Determination of acrylamide in processed foods by column-switching HPLC with UV detection

被引:12
|
作者
Terada, H [1 ]
Tamura, Y [1 ]
机构
[1] Nagoya City Publ Hlth Res Inst, Mizuho Ku, Nagoya, Aichi 4678615, Japan
来源
JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN | 2003年 / 44卷 / 06期
关键词
acrylamide; HPLC; column switching; aqueous gel permeation column; UV detector; processed food;
D O I
10.3358/shokueishi.44.303
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A simple and convenient analytical method for the determination of acrylamide in processed foods was established. Acrylamide was extracted with water in an ultrasonic bath. The extract was passed through an OASIS HLB cartridge and the eluate was injected into the HPLC system using a column-switching technique. The HPLC system consisted of two pumps, two 6-port-2-position valves, two columns and a UV detector. At first, the sample solution was chromatographed on an ODS column with a mobile phase of water, then the flow of the mobile phase was switched using a 6-port-2-position valve, and the acrylamide peak fraction was introduced into an aqueous gel permeation column (analytical column). The fraction was chromatographed again on the analytical column with a mobile phase of water, and the eluate was monitored with a UV detector (205 nm). The recoveries of acrylamide from potato chips, fried potato, croquette and instant noodle fortified at levels of 50 to 1,000 mug/kg were 93.1 to 101.5% and the coefficient of variation was 1.5 to 5.2%. The detection limit corresponded to 10 mug/kg in processed foods. Forty-six samples, potato chips (11), fried potato (10), croquette (20) and instant noodle (5), were analyzed by this method. The acrylamide level was 67-4,499 mug/kg for potato chips, 1251,183 mug/kg for fried potato, nd-255 mug/kg for croquette and nd-151 mug/kg for instant noodle.
引用
收藏
页码:303 / 309
页数:7
相关论文
共 50 条
  • [41] Determination of ammonium in seawater by column-switching ion chromatography
    Huang, Y
    Mou, S
    Riviello, JM
    JOURNAL OF CHROMATOGRAPHY A, 2000, 868 (02) : 209 - 216
  • [42] Determination of Acrylamide in Starch-Based Foods by HPLC with Pre-Column Ultraviolet Derivatization
    Geng, Zhiming
    Wang, Peng
    Liu, Aiming
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2011, 49 (10) : 818 - 824
  • [43] A generic method for the determination of acrylamide in thermally processed foods
    Gokmen, Vural
    Senyuva, Hamide Z.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1120 (1-2) : 194 - 198
  • [44] Determination of Drugs by Online Column-Switching Liquid Chromatography
    Andac, Sena Caglar
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2016, 54 (09) : 1641 - 1647
  • [45] Simultaneous determination of gizzerosine and histamine in chicken tissues by HPLC using an on-column fluorescence derivatization and column-switching technique
    Saito, K
    Horie, M
    Tokumaru, Y
    Hattori, S
    Nakazawa, H
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 1998, 39 (01): : 39 - 41
  • [46] Determination of Biogenic Amines in Fish Meat and Fermented Foods Using Column-Switching High-Performance Liquid Chromatography with Fluorescence Detection
    Ishimaru, Mami
    Muto, Yuma
    Nakayama, Akari
    Hatate, Hideo
    Tanaka, Ryusuke
    FOOD ANALYTICAL METHODS, 2019, 12 (01) : 166 - 175
  • [47] Determination of Biogenic Amines in Fish Meat and Fermented Foods Using Column-Switching High-Performance Liquid Chromatography with Fluorescence Detection
    Mami Ishimaru
    Yuma Muto
    Akari Nakayama
    Hideo Hatate
    Ryusuke Tanaka
    Food Analytical Methods, 2019, 12 : 166 - 175
  • [48] Chemo-affinity of Titania for the Column-switching HPLC Analysis of Phosphopeptides
    Akira Sano
    Hiroshi Nakamura
    Analytical Sciences, 2004, 20 : 565 - 566
  • [49] Characterization of insulin-loaded liposome using column-switching HPLC
    Ohnishi, Naozumi
    Tanaka, Shota
    Tahara, Kohei
    Takeuchi, Hirofumi
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2015, 479 (02) : 302 - 305
  • [50] Determination of Acrylamide in Starchy Foods by RP-HPLC
    Wei, Yongchun
    Xiong, Zhiyong
    INTERNATIONAL JOURNAL OF MULTIPHYSICS, 2024, 18 (02) : 169 - 174