NEW DEVELOPMENT OF HGI2 X-RAY AND SOFT GAMMA-RAY DETECTOR FOR SYNCHROTRON RADIATION RESEARCH AND DOSIMETRY APPLICATIONS

被引:3
|
作者
GERVINO, G [1 ]
MONTICONE, E [1 ]
机构
[1] IST ELETTROTECNICO NAZL GALILEO FERRARIS,I-10127 TURIN,ITALY
关键词
D O I
10.1016/0924-4247(92)80028-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes recent progress in the development of HgI2 as an X-ray and soft gamma-ray detector for synchrotron radiation research and dosimetry application. The high efficiency of the detector depends on the photon absorption inside the crystal and on the free charge carrier collection at the electrodes under the influence of the applied bias. The dominant mechanisms determining the collection of charge carriers, produced by incident ionizing radiations, are the trapping-detrapping phenomena and the carrier drift mobility. The relative role of these two mechanisms, photon absorption and carrier collection, is related to the thickness of the HgI2 crystal. The analysis of trapping-detrapping phenomena, which are strongly related to the detector fabrication process, are discussed and the measurement of the carrier drift mobility, cutting the crystal parallel and perpendicular to the c-axis, is presented. The results of energy resolution measurements obtained exposing HgI2 detector prototypes of different thickness and with the electrodes realized by evaporizing different metals on the crystal surface, to X- and gamma-radiactive source, are presented and discussed. We have found, using a 900-mu-m-thick detector with 500 angstrom Pd electrodes evaporated on both surfaces (sandwich arrangement), an energy resolution equal to 600 eV at 5.9 keV X-ray (Mn-K-alpha) and 10.5 keV at 122 keV gamma-ray (Co-57).
引用
收藏
页码:455 / 463
页数:9
相关论文
共 50 条
  • [41] Highly sensitive and reliable X-ray detector with HgI2 photoconductor and oxide drive TFT
    Kim, Sun Il
    Kim, Sang Wook
    Park, Jae Chul
    Kim, Young
    Han, Sang Wook
    Kim, Ho Kyung
    Kim, Chang Jung
    Chung, U-In
    Yoo, In-Kyeong
    Kim, Kinam
    2011 IEEE INTERNATIONAL ELECTRON DEVICES MEETING (IEDM), 2011,
  • [42] PHYSICAL QUANTITIES IN GAMMA-RAY AND X-RAY DOSIMETRY USED IN RADIATION-SAFETY MONITORING
    BREGADZE, YI
    ISAEV, BM
    MASLYAEV, PF
    MEASUREMENT TECHNIQUES, 1979, 22 (08) : 998 - 1003
  • [43] MECHANISM OF X-RAY AND SOFT GAMMA-RAY RADIATION FROM ACCRETING NEUTRON STARS
    TSYGAN, AI
    ASTRONOMY & ASTROPHYSICS, 1977, 60 (01) : 39 - 42
  • [44] X-RAY AND GAMMA-RAY TOMOGRAPHY IN NDE APPLICATIONS
    GILBOY, WB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 221 (01): : 193 - 200
  • [45] Timepix detector as a tool for X-ray and gamma dosimetry
    Rubovic, Peter
    Bergmann, Benedikt
    Ekendahl, Daniela
    Hulka, Jiri
    Judas, Libor
    Kohout, Zdenek
    Pospisil, Stanislav
    Stekl, Ivan
    RADIATION MEASUREMENTS, 2017, 107 : 39 - 42
  • [46] A HARD X-RAY AND SOFT GAMMA-RAY TELESCOPE SPECTROMETER
    YIN, LI
    TROMBKA, JI
    SCHMADEBECK, RL
    SELTZER, SM
    BIELEFELD, MJ
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 268 : 97 - 102
  • [47] Development of X-ray and Gamma-ray CZT detectors for Homeland Security Applications
    Lee, Kuen
    Martin, J. W.
    Garson, A. B., III
    Beilicke, M.
    Guo, Q.
    Li, Q.
    De Geronimo, G.
    Groza, M.
    Burger, A.
    Krawczynski, H.
    DETECTION AND SENSING OF MINES, EXPLOSIVE OBJECTS, AND OBSCURED TARGETS XV, 2010, 7664
  • [48] EFFECT OF X-RAY AND gamma -RAY IRRADIATION ON THE ELECTRICAL PROPERTIES OF SOLUTION-GROWN HgI2 CRYSTALS.
    Suryanarayana, P.
    Acharya, H.N.
    1600, (06):
  • [49] Simulation and modelling of a new silicon X-ray drift detector design for synchrotron radiation applications
    Iwanczyk, JS
    Patt, BE
    Segal, J
    Plummer, J
    Vilkelis, G
    Hedman, B
    Hodgson, KO
    Cox, AD
    Rehn, L
    Metz, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2): : 288 - 294
  • [50] Simulation and modelling of a new silicon X-ray drift detector design for synchrotron radiation applications
    Iwanczyk, J.S.
    Patt, B.E.
    Segal, J.
    Plummer, J.
    Vilkelis, G.
    Hedman, B.
    Hodgson, K.O.
    Cox, A.D.
    Rehn, L.
    Metz, J.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 380 (1-2): : 288 - 294