COMPARATIVE STUDY OF FOREARM FRACTURES TREATED WITH LOCKING COMPRESSION PLATE LIMITED CONTACT DYNAMIC COMPRESSION PLATE

被引:0
|
作者
Reddy, B. Jayachandra [1 ]
Abhishek, L. [1 ]
Kathyayini, R. [2 ]
机构
[1] Govt Med Coll, Dept Orthopaed, Ananthapuram, Andhra Pradesh, India
[2] Rajarajeshwari Med Coll, Dept Gen Med, Bangalore, Karnataka, India
关键词
LCP; LC-DCP; PC-FIX; biologic plating;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: This study has been carried out to compare the functional outcome of fracture fixation in diaphyseal forearm fractures by using Locking Compression Plate versus Limited contact dynamic compression Plate. To study the difference in the duration of union & complications with LCP & LC-DCP. METHODOLOGY: It is a prospective randomised comparative study which was carried out from December 2012 to December 2014 in our Institution. In Group I, 20 patients were subjected to open reduction and internal fixation with 3.5 mm stainless steel LCP and locking head/nonlocking screws. In Group II, 20 patients were managed by 3.5mm LCDCP and non-locking screws. Clinical assessments regarding pain and function, radiological assessments were undertaken at the final follow-up. RESULTS-The time required for LCP fixation (mean 93.5 min, range 75-120 min) was found to be more than that required for LC-DCP (mean 81.94 min, range 60-110 min). But this time difference was not significant (P=0.07, unpaired t test). The mean time of union for the forearm fixed with LCP was found to be 18 weeks (range 14-26 weeks) in comparison to 16 weeks (range 10-22 weeks) for the LC-DCP group. CONCLUSION-LC plating is an effective treatment option for fractures shaft of forearm. The present study could not prove the superiority of LCP over LC-DCP. It is the proper application of the principles of plating and not the type of plate which decides the outcome. Further long-term multicentric study is required to prove behaviors of the implant.
引用
收藏
页码:2001 / 2010
页数:10
相关论文
共 50 条
  • [21] Comparison of limited-contact dynamic compression plate and locking compression plate constructs for proximal interphalangeal joint arthrodesis in the horse
    Rocconi, Richard A.
    Carmalt, James L.
    Sampson, Sarah N.
    Elder, Steve H.
    Gilbert, Eric E.
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2015, 56 (06): : 615 - 619
  • [22] A MECHANICAL COMPARISON OF THE DYNAMIC COMPRESSION PLATE, LIMITED CONTACT DYNAMIC COMPRESSION PLATE, AND POINT-CONTACT FIXATOR
    MICLAU, T
    REMIGER, A
    TEPIC, S
    LINDSEY, R
    MCIFF, T
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1995, 9 (01) : 17 - 22
  • [23] Plate fixation of clavicle fractures: A comparative study between Reconstruction Plate and Dynamic Compression Plate
    Shahid, Rizwan
    Mushtaq, Abid
    Maqsood, Mohammad
    ACTA ORTHOPAEDICA BELGICA, 2007, 73 (02): : 170 - 174
  • [24] Mechanical comparison of 3.5 mm broad dynamic compression plate, broad limited-contact dynamic compression plate, and narrow locking compression plate systems using interfragmentary gap models
    Uhl, Justin M.
    Seguin, Bernard
    Kapatkin, Amy S.
    Schulz, Kurt S.
    Garcia, Tanya C.
    Stover, Susan M.
    VETERINARY SURGERY, 2008, 37 (07) : 663 - 673
  • [25] Management of Both Bones Forearm Fractures with Dynamic Compression Plate
    Mathew, Jerson John
    Madhukar
    Thomas, Jithin Jose
    Chidambaram, Raja Nadar
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (11): : 273 - 275
  • [26] Locking Compression Plate (LCP). An osteosynthesis plate based on the dynamic compression plate and the point contact fixator (PC-Fix)
    Frigg, R
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2001, 32 : SB63 - SB66
  • [27] Comparison of the effect on bone healing process of different implants used in minimally invasive plate osteosynthesis: limited contact dynamic compression plate versus locking compression plate
    Zichao Xue
    Haitao Xu
    Haoliang Ding
    Hui Qin
    Zhiquan An
    Scientific Reports, 6
  • [28] Comparison of the effect on bone healing process of different implants used in minimally invasive plate osteosynthesis: limited contact dynamic compression plate versus locking compression plate
    Xue, Zichao
    Xu, Haitao
    Ding, Haoliang
    Qin, Hui
    An, Zhiquan
    SCIENTIFIC REPORTS, 2016, 6
  • [29] In vitro biomechanical comparison of locking compression plate fixation and limited-contact dynamic compression plate fixation of osteotomized equine third metacarpal bones
    Sod, Gary A.
    Mitchell, Colin F.
    Hubert, Jeremy D.
    Martin, George S.
    Gill, Marjorie S.
    VETERINARY SURGERY, 2008, 37 (03) : 283 - 288
  • [30] Biomechanical Comparison of Locking Compression Plate and Limited Contact Dynamic Compression Plate Combined with an Intramedullary Rod in a Canine Femoral Fracture-Gap Model
    Matres-Lorenzo, Luis
    Diop, Amadou
    Maurel, Nathalie
    Boucton, Marie-Charlotte
    Bernard, Fabrice
    Bernarde, Antoine
    VETERINARY SURGERY, 2016, 45 (03) : 319 - 326