THE REALIZATION OF A PULSATILE IMPLANTABLE IMPELLER PUMP WITH LOW HEMOLYSIS

被引:0
|
作者
QIAN, KX [1 ]
FEI, Q [1 ]
LIN, KD [1 ]
PI, KD [1 ]
WANG, YP [1 ]
机构
[1] SHANGHAI SECOND MED UNIV,INST BIOMED ENGN,SHANGHAI,PEOPLES R CHINA
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
引用
收藏
页码:330 / 330
页数:1
相关论文
共 50 条
  • [21] Impeller behavior and displacement of the VentrAssist implantable rotary blood pump
    Chung, MKH
    Zhang, N
    Tansley, TD
    Woodard, JC
    ARTIFICIAL ORGANS, 2004, 28 (03) : 287 - 297
  • [22] Effects of Pulsatile Control Algorithms for Diagonal Pump on Hemodynamic Performance and Hemolysis
    Wang, Shigang
    Force, Madison
    Moroi, Morgan K.
    Patel, Sunil
    Kunselman, Allen R.
    Undar, Akif
    ARTIFICIAL ORGANS, 2019, 43 (01) : 60 - 75
  • [23] Noninvasive pulsatile flow estimation for an implantable rotary blood pump
    Karantonis, Dean M.
    Cloherty, Shaun L.
    Mason, David G.
    Ayre, Peter J.
    Lovell, Nigel H.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1018 - +
  • [24] Computational modelling and evaluation of cardiovascular response under pulsatile impeller pump support
    Shi, Yubing
    Brown, Alistair G.
    Lawford, Patricia V.
    Arndt, Andreas
    Nuesser, Peter
    Hose, D. Rodney
    INTERFACE FOCUS, 2011, 1 (03) : 320 - 337
  • [25] Design principle and animal experiments of a pulsatile centrifugal type impeller blood pump
    Qian, Kunxi
    Zheng, Ming
    Hangtian Yixue Yu Yixue Gongcheng/Space Medicine and Medical Engineering, 1996, 9 (05):
  • [26] Numerical Analysis and Hemolysis Prediction in an Implantable Aortic Valve-Pump
    Qian, Kunxi
    Wu, Qinlin
    Wang, Fangqun
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 1536 - 1539
  • [27] Development of a totally implantable pulsatile centrifugal pump as a ventricular assist device
    Chou, NK
    Wang, SS
    Lin, YH
    Shyu, TJ
    Hsieh, KH
    Jan, GJ
    Chu, SH
    ARTIFICIAL ORGANS, 2001, 25 (08) : 603 - 606
  • [28] Low flowrate effects in a centrifugal pump impeller
    Rose, MG
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2004, 218 (A6) : 417 - 427
  • [29] HYDRODYNAMIC AND HEMOLYSIS ANALYSIS ON DISTANCE AND CLEARANCE BETWEEN IMPELLER AND DIFFUSER OF AXIAL BLOOD PUMP
    Yu, Jiajia
    Zhang, Xiwen
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2016, 16 (02)
  • [30] The effect of the impeller-driver magnetic coupling distance on hemolysis in a compact centrifugal pump
    Nakazawa, T
    Makinouchi, K
    Takami, Y
    Glueck, J
    Takatani, S
    Nose, Y
    ARTIFICIAL ORGANS, 1996, 20 (03) : 252 - 257