METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS

被引:0
|
作者
Suprunovska, N., I [1 ]
Shcherba, M. A. [1 ]
机构
[1] NAS Ukraine, Inst Electrodynam, 56 Prospekt Peremogy, UA-03057 Kiev, Ukraine
关键词
electric discharge installation; capacitor charge; charge voltage; transients; nonzero initial conditions;
D O I
10.20998/2074-272X.2018.5.07
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Purpose. To analyze the transient processes in the charge circuit of electric discharge installations with two capacitors, taking into account the change in the initial conditions of such processes (initial voltage on the capacitors and the initial current in the charge circuit) as well as to develop the method for charge voltage control of such installations using purposeful change of these initial conditions. Methodology. We have applied the concepts of theoretical electrical engineering, the principles of theory of electrical circuits, and mathematical simulation in the software package MathCAD 12. Results. We have obtained analytical expressions and graphical dependencies establishing a quantitative relationship between the value of the maximum charge voltage of an electric discharge installation and the values of the initial voltage on its capacitors and the initial current in the circuit. This allows us to propose the method for the charge voltage control of electric discharge installations with two reservoir capacitors, using a purposeful change in their initial voltages and initial current in the charge circuit Originality. For the first time, we have found that the charge voltage of the installation can be controlled using two influence mechanisms - either changing the initial current in the charge circuit (by interrupting the transient process of the first capacitor charge at a certain time) or using a nonzero initial voltage on the charged second capacitor. In this case the charge voltage can be varied by 2 times. Practical value. The use of this method makes it possible to obtain discharge pulses of complex shape in the technological load, since the maximum charge voltages of the first capacitor and second one can differ by a factor of 1.5.
引用
收藏
页码:39 / 43
页数:5
相关论文
共 50 条
  • [41] Control Method for Overvoltage Suppression Across the DC Capacitor in a Grid-Connection Converter Using Leg Short Circuit of Power MOSFETs during the Initial Charge
    Mannen, Tomoyuki
    Wada, Keiji
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (04) : 4012 - 4019
  • [42] Study on the total electric field at the ground level under two circuit DC transmission lines in the same corridor based on the upstream FEM method
    Yang, Yang
    Yang, Yong
    Lu, Jiayu
    PEAM 2011 - Proceedings: 2011 IEEE Power Engineering and Automation Conference, 2011, 2 : 14 - 17
  • [43] A novel method for constructing the relationships between state of charge and open-circuit voltage of lithium-ion battery under different temperatures with reduced test time
    Chen, Guisheng
    Xu, Yangsong
    Li, Junda
    Shen, Yinggang
    Xiao, Renxin
    Ba, Tingjie
    Liu, Qiang
    JOURNAL OF CLEANER PRODUCTION, 2023, 428
  • [44] A Control Method of Overvoltage Suppression across the DC Capacitor in a Grid-Connection Converter Using Leg Short-Circuit of Power MOSFETs during the Initial Charge
    Mannen, Tomoyuki
    Wada, Keiji
    2018 INTERNATIONAL POWER ELECTRONICS CONFERENCE (IPEC-NIIGATA 2018 -ECCE ASIA), 2018, : 1866 - 1871
  • [45] A Novel Control Method for Unified Power Quality Conditioner (UPQC) Under Non-Ideal Mains Voltage and Unbalanced Load Conditions
    Kesler, Metin
    Ozdemir, Engin
    2010 TWENTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2010, : 374 - 379
  • [46] PR Control for Two-Stage Matrix Converter Excitation Doubly Fed Wind Generation System Under Unbalanced Grid Voltage Conditions
    Wang, Junrui
    Zhong, Yanru
    Song, Weizhang
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [47] Improved voltage control method of power system based on doubly fed wind farm considering power coupling under grid short-circuit fault
    Ouyang, Jinxin
    Pang, Mingyu
    Zheng, Di
    Yuan, Yifeng
    Diao, Yanbo
    IET RENEWABLE POWER GENERATION, 2020, 14 (13) : 2429 - 2436
  • [48] Control of three-phase grid connected converter based on harmonic power injection method under the non-ideal grid voltage conditions
    Zhou X.
    Chen H.
    Xu H.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2016, 36 (01): : 215 - 223
  • [49] A novel control concept for operating a two-stage Δ-rectifier-based telecommunications power supply module under heavily unbalanced mains voltage conditions
    Miniböck, J
    Greul, R
    Kolar, JW
    APEC 2002: SEVENTEENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1 AND 23, 2002, : 716 - 721
  • [50] ITIES electric voltage in open circuit, treated as "Mixed potential".: III.: Simultaneous transfer through ITIES, unaffected by diffusion of two ions having the same charge gmITIES and im expressions in constants dependent on the potential
    Mihailciuc, C
    REVISTA DE CHIMIE, 2000, 51 (05): : 359 - 364