Correlation of Cord Blood pH, Base Excess, and Lactate Concentration Measured With a Portable Device for Identifying Fetal Acidosis

被引:9
|
作者
Labrecque, Lyne [1 ]
Provencal, Mathieu [1 ]
Caqueret, Aurore [1 ]
Wo, Bi Lan [2 ]
Bujold, Emmanuel [3 ]
Lariviere, Francois [1 ]
Bedard, Marie-Josee [2 ]
机构
[1] Ctr Hosp Univ Montreal, Dept Biochem, Montreal, PQ, Canada
[2] Ctr Hosp Univ Montreal, Dept Obstet & Gynecol, Montreal, PQ, Canada
[3] Univ Laval, Fac Med, Dept Obstet & Gynecol, Quebec City, PQ, Canada
关键词
Lactate; fetal scalp; portable device; point-of-care testing;
D O I
10.1016/S1701-2163(15)30539-9
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To determine the effectiveness of portable lactate analyzers in identifying fetal acidosis by correlating arterial and venous lactate values from umbilical cord blood with lactate, pH, and base excess measurements from central laboratory analyzers. Methods: We performed a prospective study using arterial and venous cord blood from 52 women with a singleton fetus delivered at term. We evaluated the correlation between the cord blood lactate concentration measured using two of the same portable devices (Lactate Plus, Nova Biomedical) with the result from a central laboratory analyzer. Analyses of the correlation between arterial lactate concentration measured on the portable device with arterial pH and base excess were then performed. Results: We observed a median arterial pH of 7.24 (range 7.05 to 7.35) and a median arterial lactate concentration of 3.7 mmol/L (range 1.7 to 8.8 mmol/L). An excellent correlation was observed between lactate concentrations measured by the two portable devices (arterial R-2 = 0.98 and venous R-2 = 0.98), and between the portable device and the central laboratory analyzer (arterial R-2 = 0.94 and venous R-2 = 0.95). In our population, the optimal cut-offs to predict a pH < 7.20 or a base excess > -8.0 mmol/L were a lactate concentration of 4.9 mmol/L and 5.3 mmol/L, respectively, according to receiver operator characteristic analysis. With a lactate concentration > 4.9 mmol/L, the portable device had a sensitivity of 82% and a specificity of 90% to identify samples with an arterial pH < 7.20. Conclusion: Cord blood lactate concentration measured with a portable device is a good predictor of cord blood base excess and pH. Future studies should be designed to correlate scalp blood lactate measurements with clinical outcomes.
引用
收藏
页码:598 / 604
页数:7
相关论文
共 30 条
  • [1] LACTATE IN FETAL TISSUE DURING HYPOXIA - CORRELATION TO LACTATE, PH AND BASE DEFICIT IN THE FETAL BLOOD
    KASTENDIECK, E
    PAULICK, R
    MARTIUS, J
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1988, 29 (01) : 61 - 71
  • [2] Correlation between blood lactate concentration and base excess during exercise
    Nagler, L. M.
    Kovacs, G.
    Tscherner, M.
    Kqiku, X.
    Olschewski, H.
    WIENER KLINISCHE WOCHENSCHRIFT, 2011, 123 (17-18) : A26 - A26
  • [3] To foetal monitoring by measuring lactate scalp: Correlation of lactate and pH measured in arterial and venous cord blood
    Labrecque, Lyne
    Caqueret, Aurore
    Provencal, Mathieu
    Bujold, Emmanuel
    Bedard, Marie-Josee
    CLINICAL BIOCHEMISTRY, 2012, 45 (13-14) : 1112 - 1112
  • [4] Base excess and lactate concentration in infusion solutions and blood products
    Zander, R
    ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 2002, 37 (06): : 359 - 363
  • [5] Predictive value of fetal scalp pH and base excess for fetal acidosis and poor neonatal outcome
    Tsikouras, Panagiotis
    Koukouli, Zacharoula
    Niesigk, Barbara
    Manav, Bachar
    Farmakides, George
    Csorba, Roland
    Galazios, Georgios
    Teichmann, Alexander Tobias
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2018, 31 (23): : 3166 - 3171
  • [6] Umbilical cord blood lactate:: A valuable tool in the assessment of fetal metabolic acidosis
    Gjerris, Anne Cathrine
    Staer-Jensen, Jette
    Jorgensen, Jan Stener
    Bergholt, Thomas
    Nickelsen, Carsten
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2008, 139 (01) : 16 - 20
  • [7] VASOPRESSIN CONCENTRATION IN CORD BLOOD - CORRELATION WITH METHOD OF DELIVERY AND CORD PH
    PARBOOSINGH, J
    LEDERIS, K
    SINGH, N
    OBSTETRICS AND GYNECOLOGY, 1982, 60 (02): : 179 - 183
  • [8] Fetal Reserve Index Significantly Outperforms Category System Predicting Cord Blood Base Excess and pH.
    Evans, Mark I.
    Eden, Robert D.
    Britt, David W.
    Evans, Shara M.
    Gallagher, Paula
    Schifrin, Barry S.
    REPRODUCTIVE SCIENCES, 2019, 26 : 319A - 319A
  • [9] Correlation of umbilical cord blood pH, base deficit, and lactate levels with outcomes of hypoxic newborns: A prospective study
    Qamar, Sumbul
    Ansari, Mohd Ayub
    Mohapatra, J. N.
    Khan, Sana Salim
    JOURNAL OF ACUTE DISEASE, 2023, 12 (03) : 114 - 120