FILM DOSIMETRY - LINEARIZATION OF DOSE-RESPONSE FOR RELATIVE MEASUREMENTS OF DOSE DISTRIBUTION

被引:7
|
作者
MOTA, HC
SIBATA, CH
ROBERTS, W
HIGGINS, PD
机构
[1] Cleveland Clinic Found., Dept. of Radiat. Therapy, Cleveland, OH
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1990年 / 35卷 / 04期
关键词
D O I
10.1088/0031-9155/35/4/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The authors have demonstrated a practical method to transform the densitometer readings to a quantity (apparent dose) that linearises the dose-response curve for the Kodak XV-2 film for all conditions used (different energies, irradiation geometries and processing). The determination of the constants for the pair film-densitometer has to be done only once, using a set of conditions chosen as reference. The linearisation method proposed permits relative film dosimetry, in the same film, without any calibration. Beam profiles (electrons or photons) obtained in several depths in a single film (parallel geometry), can be used to obtain the isodose chart, for a given field size. Only central axis depth dose data for the particular field is additionally required. Treatment plan systems can usually use these data as input to generate isodose charts.
引用
收藏
页码:565 / 569
页数:5
相关论文
共 50 条
  • [1] Linearization of dose-response curve of the radiochromic film dosimetry system
    Devic, Slobodan
    Tomic, Nada
    Aldelaijan, Saad
    DeBlois, Francois
    Seuntjens, Jan
    Chan, Maria F.
    Lewis, Dave
    MEDICAL PHYSICS, 2012, 39 (08) : 4850 - 4857
  • [2] LINEARIZATION OF THE RADIOCHROMIC FILM DOSIMETRY SYSTEM DOSE RESPONSE
    Tomic, Nada
    Seuntjens, Jan
    DeBlois, Francois
    Devic, Slobodan
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S9 - S10
  • [3] THE USE OF DOSE-RESPONSE CORRECTIONS IN FILM DOSIMETRY
    HUNT, MA
    MILLER, DW
    HSI, SC
    MASTERSON, ME
    THOMASON, CL
    MEDICAL PHYSICS, 1981, 8 (04) : 575 - 575
  • [4] Linearization of Dose Response Curve for the Radiochromic Film Dosimetry System
    Lewis, D.
    Devic, S.
    Tomic, N.
    Aldelaijan, S.
    DeBlois, F.
    Chan, M.
    Seuntjens, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 4009 - 4009
  • [5] DOSE-RESPONSE CURVES AND THEIR IMPLICATIONS IN DOSIMETRY
    KARTHA, P
    CHUNGBIN, A
    WACHTOR, T
    HENDRICKSON, FR
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1977, 2 : 148 - 148
  • [6] RELATIVE DOSE-RESPONSE TEST
    RUSSELL, RM
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1985, 42 (02): : 342 - 342
  • [7] Dose-response linearization in radiochromic film dosimetry based on multichannel normalized pixel value with an integrated spectral correction for scanner response variations
    Aldelaijan, Saad
    Devic, Slobodan
    Papaconstadopoulos, Pavlos
    Bekerat, Hamed
    Cormack, Robert A.
    Seuntjens, Jan
    Buzurovic, Ivan M.
    MEDICAL PHYSICS, 2019, 46 (11) : 5336 - 5349
  • [8] THE IMPACT OF DOSIMETRY UNCERTAINTIES ON DOSE-RESPONSE ANALYSES
    Gilbert, Ethel S.
    HEALTH PHYSICS, 2009, 97 (05): : 487 - 492
  • [9] Linearization of EBT3 film dose response and virtual film dosimetry for SBRT quality assurance
    Cai, M.
    Archibald-Heeren, B.
    Wang, Y.
    Metcalfe, P.
    MICRO-MINI & NANO-DOSIMETRY & INNOVATIVE TECHNOLOGIES IN RADIATION THERAPY (MMND&ITRO2016), 2017, 777
  • [10] EXIT DOSE MEASUREMENTS BY PORTAL FILM DOSIMETRY
    FIORINO, C
    DELVECCHIO, A
    CATTANEO, GM
    FUSCA, M
    LONGOBARDI, B
    SIGNOROTTO, P
    CALANDRINO, R
    RADIOTHERAPY AND ONCOLOGY, 1993, 29 (03) : 336 - 340