Amperometric determination of hydrogen peroxide by direct and catalytic reduction at a copper electrode

被引:88
|
作者
Somasundrum, M
Kirtikara, K
Tanticharoen, M
机构
[1] KING MONGKUTS INST TECHNOL,SCH ELECT ENGN,BANGKOK 10140,THAILAND
[2] NATL CTR GENET ENGN & BIOTECHNOL,BANGKOK 10400,THAILAND
关键词
amperometry; catalytic methods; hydrogen peroxide;
D O I
10.1016/0003-2670(95)00473-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In a buffer solution at ambient temperature and dissolved oxygen concentration, pH 6.7, copper electrodes could be cycled between the Cu(O)/Cu(II) redox states, by cycling the potential between -0.8 and + 0.3 V vs. SCE. At 1 V s(-1), the reduction of Cu(II) proceeded with a rate constant of 12.3 s(-1) (alpha(C) = 0.16, alpha(A) = 0.93). The redox couple catalysed the reduction of hydrogen peroxide, with a second-order rate constant of approx. 25 +/- 10 M(-1) s(-1). Amperometric determination of H2O2 at - 0.25 V gave a limit of detection (2 X noise) of 1.2 mu M (sensitivity = 0.211 mA mM(-1) cm(-2) up to 2.0 mM), with a response time (steady-state) of 3 to 4 s. A 1 mu M change in the O-2 concentration gave approx. a 0.04% change in the H2O2 sensitivity. The presence of H2O-soluble copper-complexing anions at low concentrations gave a change in the H2O2 response. At higher anion concentrations (>20 mM), the rate of electron transfer from the metal was faster than the rate of Cu(II) dissolution. A copper micro-band electrode was used to determine H2O2 in a mixture of glacial acetic acid and chloroform.
引用
收藏
页码:59 / 70
页数:12
相关论文
共 50 条
  • [21] Amperometric Determination of Hydrogen Peroxide in Whitening Gels Using Boron-doped Diamond Electrode
    Gustavo C. Azevedo
    Roberto H. S. Castro
    Maria Auxiliadora C. Matos
    Renato Camargo Matos
    Analytical Sciences, 2018, 34 : 913 - 917
  • [22] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    An’amt Mohamed Noor
    Muhammad Mehmood Shahid
    Perumal Rameshkumar
    Nay Ming Huang
    Microchimica Acta, 2016, 183 : 911 - 916
  • [23] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF HYDROGEN-PEROXIDE BY OXIDATION AT AN IRIDIUM OXIDE ELECTRODE
    COX, JA
    LEWINSKI, K
    TALANTA, 1993, 40 (12) : 1911 - 1915
  • [24] Poly(Celestine Blue)-Graphene Oxide Nanohybrid Modified Electrode for Amperometric Determination of Hydrogen Peroxide
    Sangeetha, N. S.
    Ramaprabhu, Sundara
    Narayanan, S. Sriman
    GRAPHENE, 2013, 1 (02) : 136 - 141
  • [25] THE CONSTITUTION OF COPPER PEROXIDE AND THE CATALYTIC DECOMPOSITION OF HYDROGEN PEROXIDE
    GLASNER, A
    JOURNAL OF THE CHEMICAL SOCIETY, 1951, (APR): : 904 - 910
  • [26] DIRECT BIOELECTROCATALYTIC REDUCTION OF HYDROGEN-PEROXIDE AT CHLOROPEROXIDASE MODIFIED GRAPHITE ELECTRODE
    RUZGAS, T
    GORTON, L
    EMNEUS, J
    CSOREGI, E
    MARKOVARGA, G
    ANALYTICAL PROCEEDINGS, 1995, 32 (06): : 207 - 208
  • [27] Voltammetric determination of hydrogen peroxide at high concentration level using a copper electrode
    Terzi, F.
    Zanfrognini, B.
    Dossi, N.
    Ruggeri, S.
    Maccaferri, G.
    ELECTROCHIMICA ACTA, 2016, 188 : 327 - 335
  • [28] CATALYTIC DETERMINATION OF HYDROGEN-PEROXIDE
    STRELTSOVA, ED
    SMIRNOVA, EB
    DOLMANOVA, IF
    VESTNIK MOSKOVSKOGO UNIVERSITETA SERIYA 2 KHIMIYA, 1989, 30 (05): : 482 - 486
  • [29] Determination of copper by its catalytic effect on the oxidation of hydroquinone by hydrogen peroxide on supports
    Yu. Yu. Petrova
    M. K. Beklemishev
    N. A. Bazhanova
    A. A. Druzhinin
    I. F. Dolmanova
    Journal of Analytical Chemistry, 2000, 55 : 284 - 290
  • [30] Determination of copper by its catalytic effect on the oxidation of hydroquinone by hydrogen peroxide on supports
    Petrova, YY
    Beklemishev, MK
    Bazhanova, NA
    Druzhinin, AA
    Dolmanova, IF
    JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 55 (03) : 284 - 290