DIRECT BIOELECTROCATALYTIC REDUCTION OF HYDROGEN-PEROXIDE AT CHLOROPEROXIDASE MODIFIED GRAPHITE ELECTRODE

被引:18
|
作者
RUZGAS, T [1 ]
GORTON, L [1 ]
EMNEUS, J [1 ]
CSOREGI, E [1 ]
MARKOVARGA, G [1 ]
机构
[1] LUND UNIV,DEPT ANALYT CHEM,S-22100 LUND,SWEDEN
来源
ANALYTICAL PROCEEDINGS | 1995年 / 32卷 / 06期
关键词
D O I
10.1039/ai9953200207
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electroreduction of hydrogen peroxide was studied at a chloroperoxidase-modified graphite electrode. The reduction of H2O2 starts at more negative potentials than 0.45 V versus SCE at pH 7.0. The steady-state reduction currents are greater at acidic pH values, and in the presence of chloride ions in solution. The apparent Michaelis-Menten constant and sensitivity were evaluated to be equal to 105 mu mol l(-1) and 1.3 mA l mol(-1) for the electrode responses to the H2O2 in 0.1 mol l(-1) phosphate buffer solution free of chloride ions. On the basis of these results direct electron transfer is postulated between the active site of chloroperoxidase and the graphite electrode.
引用
收藏
页码:207 / 208
页数:2
相关论文
共 50 条
  • [31] PEROXIDASE FERROCENE MODIFIED CARBON PASTE ELECTRODE AS AN AMPEROMETRIC SENSOR FOR THE HYDROGEN-PEROXIDE ASSAY
    SANCHEZ, PD
    ORDIERES, AJM
    GARCIA, AC
    BLANCO, PT
    ELECTROANALYSIS, 1991, 3 (4-5) : 281 - 285
  • [32] Amperometric determination of hydrogen peroxide by direct and catalytic reduction at a copper electrode
    Somasundrum, M
    Kirtikara, K
    Tanticharoen, M
    ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) : 59 - 70
  • [33] Chemically modified electrode for hydrogen peroxide measurement by reduction at low potential
    Mulchandani, A
    Barrows, LC
    BIOSENSOR AND CHEMICAL SENSOR TECHNOLOGY: PROCESS MONITORING AND CONTROL, 1995, 613 : 61 - 69
  • [34] INVESTIGATION OF THE RADIATION EMITTED BY ANSI ELECTRODE IN THE IR REGION DURING CATHODIC REDUCTION OF HYDROGEN AND HYDROGEN-PEROXIDE
    TYAGAI, VA
    GORADYSKII, AV
    DOGONADZE, RR
    KOLBASOV, LY
    SOVIET ELECTROCHEMISTRY, 1981, 17 (02): : 263 - 266
  • [35] TTF-MODIFIED BIOSENSORS FOR HYDROGEN-PEROXIDE
    BIFULCO, L
    CAMMAROTO, C
    NEWMAN, JD
    TURNER, APF
    ANALYTICAL LETTERS, 1994, 27 (08) : 1443 - 1452
  • [36] Ionic liquid modified GC electrode for the direct electrochemistry of chloroperoxidase
    Liu Yang Xia Qin Wu Rong Wang Zhong Qing Lu Wen Jing Hou He Xing Li Life and Environment Science College
    Chinese Chemical Letters, 2008, 19 (12) : 1483 - 1486
  • [37] PRODUCTION OF HYDROGEN-PEROXIDE BY CATHODIC REDUCTION OF OXYGEN
    KASTENING, B
    FAUL, W
    CHEMIE INGENIEUR TECHNIK, 1977, 49 (11) : 911 - 911
  • [38] ELECTROCHEMICAL PRODUCTION OF HYDROGEN-PEROXIDE BY REDUCTION OF OXYGEN
    SUDOH, M
    KITAGUCHI, H
    KOIDE, K
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1985, 18 (05) : 409 - 414
  • [39] AN INVESTIGATION OF HYDROGEN-PEROXIDE REDUCTION AND DECOMPOSITION CATALYSTS
    KICHEEV, AG
    KALMYKOVA, SB
    KVASHNIN, YA
    SAVELEVA, VN
    MAKSIMOV, GN
    SOVIET ELECTROCHEMISTRY, 1985, 21 (07): : 846 - 849
  • [40] Ionic liquid modified GC electrode for the direct electrochemistry of chloroperoxidase
    Yang, Liu
    Wu, Xia Qin
    Wang, Rong
    Lu, Zhong Qing
    Hou, Wen Jing
    Li, He Xing
    CHINESE CHEMICAL LETTERS, 2008, 19 (12) : 1483 - 1486