AN IMPROVED CALIBRATION FOR TETHERED BALLOON WIND MEASUREMENTS

被引:2
|
作者
MORIARTY, WW
机构
[1] Moriarty Meteorological Services, Sunbury, Victoria
关键词
D O I
10.1007/BF00705382
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
A previously published technique for using tethered spherical balloons as anemometers for measuring light low-level winds has been further developed. Earlier data on the relationship between the aerodynamic drag coefficient and the Reynolds number of spherical rubber balloons were combined with a large number of new data and re-analysed; and the errors in the relationship were estimated. The results allowed a more accurate calculation of wind speed from the deflection of a tethered balloon from the vertical. When combined with a new technique for calculating the effects of the tether, this enabled fight to moderate low-level winds at fixed heights up to 600 m or more to be measured with simple, cheap, and readily mobile equipment; and a slight modification of the technique allowed measurement of winds in and above fog. Wind speeds measured by the balloon technique showed reasonably good agreement with measurements by an anemometer carried beneath the balloon.
引用
收藏
页码:183 / 196
页数:14
相关论文
共 50 条
  • [41] Dynamics Modeling and Motion Evaluation of a Near-Ground Tethered Balloon Cable System under Severe Wind Environments
    Lai, Zhenhua
    Tang, Mao
    Hu, Xiaojin
    Shu, Xin
    Huang, Weicheng
    Pan, Yongjun
    ACTUATORS, 2024, 13 (10)
  • [42] Improved calibration of vertical scanning optical profilometers for spherical profiles measurements
    Beguelin, Jeremy
    Scharf, Toralf
    Noell, Wilfried
    Voelkel, Reinhard
    OPTICAL FABRICATION, TESTING, AND METROLOGY VI, 2018, 10692
  • [43] Improved calibration method for displacement transformation coefficient in optical and visual measurements
    Haopeng Li
    Zurong Qiu
    Nanotechnology and Precision Engineering, 2023, 6 (01) : 16 - 29
  • [44] An improved calibration methodology and uncertainty assessment in measurements of microbubble size and concentration
    Stigter, R.
    Fiscaletti, D.
    Elsinga, G. E.
    van Terwisga, T.
    Westerweel, J.
    EXPERIMENTS IN FLUIDS, 2025, 66 (01)
  • [45] Improved calibration method for displacement transformation coefficient in optical and visual measurements
    Li, Haopeng
    Qiu, Zurong
    NANOTECHNOLOGY AND PRECISION ENGINEERING, 2023, 6 (01)
  • [46] MEASUREMENTS OF PLANAR MICROWAVE CIRCUITS USING AN IMPROVED TRL CALIBRATION METHOD
    Liu, Y.
    Tong, L.
    Tian, Y.
    Gao, B.
    PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2010, 109 : 263 - 278
  • [47] TETHERED WIND SYSTEMS FOR THE GENERATION OF ELECTRICITY
    RIEGLER, G
    RIEDLER, W
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1984, 106 (02): : 177 - 181
  • [48] A NEW ALGORITHM FOR EVALUATING CALIBRATION MEASUREMENTS ON WIND-TUNNEL FORCE BALANCES
    SCHNABL, F
    ZEITSCHRIFT FUR FLUGWISSENSCHAFTEN UND WELTRAUMFORSCHUNG, 1987, 11 (06): : 342 - 346
  • [49] Combined optical slope/height measurements of short wind waves:: principle and calibration
    Jähne, B
    Schmidt, M
    Rocholz, R
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (10) : 1937 - 1944
  • [50] A PRECISION KITE OR BALLOON-BORNE MINI-SONDE FOR WIND AND TURBULENCE MEASUREMENTS
    SMEDMAN, AS
    LUNDIN, K
    BERGSTROM, H
    HOGSTROM, U
    BOUNDARY-LAYER METEOROLOGY, 1991, 56 (03) : 295 - 307