CRITICAL ANATOMIC DIMENSIONS FOR INTRATHORACIC CIRCULATORY ASSIST DEVICES

被引:16
|
作者
MUSSIVAND, T [1 ]
MASTERS, RG [1 ]
HENDRY, PJ [1 ]
RAJAGOPALAN, K [1 ]
WALLEY, VM [1 ]
NAHON, D [1 ]
HICKS, A [1 ]
KEON, WJ [1 ]
机构
[1] UNIV OTTAWA,OTTAWA CIVIL HOSP,INST HEART,OTTAWA K1N 6N5,ONTARIO,CANADA
关键词
MECHANICAL CIRCULATORY SUPPORT DEVICES; CHEST CAVITY DIMENSIONS; THORAX DIMENSIONS;
D O I
10.1111/j.1525-1594.1992.tb00310.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The design of totally implantable circulatory support devices must account for the anatomical constraints of the body cavity. To aid development of an implantable electrohydraulic ventricular assist device (EVAD), thoracic anatomical measurements and fit trials were performed. Various dimensions of the thoracic cavity were measured in 19 preserved and fresh cadavers. The mean left ventricle apex to chest wall distance was 2.7 +/- 0.2 cm. The mean sagittal radius of curvature at the fifth rib was 11.1 +/- 0.4 cm, and the transverse radius at the fifth rib was 9.4 +/- 0.3 cm. The mean sternal length was 18.9 +/- 1.2 cm. Using these measurements a model measuring 17.5 x 10.5 x 3.8 cm was designed. This model was placed in the chest of 11 patients undergoing open heart surgery. In one patient there was significant lung compression and in another hypotension suggesting great vessel compression. Finally, 1 of 11 patients had a short sternum and a small thorax, and the device did not fit. In conclusion, thoracic measurements may be used in the design of circulatory support devices. The model fit adequately in 73% of patient trials.
引用
收藏
页码:281 / 285
页数:5
相关论文
共 50 条
  • [21] Mechanical circulatory assist devices: Available modalities and review of literature
    Faluk, Mohammed
    Hasan, Syed Mustajab
    Jiang, Tianyu
    Abdelmaseih, Ramy
    Patel, Jigar
    HEART VIEWS, 2020, 21 (04): : 269 - 275
  • [22] Biventricular Circulatory Support with Two Miniaturized Implantable Assist Devices
    Krabatsch, Thomas
    Potapov, Evgenij V.
    Stepanenko, Alexander
    Schweiger, Martin
    Kukucka, Marian
    Lehmkuhl, Hans B.
    Hennig, Ewald
    Hetzer, Roland
    CIRCULATION, 2010, 122 (21)
  • [23] DEVELOPMENT OF A SIMPLIFIED STIRLING ENGINE TO POWER CIRCULATORY ASSIST DEVICES
    MARTINI, WR
    JOHNSTON, RP
    GORANSON, RB
    WHITE, MA
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1968, ED15 (10) : 811 - &
  • [24] DEVELOPMENT OF A SIMPLIFIED STIRLING ENGINE TO POWER CIRCULATORY ASSIST DEVICES
    MARTINI, WR
    JOHNSTON, RP
    GORANSON, RB
    WHITE, MA
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1968, AES4 (05) : 815 - &
  • [25] Biventricular Circulatory Support With Two Miniaturized Implantable Assist Devices
    Krabatsch, Thomas
    Potapov, Evgenij
    Stepanenko, Alexander
    Schweiger, Martin
    Kukucka, Marian
    Huebler, Michael
    Hennig, Ewald
    Hetzer, Roland
    CIRCULATION, 2011, 124 (11) : S179 - S186
  • [26] USFDA perspective on regulatory issues affecting circulatory assist devices
    Sapirstein, Wolf
    Chen, Eric
    Swain, Julie
    Zuckerman, Bram
    EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (06) : 749 - 753
  • [27] General Surgery Considerations in the Era of Mechanical Circulatory Assist Devices
    Rodriguez, Limael E.
    Suarez, Erik E.
    Loebe, Matthias
    Bruckner, Brian A.
    SURGICAL CLINICS OF NORTH AMERICA, 2013, 93 (06) : 1343 - +
  • [28] Mechanical circulatory assist devices in acute and chronic heart failure
    Martin, J
    Siegenthaler, MP
    Krause, M
    Friesewinkel, O
    Beyersdorf, F
    ZENTRALBLATT FUR CHIRURGIE, 2003, 128 (10): : 796 - 803
  • [29] Circulatory Support: Artificial Muscles for the Future of Cardiovascular Assist Devices
    Pirozzi, Ileana
    Kight, Ali
    Han, Amy Kyungwon
    Cutkosky, Mark R.
    Dual, Seraina A.
    ADVANCED MATERIALS, 2024, 36 (43)
  • [30] Simulator for Modeling the Cardiovascular System for Testing Circulatory Assist Devices
    Pugovkin A.A.
    Selishchev S.V.
    Telyshev D.V.
    Biomedical Engineering, 2015, 49 (04) : 213 - 216