AN EVALUATION OF HEATING AND VENTILATION CONTROL STRATEGIES FOR LIVESTOCK BUILDINGS

被引:9
|
作者
ZHANG, Y [1 ]
BARBER, EM [1 ]
机构
[1] UNIV SASKATCHEWAN,DEPT AGR & BIORESOURCE ENGN,SASKATOON,SK S7N 0W0,CANADA
来源
关键词
D O I
10.1006/jaer.1995.1016
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Thermal responses and supplemental heat consumption of a livestock building airspace were investigated using a simulation program and Typical Meterological Year weather data for a cold (-23 to -32 degrees C) and a warm day (-4 to 7 degrees C) in the Canadian Prairie Region. Three different control strategies using different sizes of heating/ventilating equipment and different controller time constants were evaluated. In an either-or-temperature (EOT) control, stage 1 ventilation was provided continuously by fan 1; stage 2 ventilation and the heater were controlled by the same temperature actuated switch such that either the heater was on or stage 2 ventilation fan 2 was on, but not both. In an either-or-neither temperature (EONT) control, stage 1 ventilation was provided continuously and the heater and stage 2 ventilation were controlled by separate actuated switches with a fixed interstage differential. In a temperature-humidity control (THC), all stages of ventilation were controlled thermostatically and the heater was controlled by a humidistat. THC control strategy provided the best thermal response and used the least supplemental heat. EOT control could achieve a variable ventilation rate for moisture control when fans and heater were correctly designed. EONT control provided good temperature control but failed to control humidity. Oversizing of heating/ventilating equipment resulted in poorer thermal response and higher energy consumption for EOT and EONT systems but had little effect on the THC system. Controllers with large time constants economized the use of supplemental heat but introduced poor thermal responses for all three control strategies.
引用
收藏
页码:217 / 225
页数:9
相关论文
共 50 条
  • [21] A new approach to controlled natural ventilation of livestock buildings
    Andonov, K
    Daskalov, P
    Martev, K
    BIOSYSTEMS ENGINEERING, 2003, 84 (01) : 91 - 100
  • [22] Demand Control Strategies of a PCM Enhanced Ventilation System for Residential Buildings
    Hu, Yue
    Heiselberg, Per Kvols
    Larsen, Tine Steen
    APPLIED SCIENCES-BASEL, 2020, 10 (12):
  • [23] SOLAR-ENERGY FOR SUPPLEMENTAL HEATING OF LIVESTOCK BUILDINGS
    YEXLEY, DP
    HELLICKSON, MA
    WITMER, WB
    AGRICULTURAL ENGINEERING, 1977, 58 (10): : 50 - 51
  • [24] Ventilation and Air Heating of Residential Buildings.
    Bierling, H.-J.
    Eta. Elektrowarme im technischen Ausbau, 1985, 43 (01):
  • [25] THE VENTILATION AND HEATING EQUIPMENT IN OFFICE AND INDUSTRIAL BUILDINGS
    不详
    KALTE UND KLIMATECHNIK, 1982, 35 (05): : 188 - 188
  • [26] HEATING, VENTILATION AND AIR CONDITIONING OF BUILDINGS MONUMENT
    Muntea, Cornel
    Domnita, Florin
    NANO, BIO AND GREEN - TECHNOLOGIES FOR A SUSTAINABLE FUTURE CONFERENCE PROCEEDINGS, SGEM 2016, VOL II, 2016, : 593 - 600
  • [27] Low carbon operation optimisation strategies for heating, ventilation and air conditioning systems in office buildings
    Shen, Meng
    Tang, Baojun
    Zhang, Keai
    INTERNATIONAL JOURNAL OF PRODUCTION RESEARCH, 2024, 62 (18) : 6781 - 6800
  • [28] Airflow pattern control in livestock buildings
    Zhang, GQ
    SECOND I.F.A.C./I.S.H.S. WORKSHOP ON MATHEMATICAL AND CONTROL APPLICATIONS IN AGRICULTURE AND HORTICULTURE, 1996, (406): : 373 - 382
  • [29] Climatic Cooling Potential Evaluation and Ventilation Strategies Optimization for City Buildings in China
    Zhang, Yin
    Cheng, Rui
    Long, Enshen
    Wang, Xin
    PROCEEDINGS OF 2019 16TH INTERNATIONAL BHURBAN CONFERENCE ON APPLIED SCIENCES AND TECHNOLOGY (IBCAST), 2019, : 692 - 696
  • [30] Integrated predictive adaptive control of heating, cooling ventilation, daylighting and electrical lighting in buildings
    Baker, L.G.
    Brouwer, A.H.M.
    Rabuska, R.
    2001, Gordon and Breach Science Publishers (21) : 2 - 3