Amperometric determination of hydrogen peroxide by direct and catalytic reduction at a copper electrode

被引:88
|
作者
Somasundrum, M
Kirtikara, K
Tanticharoen, M
机构
[1] KING MONGKUTS INST TECHNOL,SCH ELECT ENGN,BANGKOK 10140,THAILAND
[2] NATL CTR GENET ENGN & BIOTECHNOL,BANGKOK 10400,THAILAND
关键词
amperometry; catalytic methods; hydrogen peroxide;
D O I
10.1016/0003-2670(95)00473-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In a buffer solution at ambient temperature and dissolved oxygen concentration, pH 6.7, copper electrodes could be cycled between the Cu(O)/Cu(II) redox states, by cycling the potential between -0.8 and + 0.3 V vs. SCE. At 1 V s(-1), the reduction of Cu(II) proceeded with a rate constant of 12.3 s(-1) (alpha(C) = 0.16, alpha(A) = 0.93). The redox couple catalysed the reduction of hydrogen peroxide, with a second-order rate constant of approx. 25 +/- 10 M(-1) s(-1). Amperometric determination of H2O2 at - 0.25 V gave a limit of detection (2 X noise) of 1.2 mu M (sensitivity = 0.211 mA mM(-1) cm(-2) up to 2.0 mM), with a response time (steady-state) of 3 to 4 s. A 1 mu M change in the O-2 concentration gave approx. a 0.04% change in the H2O2 sensitivity. The presence of H2O-soluble copper-complexing anions at low concentrations gave a change in the H2O2 response. At higher anion concentrations (>20 mM), the rate of electron transfer from the metal was faster than the rate of Cu(II) dissolution. A copper micro-band electrode was used to determine H2O2 in a mixture of glacial acetic acid and chloroform.
引用
收藏
页码:59 / 70
页数:12
相关论文
共 50 条
  • [1] NEW CATALYTIC ELECTRODE FOR THE AMPEROMETRIC DETERMINATION OF HYDROGEN-PEROXIDE
    IWASE, A
    KUDO, S
    TANAKA, N
    ANALYTICA CHIMICA ACTA, 1979, 110 (01) : 157 - 160
  • [2] AMPEROMETRIC DETERMINATION OF MOLYBDENUM(VI) BY CATALYTIC CURRENT OF REDUCTION OF HYDROGEN-PEROXIDE
    SHARIPOV.NS
    SONGINA, OA
    ZHURNAL ANALITICHESKOI KHIMII, 1973, 28 (12): : 2348 - 2351
  • [3] Amperometric determination of hydrogen peroxide using a copper microelectrode
    Dantas, L. M. F.
    Castro, P. S.
    Pena, R. C.
    Bertotti, M.
    ANALYTICAL METHODS, 2014, 6 (07) : 2112 - 2116
  • [4] Electrocatalytic reduction of hydrogen peroxide at nanostructured copper modified electrode
    Selvaraju, Thangavelu
    Ramaraj, Ramasamy
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (03) : 321 - 327
  • [5] Electrocatalytic reduction of hydrogen peroxide at nanostructured copper modified electrode
    Thangavelu Selvaraju
    Ramasamy Ramaraj
    Journal of Applied Electrochemistry, 2009, 39 : 321 - 327
  • [6] Electrocatalytic reduction of hydrogen peroxide at nanostructured copper modified electrode
    Selvaraju, Thangavelu
    Ramaraj, Ramasamy
    Journal of Applied Electrochemistry, 2009, 39 (03): : 321 - 327
  • [7] Amperometric sensing of hydrogen peroxide using glassy carbon electrode modified with copper nanoparticles
    Sophia, J.
    Muralidharan, G.
    MATERIALS RESEARCH BULLETIN, 2015, 70 : 315 - 320
  • [8] Selective amperometric sensing of hydrogen peroxide with Nafion/copper particulates chemically modified electrode
    Kumar, Annamalai Senthil
    Sornambikai, Sundaram
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2009, 48 (07): : 940 - 945
  • [9] Direct electrocatalytic reduction of hydrogen peroxide based on Nafion and copper oxide nanoparticles modified Pt electrode
    Miao, Xiang-Min
    Yuan, Ruo
    Chai, Ya-Qin
    Shi, Yin-Tao
    Yuan, Yan-Yu
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 612 (02) : 157 - 163
  • [10] Methylene Blue/Multiwall Carbon Nanotube Modified Electrode for the Amperometric Determination of Hydrogen Peroxide
    Pena, Roselyn C.
    Bertotti, Mauro
    Brett, Christopher M. A.
    ELECTROANALYSIS, 2011, 23 (10) : 2290 - 2296