Improved calibration method for displacement transformation coefficient in optical and visual measurements

被引:0
|
作者
Li, Haopeng [1 ]
Qiu, Zurong [1 ]
机构
[1] Tianjin Univ, Sch Precis Instruments & Optoelect Engn, State Key Lab Precis Measuring Technol & Instrumen, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
Displacement transformation coefficient (DTC); Laser and vision-based displacement measuring module (LVDMM); Displacement measurement; Locally weighted scatterplot smoothing (LOWESS); Calibration method;
D O I
10.1063/10.0016714
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Optical and visual measurement technology is used widely in fields that involve geometric measurements, and among such technology are laser and vision-based displacement measuring modules (LVDMMs). The displacement transformation coefficient (DTC) of an LVDMM changes with the coordinates in the camera image coordinate system during the displacement measuring process, and these changes affect the displacement measurement accuracy of LVDMMs in the full field of view (FFOV). To give LVDMMs higher accuracy in the FFOV and make them adaptable to widely varying measurement demands, a new calibration method is proposed to improve the displacement measurement accuracy of LVDMMs in the FFOV. First, an image coordinate system, a pixel measurement coordinate system, and a displacement measurement coordinate system are established on the laser receiving screen of the LVDMM. In addition, marker spots in the FFOV are selected, and the DTCs at the marker spots are obtained from calibration experiments. Also, a fitting method based on locally weighted scatterplot smoothing (LOWESS) is selected, and with this fitting method the distribution functions of the DTCs in the FFOV are obtained based on the DTCs at the marker spots. Finally, the calibrated distribution functions of the DTCs are applied to the LVDMM, and experiments conducted to verify the displacement measurement accuracies are reported. The results show that the FFOV measurement accuracies for horizontal and vertical displacements are better than +/- 15 mu m and +/- 19 mu m, respectively, and that for oblique displacement is better than +/- 24 mu m. Compared with the traditional calibration method, the displacement measurement error in the FFOV is now 90% smaller. This research on an improved calibration method has certain significance for improving the measurement accuracy of LVDMMs in the FFOV, and it provides a new method and idea for other vision-based fields in which camera parameters must be calibrated.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Improved calibration method for displacement transformation coefficient in optical and visual measurements
    Haopeng Li
    Zurong Qiu
    Nanotechnology and Precision Engineering, 2023, 6 (01) : 16 - 29
  • [2] An Improved Calibration Method to Determine the Strain Coefficient for Optical Fibre Sensing Cables
    An, Pengju
    Wei, Chaoqun
    Tang, Huiming
    Deng, Qinglu
    Yu, Bofan
    Fang, Kun
    PHOTONICS, 2021, 8 (10)
  • [3] IMPROVED EXPERIMENTAL METHOD FOR INTERNAL CONVERSION COEFFICIENT MEASUREMENTS
    BLICHERTTOFT, PH
    KUGLER, P
    ARKIV FOR FYSIK, 1964, 25 (04): : 317 - &
  • [4] IMPROVED EXPERIMENTAL METHOD FOR INTERNAL CONVERSION COEFFICIENT MEASUREMENTS
    BLICHERTTOFT, PH
    KUGLER, P
    ARKIV FOR FYSIK, 1964, 26 (03): : 241 - &
  • [5] Improved Calibration Procedure for Six-Port Based Precise Displacement Measurements
    Staszek, Kamil
    Linz, Sarah
    Lurz, Fabian
    Mann, Sebastian
    Weigel, Robert
    Koelpin, Alexander
    2016 IEEE TOPICAL CONFERENCE ON WIRELESS SENSORS AND SENSOR NETWORKS (WISNET), 2016, : 60 - 63
  • [6] A Novel Automatic Calibration Method for Displacement Sensors Based on the Spatial Transformation Theory
    Liang, Bing
    Liu, Wei
    Jiang, Xintong
    Feng, Di
    Liu, Kun
    Zhou, Mengde
    Li, Xiao
    Jia, Zhenyuan
    2019 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2019, : 1244 - 1249
  • [7] AN IMPROVED METHOD FOR MEASUREMENTS OF OPTICAL CONSTANTS BY REFLECTION
    AVERY, DG
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION B, 1952, 65 (390): : 425 - 428
  • [8] Improved calibration of vertical scanning optical profilometers for spherical profiles measurements
    Beguelin, Jeremy
    Scharf, Toralf
    Noell, Wilfried
    Voelkel, Reinhard
    OPTICAL FABRICATION, TESTING, AND METROLOGY VI, 2018, 10692
  • [9] The new approach to an optical noncontact method for small displacement measurements
    Michalski, A
    Sawicki, D
    IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2004, 7 (03) : 76 - 82
  • [10] Improved 3D displacement measurements method and calibration of a combined fringe projection and 2D-DIC system
    Siegmann, Philip
    Felipe-Sese, Luis
    Diaz-Garrido, Francisco
    OPTICS AND LASERS IN ENGINEERING, 2017, 88 : 255 - 264