THE REALIZATION OF A PULSATILE IMPLANTABLE IMPELLER PUMP WITH LOW HEMOLYSIS

被引:0
|
作者
QIAN, KX [1 ]
FEI, Q [1 ]
LIN, KD [1 ]
PI, KD [1 ]
WANG, YP [1 ]
机构
[1] SHANGHAI SECOND MED UNIV,INST BIOMED ENGN,SHANGHAI,PEOPLES R CHINA
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
引用
收藏
页码:330 / 330
页数:1
相关论文
共 50 条
  • [41] The balance of the impeller-driver magnet affects the antithrombogenicity in the gyro permanently implantable pump
    Ichikawa, S
    Nishimura, I
    Mikami, M
    Nonaka, K
    Linneweber, J
    Kawahito, S
    Motomura, T
    Ishitoya, H
    Glueck, J
    Shinohara, T
    Nosé, Y
    ARTIFICIAL ORGANS, 2002, 26 (11) : 927 - 930
  • [42] Investigation of Blood Hemolysis Study in Rotary Blood Pump between Continuous Flow and Pulsatile Flow
    Rungsirikunnan, Chitsanupong
    Mondee, Kamonwan
    Gesprasert, Goragoch
    Naiyanetr, Phornphop
    2018 11TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2018), 2018,
  • [43] Experimental Determination of the Normalized Index of Hemolysis for the Sputnik Implantable Pediatric Rotary Blood Pump
    Bockeria L.A.
    Bockeria O.L.
    Selishchev S.V.
    Telyshev D.V.
    Le T.G.
    Satyukova A.S.
    Shvartz V.A.
    Glushko L.A.
    Biomedical Engineering, 2017, 50 (6) : 416 - 419
  • [44] Impact of Impeller Speed Adjustment Interval on Hemolysis Performance of an Intravascular Micro-Axial Blood Pump
    Liu, Yuan
    Zhu, Yuanfei
    Wang, Shangting
    Fu, Hualin
    Lu, Zhexin
    Yang, Ming
    MICROMACHINES, 2024, 15 (07)
  • [45] Rotating cavitation in a centrifugal pump impeller of low specific speed
    Friedrichs, J
    Kosyna, G
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (02): : 356 - 362
  • [46] Centrifugal blood pump with a hydraulically-levitated impeller for a permanently implantable biventricular assist device
    Watanabe, K
    Ichikawa, S
    Asai, T
    Motomura, T
    Hata, A
    Ito, S
    Shinohara, T
    Tsujimura, S
    Glueck, JA
    Oestmann, DJ
    Nosé, Y
    ARTIFICIAL ORGANS, 2004, 28 (06) : 556 - 563
  • [47] Non-invasive flow estimation in an implantable rotary blood pump: a study considering non-pulsatile and pulsatile flows
    Ayre, PJ
    Lovell, NH
    Woodard, JC
    PHYSIOLOGICAL MEASUREMENT, 2003, 24 (01) : 179 - 189
  • [48] Pump impeller trimming
    Nurisso, DL
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1998, 40 (07): : 16 - 16
  • [49] Comparison of centrifugal and roller pump hemolysis rates at low flow
    Moon, YS
    Ohtsubo, S
    Gomez, MR
    Moon, JK
    Nose, Y
    ARTIFICIAL ORGANS, 1996, 20 (06) : 579 - 581
  • [50] DEVELOPMENT OF THE MARSEILLES PULSATILE ROTARY BLOOD PUMP FOR PERMANENT IMPLANTABLE LEFT-VENTRICULAR ASSISTANCE
    MONTIES, JR
    HAVLIK, P
    MESANA, T
    TRINKL, J
    TOURRES, JL
    DEMUNCK, JL
    ARTIFICIAL ORGANS, 1994, 18 (07) : 506 - 511