Fluoroscopic Comparison of Cervical Spine Motion Using LMA CTrach, C-MAC Videolaryngoscope and Macintosh Laryngoscope

被引:3
|
作者
Sahin, Tulay [1 ]
Arslan, Zehra Ipek [1 ]
Akansel, Gur [2 ]
Balaban, Onur [3 ]
Berk, Derya [4 ]
Solak, Mine [1 ]
Toker, Kamil [5 ]
机构
[1] Kocaeli Univ, Sch Med, Dept Anaesthesiol & Crit Care, Kocaeli, Turkey
[2] Kocaeli Univ, Sch Med, Dept Radiol, Kocaeli, Turkey
[3] Dumlupinar Univ, Dept Anaesthesiol & Pain, Kutahya, Turkey
[4] Adatip Hosp, Dept Anaesthesiol & Crit Care, Sakarya, Turkey
[5] Istinye Univ, Dept Anaesthesiol & Crit Care, Istanbul, Turkey
关键词
Cervical spine motion; LMA C Trach; videolaryngoscopy; fluoroscopy;
D O I
10.5152/TJAR.2018.53367
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: Endotracheal intubation should be performed with care when cervical spine (C-spine) injury is suspected. The aim of this study was to evaluate the movement of the C-spine using fluoroscopy during intubation with Laryngeal Mask Airway (LMA) CTrach, C-MAC videolaryngoscope and Macintosh laryngoscope. Methods: This was a single-centre, prospective, observational, controlled trial. In total, 22 surgical patients aged 18-65 years planned to undergo operation under general anaesthesia, were enrolled. X-ray images of the C-spine were obtained using fluoroscopy with the patients' head in a neutral position. All patients underwent laryngoscopy using a Macintosh blade, LMA CTrach and C-MAC videolaryngoscope, and fluoroscopic images of the C-spine were obtained. All the patients were intubated at the last laryngoscopy simulation (using the C-MAC). The atlanto-occipital distance (AOD) and angles between C0C1, C0C2, C0C3, C0C4, C1C2 and C2C3 lines were measured and compared between each device. Results: The mean AOD was measured as 20.4 mm in a neutral position, which decreased to 13.1, 17.2 and 12.3 mm after the insertion of the Macintosh laryngoscope, LMA CTrach and C-MAC videolaryngoscope, respectively. The differences were significant (p < 0.001). Moreover, significant difference was noted in C0C2, C0C3 and C1C2 angles with the insertion of the three devices (p < 0.001). The LMA CTrach resulted in significantly lesser C-spine movements in C0C2, C0C3 and C0C4 angles compared to the Macintosh laryngoscope and C-MAC videolaryngoscope (p < 0.001). Conclusion: The LMA CTrach resulted in lesser C-spine movements compared to Macintosh laryngoscope and C-MAC videolaryngoscope. In case of the C-spine injury, LMA CTrach may be preferred and may cause fewer traumas during endotracheal intubation.
引用
收藏
页码:44 / 50
页数:7
相关论文
共 50 条
  • [41] Clinical evaluation of C-MAC videolaryngoscope with or without use of stylet for endotracheal intubation in patients with cervical spine immobilization
    Nidhi Gupta
    Girija Prasad Rath
    Hemanshu Prabhakar
    Journal of Anesthesia, 2013, 27 : 663 - 670
  • [42] Comparison of the AP Advance™ Video Laryngoscope and C-MAC® Video Laryngoscope with the Macintosh 3 Blade for intubation of the difficult airway: a manikin study
    Davies, O.
    Kourteli, E.
    Cecconi, M.
    Garewel, D.
    Mir, F.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 116 (06) : E899 - E899
  • [43] Clinical evaluation of C-MAC videolaryngoscope with or without use of stylet for endotracheal intubation in patients with cervical spine immobilization
    Gupta, Nidhi
    Rath, Girija Prasad
    Prabhakar, Hemanshu
    JOURNAL OF ANESTHESIA, 2013, 27 (05) : 663 - 670
  • [44] A Randomized Comparison Simulating Face to Face Endotracheal Intubation of Pentax Airway Scope, C-MAC Video Laryngoscope, Glidescope Video Laryngoscope, and Macintosh Laryngoscope
    Choi, Hyun Young
    Oh, Young Min
    Kang, Gu Hyun
    Kang, Hyunggoo
    Jang, Yong Soo
    Kim, Wonhee
    Kim, Euichung
    Cho, Young Soon
    Choi, Hyukjoong
    Kim, Hyunjong
    Kim, Gyoung Yong
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [45] Intraocular pressure response to airway management: Comparison between LMA Supreme® and C-MAC® videolaryngoscope in day care surgery
    Kaur, Haramritpal
    Singh, Gurpreet
    Singh, Jaipreet
    Kaur
    Dhawan, Munish
    Singh, Amandeep
    ANAESTHESIA PAIN & INTENSIVE CARE, 2020, 24 (06) : 628 - 634
  • [46] Comparison of the C-MAC® and GlideScope® videolaryngoscopes in patients with cervical spine disorders and immobilisation
    Brueck, S.
    Trautner, H.
    Wolff, A.
    Hain, J.
    Mols, G.
    Pakos, P.
    Roewer, N.
    Lange, M.
    ANAESTHESIA, 2015, 70 (02) : 160 - 165
  • [47] Comparison of ease of intubation in right and left lateral position using C-MAC videolaryngoscope
    Bhat, Ravi
    Sanickop, C. S.
    Dhorigoll, M. G.
    Umrani, Vijay
    Suresh, S. N.
    ANAESTHESIA PAIN & INTENSIVE CARE, 2013, 17 (02) : 162 - 165
  • [48] Comparison of the conventional Macintosh laryngoscope, the Pentax Airwayscope, and the McGrath MAC video laryngoscope under restricted cervical motion: a manikin study
    Kotera, Atsushi
    Irie, Hiroki
    Iwashita, Shinsuke
    Taniguchi, Junichi
    Kasaoka, Shunji
    Kinoshita, Yoshihiro
    ACUTE MEDICINE & SURGERY, 2015, 2 (02): : 138 - 142
  • [49] A comparison of the McGrath® video-laryngoscope and the Macintosh laryngoscope in patients with cervical spine immobilisation
    Shippey, B.
    McGuire, B.
    Dalton, A.
    ANAESTHESIA, 2013, 68 (08) : 883 - 883
  • [50] A RANDOMISED COMPARATIVE STUDY OF TRUVIEW EVO2, C-MAC D-BLADE VIDEOLARYNGOSCOPE AND VIDEOENDOSCOPE WITH MACINTOSH LARYNGOSCOPE IN A DIFFICULT AIRWAY SCENARIO
    Pappu, A.
    Sharma, B.
    Jain, R.
    Dua, N.
    Sood, J.
    ANESTHESIA AND ANALGESIA, 2016, 123 : 698 - 699