X-RAY-IMAGING USING AMORPHOUS SELENIUM - INHERENT SPATIAL-RESOLUTION

被引:174
|
作者
QUE, W
ROWLANDS, JA
机构
[1] Reichmann Research Building, Sunnybrook Health Science Centre, University of Toronto, Toronto, Ontario, M4N 3M5
关键词
AMORPHOUS SELENIUM; SPATIAL RESOLUTION; DIAGNOSTIC X-RAY IMAGING;
D O I
10.1118/1.597471
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This is a theoretical study of the inherent spatial resolution of the latent image on the surface of an amorphous selenium (a-Se) plate used for diagnostic x-ray imaging. The following effects are considered: (A) ranges of primary photoelectrons; (B) reabsorption of K fluorescence; (C) reabsorption of Compton scattered photons; (D) diffusion; (E) the geometric effect due to oblique incidence of x rays; (F) electrostatic effect; and (G) the space charge effect. The modulation transfer function of a-Se in the diagnostic x-ray energy range has been estimated. In conclusion, (A) and (E) are the main factors limiting the resolution, and for diagnostic x rays, the inherent spatial resolution of 2-Se plates is much better than that of Csl layers used in x-ray image intensifiers. © 1995, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:365 / 374
页数:10
相关论文
共 50 条
  • [11] X-RAY-IMAGING USING AMORPHOUS SELENIUM - FEASIBILITY OF A FLAT-PANEL SELF-SCANNED DETECTOR FOR DIGITAL RADIOLOGY
    ZHAO, W
    ROWLANDS, JA
    MEDICAL PHYSICS, 1995, 22 (10) : 1595 - 1604
  • [12] OPTIMIZATION OF THE SPATIAL-RESOLUTION OF MOVING OBJECT IMAGING WITH MEDICAL X-RAY SYSTEMS
    THOEN, PJ
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1982, 375 : 107 - 111
  • [13] TIME RESOLVED SOFT-X-RAY IMAGING WITH SUBMICRON SPATIAL-RESOLUTION (INVITED)
    WILLI, O
    AFSHARRAD, T
    DESSELBERGER, M
    DUNNE, M
    EDWARDS, J
    KHATTAK, F
    TAYLOR, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (10): : 4818 - 4822
  • [14] X-RAY-IMAGING USING SYNCHROTRON RADIATION
    DUKE, PJ
    CHEMISTRY IN BRITAIN, 1986, 22 (09) : 843 - &
  • [15] SPATIAL-RESOLUTION CHARACTERISTICS OF AN AXISYMMET X-RAY MICROSCOPE
    AHLSTROM, HG
    BOYLE, MJ
    PRICE, RH
    ZEHNPFENNIG, T
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (09): : 1195 - 1196
  • [16] THE INCREASE OF SPATIAL-RESOLUTION OF THE X-RAY COMPUTING TOMOGRAPHY
    VAINBERG, EI
    FAINGOIZ, ML
    DOKLADY AKADEMII NAUK SSSR, 1986, 286 (04): : 875 - 878
  • [17] DIGITAL X-RAY-IMAGING
    MYERS, MJ
    BRITISH JOURNAL OF RADIOLOGY, 1980, 53 (630): : 614 - 614
  • [18] DIGITAL X-RAY-IMAGING
    COWEN, AR
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1991, 2 (08) : 691 - 707
  • [19] AN ALTERNATIVE TO X-RAY-IMAGING
    LYTLE, D
    PHOTONICS SPECTRA, 1992, 26 (12) : 148 - 148
  • [20] BACKSCATTER X-RAY-IMAGING
    BOSSI, RH
    FRIDDELL, KD
    NELSON, JM
    MATERIALS EVALUATION, 1988, 46 (11) : 1462 - 1467