Simultaneous 3-Dimensional Resolution Correction in SPECT Reconstruction with an Ordered-Subsets Expectation Maximization Algorithm

被引:0
|
作者
Takahashi, Yasuyuki [1 ]
Murase, Kenya [2 ]
Mochizuki, Teruhito [3 ]
Sugawara, Yoshifumi [3 ]
Maeda, Hisato [4 ]
Kinda, Akiyoshi [5 ]
机构
[1] Gunma Prefectural Coll Hlth Sci, Sch Radiol Technol, Dept Nucl Med Technol, 323-1 Kamioki Cho, Maebashi, Gunma 3710052, Japan
[2] Osaka Univ, Grad Sch Med, Course Hlth Sci, Dept Med Phys & Engn, Suita, Osaka, Japan
[3] Ehime Univ, Sch Med, Dept Radiol, Toon, Ehime, Japan
[4] Fujita Hlth Univ, Grad Sch Hlth Sci, Course Med Technol, Dept Med Phys & Engn, Toyoake, Aichi, Japan
[5] Toshiba Med Engn Lab, Ohtawara, Tochigi, Japan
关键词
3-dimensional distance-dependent resolution correction; ordered-subsets expectation maximization algorithm; transmission CT;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Collimators are used for the improvement of information about the positions of sources by limiting the incidence direction of gamma-rays and characteristic x-rays to detectors. In this study, we attempted to improve the spatial resolution of Tl-201 myocardial SPECT by using simultaneous 3-dimensional distance-dependent resolution correction (DRC) incorporated into the ordered-subsets expectation maximization algorithm. Methods: Simulation was performed with various sizes of balls, and measurement with a line-source phantom was performed at different source-detector distances. Imaging of a hot-rod phantom, the defect area of a myocardial phantom, and the myocardial thickness and cardiac lumen in a human study by (TlCl)-Tl-201 myocardial SPECT was evaluated before and after DRC. Results: We performed simulation by using 5 sizes of balls and found marked improvement in resolution in all x-, y-, and z-axis directions. In the line-source phantom, when the radial distance was very long (30.5 cm), the correction effects were slightly low. However, when the distance was similar to the clinically used rotation radius (22.5 cm), the correction effects were good in the hot-rod and myocardial phantoms and in the human study. Conclusion: DRC markedly improved the spatial resolution of SPECT images, suggesting that this method is useful for the quantification of infarcted areas by myocardial SPECT.
引用
收藏
页码:34 / 38
页数:5
相关论文
共 50 条
  • [31] Interest of the ordered subsets expectation maximization (OS-EM) algorithm in pinhole single-photon emission tomography reconstruction: a phantom study
    Christian Vanhove
    Michel Defrise
    Philippe R. Franken
    Hendrik Everaert
    Frank Deconinck
    Axel Bossuyt
    European Journal of Nuclear Medicine, 2000, 27 : 140 - 146
  • [32] Interest of the ordered subsets expectation maximization (OS-EM) algorithm in pinhole single-photon emission tomography reconstruction: a phantom study
    Vanhove, C
    Defrise, M
    Franken, PR
    Everaert, H
    Deconinck, F
    Bossuyt, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (02) : 140 - 146
  • [33] RESOLUTION CRITERIA FOR 3-DIMENSIONAL RECONSTRUCTION
    VANHEEL, M
    HARAUZ, G
    OPTIK, 1986, 73 (03): : 119 - 122
  • [34] Interest of the ordered subsets expectation maximization (OS-EM) algorithm in pinhole single-photon emission tomography reconstruction: A phantom study
    Vanhove, Christian
    Defrise, Michel
    Franken, Philippe R.
    Everaert, Hendrik
    Deconinck, Frank
    Bossuyt, Axel
    European Journal of Nuclear Medicine and Molecular Imaging, 2000, 27 (02) : 140 - 146
  • [35] IMPLEMENTATION OF 3-DIMENSIONAL RESOLUTION RECOVERY AND CTAC RECONSTRUCTION ALGORITHMS IN BRAIN SPECT IMAGING
    Wood, Marcia
    Farrell, Culann
    Hickson, Kevin
    Chappell, Bridget
    Rowe, Christopher
    INTERNAL MEDICINE JOURNAL, 2013, 43 : 28 - 28
  • [36] Application of the Ordered-Subsets Transmission Reconstruction Algorithm to Contrast-Enhanced Dual-Energy Digital Breast Tomosynthesis
    Lu, Yihuan
    Peng, Boyu
    Scaduto, David A.
    Zhao, Wei
    Gindi, Gene
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [37] Comparing ordered-subsets expectation maximization (OSEM) and filtered back-projection (FBP) as methods of reconstructions of [99mTcEDDA/HYNIC] octreotate SPECT in patients suffering from GEP-NET
    Lenda-Tracz, W.
    Glowa, B.
    Hubalewska-Dydejczyk, A.
    Sowa-Staszczak, A.
    Huszno, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S237 - S237
  • [38] Comparison of Different Types of Commercial Filtered Backprojection and Ordered-Subset Expectation Maximization SPECT Reconstruction Software
    Seret, Alain
    Forthomme, Julien
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2009, 37 (03) : 179 - 187
  • [39] Clinical impact of attenuation correction (AC) in the diagnosis of abdominal and pelvic tumors by FDG-PET with ordered subsets expectation maximization (OSEM) reconstruction.
    Higashi, T
    Saga, T
    Nakamoto, Y
    Ishimori, T
    Mamede, MH
    Ishizu, K
    Tadamura, E
    Matsumoto, K
    Fujita, T
    Mukai, T
    Konishi, J
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 298P - 298P
  • [40] ACCELERATED ORDERED-SUBSETS ALGORITHM BASED ON SEPARABLE QUADRATIC SURROGATES FOR REGULARIZED IMAGE RECONSTRUCTION IN X-RAY CT
    Kim, Donghwan
    Fessler, Jeffrey A.
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 1134 - 1137