLOR VENTRICULAR ASSIST SYSTEM
    SASAKI, T
    TAKATANI, S
    SHIONO, M
    SAKUMA, I
    GLUECK, J
    NOON, GP
    NOSE, Y
    DEBAKEY, ME
    ARTIFICIAL ORGANS, 1992, 16 (04) : 407 - 413
  • [2] DEVELOPMENT OF A TOTALLY IMPLANTABLE ELECTROMECHANICAL TOTAL ARTIFICIAL-HEART - BAYLOR TAH
    TAKATANI, S
    SHIONO, M
    SASAKI, T
    GLUECK, J
    NOON, GP
    NOSE, Y
    DEBAKEY, ME
    ARTIFICIAL ORGANS, 1992, 16 (04) : 398 - 406
  • [3] ARTIFICIAL-HEART - VENTRICULAR ASSIST DEVICE
    SEZAI, Y
    HASEGAWA, T
    MIYAMOTO, A
    KITAMURA, S
    UMEDA, S
    KAWANO, K
    SHINDOU, S
    RIKUKAWA, H
    SHIONO, M
    OGASAWARA, K
    ORIME, Y
    ATSUMI, K
    FUJIMASA, I
    IMACHI, K
    ARTIFICIAL ORGANS, 1988, 12 (05) : 461 - 461
  • [4] Ultracompact, completely implantable permanent use electromechanical ventricular assist device and total artificial heart
    Honda, N
    Inamoto, T
    Nogawa, M
    Takatani, S
    ARTIFICIAL ORGANS, 1999, 23 (03) : 253 - 261
  • [5] USE OF THE TOTAL ARTIFICIAL-HEART AND VENTRICULAR ASSIST DEVICE AS A BRIDGE TO TRANSPLANTATION
    PIFARRE, R
    SULLIVAN, H
    MONTOYA, A
    BAKHOS, M
    GRIECO, J
    FOY, BK
    BLAKEMAN, B
    ALTERGOTT, R
    LONCHYNA, V
    CALANDRA, D
    HINKAMP, T
    GRADY, K
    COSTANZONORDIN, MR
    JOURNAL OF HEART TRANSPLANTATION, 1990, 9 (06): : 638 - 643
  • [6] A TOTALLY IMPLANTABLE ELECTROMECHANICAL LEFT-VENTRICULAR ASSIST SYSTEM
    MILLER, PJ
    CHEN, H
    GREEN, GF
    LAFORGE, DH
    BRUGLER, JS
    JASSAWALLA, JS
    OYER, PE
    PORTNER, PM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (08) : 564 - 564
  • [7] IS A TOTALLY IMPLANTABLE ARTIFICIAL-HEART REALISTIC
    NOSE, Y
    ARTIFICIAL ORGANS, 1992, 16 (01) : 19 - 42
  • [8] The total artificial heart and implantable biventricular assist device
    Min B.G.
    Sun K.
    Journal of Artificial Organs, 2002, 5 (3) : 147 - 148
  • [9] RIGHT-LEFT VENTRICULAR OUTPUT BALANCE IN THE TOTALLY IMPLANTABLE ARTIFICIAL-HEART
    OLSEN, DB
    WHITE, RK
    LONG, JW
    KHANWILKAR, PS
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (06): : 359 - 364
  • [10] Totally implantable intrathoracic ventricular assist device
    Mussivand, TV
    Masters, RG
    Hendry, PJ
    Keon, WJ
    ANNALS OF THORACIC SURGERY, 1996, 61 (01): : 444 - 447