AN EVALUATION OF HEATING AND VENTILATION CONTROL STRATEGIES FOR LIVESTOCK BUILDINGS

被引:9
|
作者
ZHANG, Y [1 ]
BARBER, EM [1 ]
机构
[1] UNIV SASKATCHEWAN,DEPT AGR & BIORESOURCE ENGN,SASKATOON,SK S7N 0W0,CANADA
来源
关键词
D O I
10.1006/jaer.1995.1016
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Thermal responses and supplemental heat consumption of a livestock building airspace were investigated using a simulation program and Typical Meterological Year weather data for a cold (-23 to -32 degrees C) and a warm day (-4 to 7 degrees C) in the Canadian Prairie Region. Three different control strategies using different sizes of heating/ventilating equipment and different controller time constants were evaluated. In an either-or-temperature (EOT) control, stage 1 ventilation was provided continuously by fan 1; stage 2 ventilation and the heater were controlled by the same temperature actuated switch such that either the heater was on or stage 2 ventilation fan 2 was on, but not both. In an either-or-neither temperature (EONT) control, stage 1 ventilation was provided continuously and the heater and stage 2 ventilation were controlled by separate actuated switches with a fixed interstage differential. In a temperature-humidity control (THC), all stages of ventilation were controlled thermostatically and the heater was controlled by a humidistat. THC control strategy provided the best thermal response and used the least supplemental heat. EOT control could achieve a variable ventilation rate for moisture control when fans and heater were correctly designed. EONT control provided good temperature control but failed to control humidity. Oversizing of heating/ventilating equipment resulted in poorer thermal response and higher energy consumption for EOT and EONT systems but had little effect on the THC system. Controllers with large time constants economized the use of supplemental heat but introduced poor thermal responses for all three control strategies.
引用
收藏
页码:217 / 225
页数:9
相关论文
共 50 条
  • [31] HUMAN-BEHAVI ORORIENTED CONTROL STRATEGIES FOR NATURAL VENTILATION IN OFFICE BUILDINGS
    Wang, Haojie
    Chen, Qingyan
    BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 1731 - 1738
  • [32] Computational analysis of ceiling inlet ventilation systems for livestock buildings
    Khankari, KK
    Karki, KC
    Patankar, SV
    Janni, K
    LIVESTOCK ENVIRONMENT V, VOLS I AND II, 1997, : 32 - 39
  • [33] Experimental Verification of a Theory for Ventilation of Livestock Buildings by Natural Convection
    Down, M. J.
    Foster, M. P.
    McMahon, T. A.
    JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1990, 45 (04): : 269 - 279
  • [34] VENTILATION AND INSULATION GUIDES - STEPS TO MORE USEFUL LIVESTOCK BUILDINGS
    ANDERSON, ED
    FARM QUARTERLY, 1972, 27 (04): : 78 - &
  • [35] Energy efficiency optimization of combined ventilation systems in livestock buildings
    Ecim-Djuric, Olivera
    Topisirovic, Goran
    ENERGY AND BUILDINGS, 2010, 42 (08) : 1165 - 1171
  • [36] Evaluation of hypocaust heating of buildings
    Bansal, N.K.
    Shail
    Bhandari, M.S.
    International Journal of Ambient Energy, 1999, 20 (02): : 67 - 78
  • [37] Sustainable Buildings: Heating, Ventilation, and Air-Conditioning
    Calautit, John Kaiser
    Chaudhry, Hassam Nasarullah
    ENERGIES, 2022, 15 (21)
  • [38] Strategies for Natural Ventilation of Urban Office Buildings
    Potangaroa, Regan
    Aynsley, Richard
    INTERNATIONAL JOURNAL OF VENTILATION, 2009, 8 (02) : 117 - 122
  • [39] Sustainable ventilation strategies in buildings: CFD research
    Cuce, Erdem
    Sher, Farooq
    Sadiq, Hamad
    Cuce, Pinar Mert
    Guclu, Tamer
    Besir, Ahmet B.
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2019, 36
  • [40] A literature review of night ventilation strategies in buildings
    Solgi, Ebrahim
    Hamedani, Zahra
    Fernando, Ruwan
    Skates, Henry
    Orji, Nnamdi Ezekiel
    ENERGY AND BUILDINGS, 2018, 173 : 337 - 352