Fluoroscopic Comparison of Cervical Spine Motion Using LMA CTrach, C-MAC Videolaryngoscope and Macintosh Laryngoscope

被引:3
|
作者
Sahin, Tulay [1 ]
Arslan, Zehra Ipek [1 ]
Akansel, Gur [2 ]
Balaban, Onur [3 ]
Berk, Derya [4 ]
Solak, Mine [1 ]
Toker, Kamil [5 ]
机构
[1] Kocaeli Univ, Sch Med, Dept Anaesthesiol & Crit Care, Kocaeli, Turkey
[2] Kocaeli Univ, Sch Med, Dept Radiol, Kocaeli, Turkey
[3] Dumlupinar Univ, Dept Anaesthesiol & Pain, Kutahya, Turkey
[4] Adatip Hosp, Dept Anaesthesiol & Crit Care, Sakarya, Turkey
[5] Istinye Univ, Dept Anaesthesiol & Crit Care, Istanbul, Turkey
关键词
Cervical spine motion; LMA C Trach; videolaryngoscopy; fluoroscopy;
D O I
10.5152/TJAR.2018.53367
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: Endotracheal intubation should be performed with care when cervical spine (C-spine) injury is suspected. The aim of this study was to evaluate the movement of the C-spine using fluoroscopy during intubation with Laryngeal Mask Airway (LMA) CTrach, C-MAC videolaryngoscope and Macintosh laryngoscope. Methods: This was a single-centre, prospective, observational, controlled trial. In total, 22 surgical patients aged 18-65 years planned to undergo operation under general anaesthesia, were enrolled. X-ray images of the C-spine were obtained using fluoroscopy with the patients' head in a neutral position. All patients underwent laryngoscopy using a Macintosh blade, LMA CTrach and C-MAC videolaryngoscope, and fluoroscopic images of the C-spine were obtained. All the patients were intubated at the last laryngoscopy simulation (using the C-MAC). The atlanto-occipital distance (AOD) and angles between C0C1, C0C2, C0C3, C0C4, C1C2 and C2C3 lines were measured and compared between each device. Results: The mean AOD was measured as 20.4 mm in a neutral position, which decreased to 13.1, 17.2 and 12.3 mm after the insertion of the Macintosh laryngoscope, LMA CTrach and C-MAC videolaryngoscope, respectively. The differences were significant (p < 0.001). Moreover, significant difference was noted in C0C2, C0C3 and C1C2 angles with the insertion of the three devices (p < 0.001). The LMA CTrach resulted in significantly lesser C-spine movements in C0C2, C0C3 and C0C4 angles compared to the Macintosh laryngoscope and C-MAC videolaryngoscope (p < 0.001). Conclusion: The LMA CTrach resulted in lesser C-spine movements compared to Macintosh laryngoscope and C-MAC videolaryngoscope. In case of the C-spine injury, LMA CTrach may be preferred and may cause fewer traumas during endotracheal intubation.
引用
收藏
页码:44 / 50
页数:7
相关论文
共 50 条
  • [21] Endotracheal intubation using the C-MAC® video laryngoscope or the Macintosh laryngoscope: A prospective, comparative study in the ICU
    Ruediger R Noppens
    Stephanie Geimer
    Nicole Eisel
    Matthias David
    Tim Piepho
    Critical Care, 16
  • [22] Comparison of the C-MAC®, Airtraq®, and Macintosh laryngoscopes in patients undergoing tracheal intubation with cervical spine immobilization
    McElwain, J.
    Laffey, J. G.
    BRITISH JOURNAL OF ANAESTHESIA, 2011, 107 (02) : 258 - 264
  • [23] Comparison of performance characteristics of C-MAC video, McCoy, and Macintosh laryngoscopes in elective cervical spine surgery
    Nair, Shalini M.
    Das Menon, Gokul
    George, Mathew
    Issac, Eldo
    Bhaskaran, Renjitha
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2021, 37 (04) : 569 - 573
  • [24] A randomised comparative study of "videoendoscope" with the Truview EVO2, C-MAC D blade videolaryngoscope and the Macintosh laryngoscope
    Pappu, Ameya
    Sharma, Bimla
    Jain, Rashmi
    Dua, Naresh
    Sood, Jayashree
    INDIAN JOURNAL OF ANAESTHESIA, 2020, 64 : 186 - 192
  • [25] Upper cervical spine movement during intubation: fluoroscopic comparison of the AirWay Scope, McCoy laryngoscope, and Macintosh laryngoscope
    Maruyama, K.
    Yamada, T.
    Kawakami, R.
    Kamata, T.
    Yokochi, M.
    Hara, K.
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 100 (01) : 120 - 124
  • [26] Comparative Performance of C-MAC Video Laryngoscope and Macintosh Direct Laryngoscope for Emergency Intubation
    Xue, Fu S.
    Liao, Xu
    Cheng, Yi
    ANNALS OF EMERGENCY MEDICINE, 2012, 60 (06) : 817 - 818
  • [27] Endotracheal intubation using the C-MAC® video laryngoscope or the Macintosh laryngoscope: A prospective, comparative study in the ICU
    Noppens, Ruediger R.
    Geimer, Stephanie
    Eisel, Nicole
    David, Matthias
    Piepho, Tim
    CRITICAL CARE, 2012, 16 (03):
  • [28] Intubation in the Intensive Care Unit: C-MAC video laryngoscope versus Macintosh laryngoscope
    Dey, S.
    Pradhan, D.
    Saikia, P.
    Bhattacharyya, P.
    Khandelwal, H.
    Adarsha, K. N.
    MEDICINA INTENSIVA, 2020, 44 (03) : 135 - 141
  • [29] Intubation with cervical spine immobilisation: a comparison between the KingVision videolaryngoscope and the Macintosh laryngoscope: A randomised controlled trial
    Aleksandrowicz, Dawid
    Wieczorek, Andrzej
    Gaszynski, Tomasz
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2018, 35 (05) : 399 - 401
  • [30] Comparison of the C-MAC® videolaryngoscope with the Macintosh, Glidescope® and Airtraq® laryngoscopes in easy and difficult laryngoscopy scenarios in manikins
    Maassen, R.
    van Zundert, A.