METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS

被引:0
|
作者
Suprunovska, N., I [1 ]
Shcherba, M. A. [1 ]
机构
[1] NAS Ukraine, Inst Electrodynam, 56 Prospekt Peremogy, UA-03057 Kiev, Ukraine
关键词
electric discharge installation; capacitor charge; charge voltage; transients; nonzero initial conditions;
D O I
10.20998/2074-272X.2018.5.07
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Purpose. To analyze the transient processes in the charge circuit of electric discharge installations with two capacitors, taking into account the change in the initial conditions of such processes (initial voltage on the capacitors and the initial current in the charge circuit) as well as to develop the method for charge voltage control of such installations using purposeful change of these initial conditions. Methodology. We have applied the concepts of theoretical electrical engineering, the principles of theory of electrical circuits, and mathematical simulation in the software package MathCAD 12. Results. We have obtained analytical expressions and graphical dependencies establishing a quantitative relationship between the value of the maximum charge voltage of an electric discharge installation and the values of the initial voltage on its capacitors and the initial current in the circuit. This allows us to propose the method for the charge voltage control of electric discharge installations with two reservoir capacitors, using a purposeful change in their initial voltages and initial current in the charge circuit Originality. For the first time, we have found that the charge voltage of the installation can be controlled using two influence mechanisms - either changing the initial current in the charge circuit (by interrupting the transient process of the first capacitor charge at a certain time) or using a nonzero initial voltage on the charged second capacitor. In this case the charge voltage can be varied by 2 times. Practical value. The use of this method makes it possible to obtain discharge pulses of complex shape in the technological load, since the maximum charge voltages of the first capacitor and second one can differ by a factor of 1.5.
引用
收藏
页码:39 / 43
页数:5
相关论文
共 50 条
  • [21] A Control Strategy for a Matrix Converter Based on Venturini Method Under Unbalanced Input Voltage Conditions
    Boonseam, Pornpimol
    Jarutus, Neerakorn
    Kumsuwan, Yuttana
    2016 13TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2016,
  • [22] Control Strategy of Electric Spring Under Non-ideal Voltage Conditions Based on Improved PSO Algorithm
    Zhou J.
    Li X.
    Mao D.
    Li H.
    Deng Y.
    Hu C.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2018, 42 (22): : 165 - 171
  • [23] Partial Discharge Automatic Locating Algorithm for Cable under Oscillatory Wave Voltage Conditions Based on Traveling Wave Method
    Zhang R.
    Chen Z.
    Du G.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (04): : 1289 - 1296
  • [24] Efficiency of some optimisation approaches with the charge simulation method for calculating the electric field under extra high voltage power lines
    Rabah, Djekidel
    Abdelghani, Choucha
    Abdelchafik, Hadjaj
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (17) : 4167 - 4174
  • [25] Electric and Mechanical Brake Cooperative Control Method for FRID EVs under Various Severe Road Conditions
    Mutoh, Nobuyoshi
    Akashi, Hiroyuki
    IECON 2011: 37TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2011,
  • [26] Partial Discharge Initial Characteristics of SF6/N2 Mixture in Extremely Inhomogeneous Electric Field under DC High Voltage
    Pang P.
    Sun Z.
    Zhang Q.
    Hou Z.
    Zhang X.
    Sun S.
    Li J.
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2019, 53 (04): : 44 - 50
  • [27] Control method for DC-link voltage ripple cancellation in voltage source inverter under unbalanced three-phase voltage supply conditions
    Chomat, M
    Schreier, L
    IEEE IEMDC'03: IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, VOLS 1-3, 2003, : 869 - 875
  • [28] Control method for DC-link voltage ripple cancellation in voltage source inverter under unbalanced three-phase voltage supply conditions
    Chomat, M
    Schreier, L
    IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2005, 152 (03): : 494 - 500
  • [29] Application of the Method of Generalized Functions to the Investigation of Transient Processes in an Electric Drive under Non-Zero Initial Conditions.
    Ankhimyuk, V.L.
    Karaul'naya, L.F.
    Novitskaya, V.A.
    Izvestiya Vysshikh Uchebnykh Zavedenij i Energeticheskikh Ob''edinenij Sng. Energetika, 1976, (08): : 51 - 56
  • [30] Computation of electric field induced currents on human body standing under a high voltage transmission line by using charge simulation method
    Yildirim, H
    Kalenderli, O
    PROCEEDINGS OF THE 1998 2ND INTERNATIONAL CONFERENCE BIOMEDICAL ENGINEERING DAYS, 1998, : 75 - 77