COMPARATIVE STUDY OF FOREARM FRACTURES TREATED WITH LOCKING COMPRESSION PLATE LIMITED CONTACT DYNAMIC COMPRESSION PLATE

被引:0
|
作者
Reddy, B. Jayachandra [1 ]
Abhishek, L. [1 ]
Kathyayini, R. [2 ]
机构
[1] Govt Med Coll, Dept Orthopaed, Ananthapuram, Andhra Pradesh, India
[2] Rajarajeshwari Med Coll, Dept Gen Med, Bangalore, Karnataka, India
关键词
LCP; LC-DCP; PC-FIX; biologic plating;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: This study has been carried out to compare the functional outcome of fracture fixation in diaphyseal forearm fractures by using Locking Compression Plate versus Limited contact dynamic compression Plate. To study the difference in the duration of union & complications with LCP & LC-DCP. METHODOLOGY: It is a prospective randomised comparative study which was carried out from December 2012 to December 2014 in our Institution. In Group I, 20 patients were subjected to open reduction and internal fixation with 3.5 mm stainless steel LCP and locking head/nonlocking screws. In Group II, 20 patients were managed by 3.5mm LCDCP and non-locking screws. Clinical assessments regarding pain and function, radiological assessments were undertaken at the final follow-up. RESULTS-The time required for LCP fixation (mean 93.5 min, range 75-120 min) was found to be more than that required for LC-DCP (mean 81.94 min, range 60-110 min). But this time difference was not significant (P=0.07, unpaired t test). The mean time of union for the forearm fixed with LCP was found to be 18 weeks (range 14-26 weeks) in comparison to 16 weeks (range 10-22 weeks) for the LC-DCP group. CONCLUSION-LC plating is an effective treatment option for fractures shaft of forearm. The present study could not prove the superiority of LCP over LC-DCP. It is the proper application of the principles of plating and not the type of plate which decides the outcome. Further long-term multicentric study is required to prove behaviors of the implant.
引用
收藏
页码:2001 / 2010
页数:10
相关论文
共 50 条
  • [41] A biomechanical comparison of 3.5 locking compression plate fixation to 3.5 limited contact dynamic compression plate fixation in a canine cadaveric distal humeral metaphyseal gap model
    Filipowicz, D.
    Lanz, O.
    McLaughlin, R.
    Elder, S.
    Werre, S.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2009, 22 (04) : 270 - 277
  • [42] Comparison of Fixation between Dynamic Compression Plate Vs Locking Compression Plate in Lower Limb Diaphyseal Fractures by Bridge Plating Technique
    Aziz, Shaheryar
    Ahmed, Faheem
    Aslam, Muhammad Usman
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2019, 13 (04): : 1011 - 1014
  • [43] Comparison of Locking Compression Plate and Dynamic Compression Plate with Cancellous Bone Graft in Treating Non-Union of Humeral Shaft Fractures
    Khalid, Muhammad Usman
    Saeed, Kazi Muhammad
    Javed, Muhammad Bilal
    Akhtar, Muhammad
    Gillani, Syed Faraz Ul Hassan Shah
    ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN, 2019, 25 (02):
  • [44] Unilateral locking plate versus unilateral locking plate combined with compression bolt for Schatzker I–IV tibial plateau fractures: a comparative study
    Zhongzheng Wang
    Zhanle Zheng
    Yuchuan Wang
    Yanbin Zhu
    Zhanchao Tan
    Wei Chen
    Zhiyong Hou
    Yingze Zhang
    International Orthopaedics, 2022, 46 : 1133 - 1143
  • [45] FRACTURES TREATED WITH BAGBY COMPRESSION BONE PLATE
    BAGBY, GW
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1975, 57 (07): : 1031 - 1031
  • [46] Diaphyseal Humeral Fractures Treated by Bracing versus Dynamic Compression Plate
    Kumar, Bheesham
    Kumar, Ashok
    Das Mheshwari, Lachhman
    Tunio, Zamir Hussain
    Jhatiyal, Rizwan Ali
    Umrani, Khawand Bux
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (06): : 1466 - 1468
  • [47] Bone plate fixation: An evaluation of interface contact area and force of the dynamic compression plate (DCP) and the limited contact dynamic compression plate (LC-DCP) applied to cadaveric bone
    Field, JR
    Hearn, TC
    Caldwell, CB
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (05) : 368 - 373
  • [48] Outcome of forearm shaft fractures in adults treated by open reduction and internal fixation with Dynamic Compression Plate (DCP)
    Nasab, Seyed Abdolhossein Mehdi
    Sarrafan, Nasser
    Arti, Hamidreza
    Aliabadi, Gholamhossein
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2012, 28 (01) : 45 - 48
  • [49] Comparative evaluation of dynamic compression plate and horn plate for the repair of long bone fractures in dogs
    Thakur, N.
    Singh, K.
    Mohindroo, J.
    Gopinathan, A.
    INDIAN JOURNAL OF ANIMAL SCIENCES, 2012, 82 (02): : 159 - 161
  • [50] Development of the Locking Compression Plate
    Frigg, R
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2003, 34 : 6 - 10