THE INITIAL CLINICAL-EXPERIENCE WITH AN IMPLANTABLE CARDIOVERTER DEFIBRILLATOR ANTITACHYCARDIA PACEMAKER

被引:10
|
作者
SINGER, I
AUSTIN, E
NASH, W
GILBO, J
KUPERSMITH, J
机构
[1] UNIV LOUISVILLE,DIV CARDIOTHORAC,LOUISVILLE,KY 40292
[2] TELECTR INC,ENGLEWOOD,CO
来源
关键词
IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; ANTITACHYCARDIA PACING; VENTRICULAR FIBRILLATION; VENTRICULAR TACHYCARDIA;
D O I
10.1111/j.1540-8159.1991.tb02843.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Guardian(R) antitachycardia pacing (ATP) 4210 is a third generation, multi-programmable cardioverter defibrillator undergoing Phase I clinical trials. The tiered response includes ATP, low energy cardioversion or defibrillation, and bradycardia support. Extensive telemetry is available, including an episode log and details of all episode events. Five patients underwent the implantation of Guardian(R) ATP 4210 as part of a Phase I trial at the University of Louisville. Two of the five patients had multiple VT episodes that were reverted successfully using ATP pacing (slow VT) and defibrillation (fast VT) and VF episodes, which resulted in defibrillation therapy over a follow-up period of 6 to 8 months. Four of the five patients required bradycardia support for bradyarrhythmias unassociated with ATP therapy or defibrillation and one patient required bradycardia postdefibrillation therapy. The device design is microprocessor based and requires continuous interrogation of the microprocessor memory and checks of the validity of programmed parameters to continue its operation. When the safety check fails, the device is designed to shut down its antitachycardia and defibrillator functions. This design feature has a potential for leaving the patient unprotected if the device shuts down. Modification of this feature is required to ensure the device's long-term safety.
引用
收藏
页码:1119 / 1128
页数:10
相关论文
共 50 条
  • [41] Initial experience of pacemaker and implantable cardioverter defibrillator lead extraction with the new GlideLight 80 Hz laser sheaths
    Hakmi, Samer
    Pecha, Simon
    Sill, Bjoern
    Reiter, Beate
    Willems, Stephan
    Aydin, Muhammet Ali
    Yildirim, Yalin
    Reichenspurner, Hermann
    Treede, Hendrik
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2014, 18 (01) : 56 - 60
  • [42] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - CLINICAL-EXPERIENCE, COMPLICATIONS, AND FOLLOW-UP IN 25 PATIENTS
    BORBOLA, J
    DENES, P
    EZRI, MD
    HAUSER, RG
    SERRY, C
    GOLDIN, MD
    ARCHIVES OF INTERNAL MEDICINE, 1988, 148 (01) : 70 - 76
  • [43] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR (AICD) AND ANTITACHYCARDIA PACEMAKER (TACHYLOG-651) IN THE TREATMENT OF VENTRICULAR TACHYARRHYTHMIAS
    GERCKENS, U
    MANZ, M
    FUNKE, HD
    KIRCHHOFF, PG
    LUDERITZ, B
    ZEITSCHRIFT FUR KARDIOLOGIE, 1987, 76 (04): : 211 - 216
  • [44] INITIAL CLINICAL-EXPERIENCE WITH A NEW NON-THORACOTOMY CARDIOVERTER-DEFIBRILLATOR LEAD SYSTEM
    MATTIONI, T
    RIGGIO, D
    CIRCULATION, 1994, 90 (04) : 123 - 123
  • [45] CLINICAL-EXPERIENCE WITH ANTITACHYCARDIA PACEMAKERS
    ADORNATO, E
    POLIMENI, RM
    MONEA, P
    PENNISI, V
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (03): : A26 - A26
  • [46] INITIAL CLINICAL-EXPERIENCE WITH A RATE RESPONSIVE PACEMAKER
    SINGER, I
    OLASH, J
    BRENNAN, AF
    KUPERSMITH, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (09): : 1458 - 1464
  • [47] Correlation of Geomagnetic Activity With Implantable Cardioverter Defibrillator Shocks and Antitachycardia Pacing
    Ebrille, Elisa
    Konecny, Tomas
    Konecny, Dana
    Spacek, Radim
    Jones, Paul
    Ambroz, Pavel
    DeSimone, Christopher V.
    Powell, Brian D.
    Hayes, David L.
    Friedman, Paul A.
    Asirvatham, Samuel J.
    MAYO CLINIC PROCEEDINGS, 2015, 90 (02) : 202 - 208
  • [48] Subcutaneous Implantable Cardioverter Defibrillator in Patients With Hypertrophic Cardiomyopathy: An Initial Experience
    Weinstock, Jonathan
    Bader, Yousef H.
    Maron, Martin S.
    Rowin, Ethan J.
    Link, Mark S.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (02):
  • [49] The Entirely Subcutaneous Implantable Cardioverter-Defibrillator Initial Clinical Experience in a Large Dutch Cohort
    Nordkamp, Louise R. A. Olde
    Abkenari, Lara Dabiri
    Boersma, Lucas V. A.
    Maass, Alexander H.
    de Groot, Joris R.
    van Oostrom, Antonie J. H. H. M.
    Theuns, Dominic A. M. J.
    Jordaens, Luc J. L. M.
    Wilde, Arthur A. M.
    Knops, Reinoud E.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (19) : 1933 - 1939
  • [50] A completely subcutaneous implantable cardioverter defibrillator system functioning simultaneously with an endocardial implantable cardioverter defibrillator programmed as pacemaker
    van Opstal, Jurren
    Geskes, Gijs
    Debie, Luuk
    EUROPACE, 2011, 13 (01): : 141 - 142