Simultaneous 3-Dimensional Resolution Correction in SPECT Reconstruction with an Ordered-Subsets Expectation Maximization Algorithm

被引:0
|
作者
Takahashi, Yasuyuki [1 ]
Murase, Kenya [2 ]
Mochizuki, Teruhito [3 ]
Sugawara, Yoshifumi [3 ]
Maeda, Hisato [4 ]
Kinda, Akiyoshi [5 ]
机构
[1] Gunma Prefectural Coll Hlth Sci, Sch Radiol Technol, Dept Nucl Med Technol, 323-1 Kamioki Cho, Maebashi, Gunma 3710052, Japan
[2] Osaka Univ, Grad Sch Med, Course Hlth Sci, Dept Med Phys & Engn, Suita, Osaka, Japan
[3] Ehime Univ, Sch Med, Dept Radiol, Toon, Ehime, Japan
[4] Fujita Hlth Univ, Grad Sch Hlth Sci, Course Med Technol, Dept Med Phys & Engn, Toyoake, Aichi, Japan
[5] Toshiba Med Engn Lab, Ohtawara, Tochigi, Japan
关键词
3-dimensional distance-dependent resolution correction; ordered-subsets expectation maximization algorithm; transmission CT;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Collimators are used for the improvement of information about the positions of sources by limiting the incidence direction of gamma-rays and characteristic x-rays to detectors. In this study, we attempted to improve the spatial resolution of Tl-201 myocardial SPECT by using simultaneous 3-dimensional distance-dependent resolution correction (DRC) incorporated into the ordered-subsets expectation maximization algorithm. Methods: Simulation was performed with various sizes of balls, and measurement with a line-source phantom was performed at different source-detector distances. Imaging of a hot-rod phantom, the defect area of a myocardial phantom, and the myocardial thickness and cardiac lumen in a human study by (TlCl)-Tl-201 myocardial SPECT was evaluated before and after DRC. Results: We performed simulation by using 5 sizes of balls and found marked improvement in resolution in all x-, y-, and z-axis directions. In the line-source phantom, when the radial distance was very long (30.5 cm), the correction effects were slightly low. However, when the distance was similar to the clinically used rotation radius (22.5 cm), the correction effects were good in the hot-rod and myocardial phantoms and in the human study. Conclusion: DRC markedly improved the spatial resolution of SPECT images, suggesting that this method is useful for the quantification of infarcted areas by myocardial SPECT.
引用
收藏
页码:34 / 38
页数:5
相关论文
共 50 条
  • [21] Image Reconstruction Algorithm Using Weighted Mean of Ordered-Subsets EM and MART for Computed Tomography
    Abou Al-Ola, Omar M.
    Kasai, Ryosuke
    Yamaguchi, Yusaku
    Kojima, Takeshi
    Yoshinaga, Tetsuya
    MATHEMATICS, 2022, 10 (22)
  • [22] An ordered-subsets proximal preconditioned gradient algorithm for edge-preserving PET image reconstruction
    Mehranian, Abolfazl
    Rahmim, Arman
    Ay, Mohammad Reza
    Kotasidis, Fotis
    Zaidi, Habib
    MEDICAL PHYSICS, 2013, 40 (05)
  • [23] Comparison of several commercial ordered subsets - Expectation maximization reconstruction algorithms using simulation phantom
    Matsutomo, Norikazu
    Nagaki, Akio
    Onishi, Hideo
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [24] Effects of image reconstruction algorithm on neurotransmission PET studies in humans: Comparison between filtered backprojection and ordered subsets expectation maximization
    Takuya Morimoto
    Hiroshi Ito
    Akihiro Takano
    Yoko Ikoma
    Chie Seki
    Takashi Okauchi
    Katsuyuki Tanimoto
    Akira Ando
    Takahiro Shiraishi
    Taiga Yamaya
    Tetsuya Suhara
    Annals of Nuclear Medicine, 2006, 20 : 237 - 243
  • [25] Effects of image reconstruction algorithm on neurotransmission PET studies in humans: comparison between filtered backprojection and ordered subsets expectation maximization
    Morimoto, T
    Ito, H
    Takano, A
    Ikoma, Y
    Seki, C
    Okauchi, T
    Tanimoto, K
    Ando, A
    Shiraishi, T
    Yamaya, T
    Suhara, T
    ANNALS OF NUCLEAR MEDICINE, 2006, 20 (03) : 237 - 243
  • [26] 3-DIMENSIONAL BAYESIAN RECONSTRUCTION FOR SPECT
    BOWSHER, JE
    JOHNSON, VE
    QIAN, J
    XU, J
    FLOYD, CE
    JASZCZAK, RJ
    COLEMAN, RE
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P20 - P20
  • [27] An overview of fast convergent ordered-subsets reconstruction methods for emission tomography based on the incremental EM algorithm
    Hsiao, Ing-Tsung
    Khurd, Parmeshwar
    Rangarajan, Anand
    Gindi, Gene
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 429 - 433
  • [28] New method for tuning hyperparameter for the total variation norm in the maximum a posteriori ordered subsets expectation maximization reconstruction in SPECT myocardial perfusion imaging
    Yang, Zhaoxia
    Krol, Andrzej
    Xu, Yuesheng
    Feiglin, David H.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [29] Modified total variation norm for the maximum a posteriori ordered subsets expectation maximization reconstruction in fan-beam SPECT brain perfusion imaging
    Krol, Andrzej
    Yang, Zhaoxia
    Xu, Yuesheng
    Wismueller, Axel
    Feiglin, David H.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [30] Pediatric 99mTc-MDP Bone SPECT with Ordered Subset Expectation Maximization Iterative Reconstruction with Isotropic 3D Resolution Recovery
    Stansfield, Eryn Caamano
    Sheehy, Niall
    Zurakowski, David
    Vija, A. Hans
    Fahey, Frederic H.
    Treves, S. Ted
    RADIOLOGY, 2010, 257 (03) : 793 - 801