FILM DOSIMETRY - LINEARIZATION OF DOSE-RESPONSE FOR RELATIVE MEASUREMENTS OF DOSE DISTRIBUTION

被引:7
|
作者
MOTA, HC
SIBATA, CH
ROBERTS, W
HIGGINS, PD
机构
[1] Cleveland Clinic Found., Dept. of Radiat. Therapy, Cleveland, OH
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1990年 / 35卷 / 04期
关键词
D O I
10.1088/0031-9155/35/4/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The authors have demonstrated a practical method to transform the densitometer readings to a quantity (apparent dose) that linearises the dose-response curve for the Kodak XV-2 film for all conditions used (different energies, irradiation geometries and processing). The determination of the constants for the pair film-densitometer has to be done only once, using a set of conditions chosen as reference. The linearisation method proposed permits relative film dosimetry, in the same film, without any calibration. Beam profiles (electrons or photons) obtained in several depths in a single film (parallel geometry), can be used to obtain the isodose chart, for a given field size. Only central axis depth dose data for the particular field is additionally required. Treatment plan systems can usually use these data as input to generate isodose charts.
引用
收藏
页码:565 / 569
页数:5
相关论文
共 50 条
  • [31] DOSE-RESPONSE EFFECT
    SMITH, PJ
    HINDMARSH, PC
    BROOK, CGD
    ACTA PAEDIATRICA SCANDINAVICA, 1987, : 117 - 117
  • [32] A Dose of Reality About Dose-Response Relationships
    Redelmeier, Donald A.
    Zipursky, Jonathan S.
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2023, 38 (16) : 3604 - 3609
  • [33] Dose-effect and dose-response relationship
    Bard, Denis
    Cerf, Olivier
    ENVIRONNEMENT RISQUES & SANTE, 2007, 6 (05): : 382 - 382
  • [34] Impact of dose errors on dose-response modelling
    Movik, L.
    Back, A.
    Pettersson, N.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1568 - S1569
  • [35] HUMIDITY EFFECTS ON THE DOSE-RESPONSE OF RADIACHROMIC NYLON FILM DOSIMETERS
    HUMPHERYS, KC
    RICKEY, JD
    WILCOX, RL
    RADIATION PHYSICS AND CHEMISTRY, 1990, 35 (4-6): : 713 - 715
  • [36] BIOLOGICAL DOSIMETRY USING THE MICRONUCLEUS ASSAY FOR LYMPHOCYTES - INTERINDIVIDUAL DIFFERENCES IN DOSE-RESPONSE
    THIERENS, H
    VRAL, A
    DERIDDER, L
    HEALTH PHYSICS, 1991, 61 (05): : 623 - 630
  • [37] SOME EFFECTS OF RADIATION-DOSIMETRY ERRORS ON AN ESTIMATED DOSE-RESPONSE RELATIONSHIP
    MORRIS, MD
    JONES, TD
    HEALTH PHYSICS, 1989, 56 (02): : 219 - 222
  • [38] Dose-response relationships of sulfonylureas: Will doubling the dose double the response?
    Rambiritch, Virendra
    Naidoo, Poobalan
    Butkow, Neil
    SOUTHERN MEDICAL JOURNAL, 2007, 100 (11) : 1132 - 1136
  • [39] Parameterizing Dose-Response Models to Estimate Relative Potency Functions Directly
    Dinse, Gregg E.
    Umbach, David M.
    TOXICOLOGICAL SCIENCES, 2012, 129 (02) : 447 - 455
  • [40] Absolute versus relative intensity of physical activity in a dose-response context
    Shephard, RJ
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (06): : S400 - S418