Determination of acrylamide in processed foods by column-switching HPLC with UV detection

被引:12
|
作者
Terada, H [1 ]
Tamura, Y [1 ]
机构
[1] Nagoya City Publ Hlth Res Inst, Mizuho Ku, Nagoya, Aichi 4678615, Japan
来源
JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN | 2003年 / 44卷 / 06期
关键词
acrylamide; HPLC; column switching; aqueous gel permeation column; UV detector; processed food;
D O I
10.3358/shokueishi.44.303
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A simple and convenient analytical method for the determination of acrylamide in processed foods was established. Acrylamide was extracted with water in an ultrasonic bath. The extract was passed through an OASIS HLB cartridge and the eluate was injected into the HPLC system using a column-switching technique. The HPLC system consisted of two pumps, two 6-port-2-position valves, two columns and a UV detector. At first, the sample solution was chromatographed on an ODS column with a mobile phase of water, then the flow of the mobile phase was switched using a 6-port-2-position valve, and the acrylamide peak fraction was introduced into an aqueous gel permeation column (analytical column). The fraction was chromatographed again on the analytical column with a mobile phase of water, and the eluate was monitored with a UV detector (205 nm). The recoveries of acrylamide from potato chips, fried potato, croquette and instant noodle fortified at levels of 50 to 1,000 mug/kg were 93.1 to 101.5% and the coefficient of variation was 1.5 to 5.2%. The detection limit corresponded to 10 mug/kg in processed foods. Forty-six samples, potato chips (11), fried potato (10), croquette (20) and instant noodle (5), were analyzed by this method. The acrylamide level was 67-4,499 mug/kg for potato chips, 1251,183 mug/kg for fried potato, nd-255 mug/kg for croquette and nd-151 mug/kg for instant noodle.
引用
收藏
页码:303 / 309
页数:7
相关论文
共 50 条
  • [31] BAND-BROADENING EFFECTS IN A COLUMN-SWITCHING SYSTEM FOR HPLC
    DOLPHIN, RJ
    WILLMOTT, FW
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1976, 14 (12) : 584 - 588
  • [32] Application of Column-Switching Methods in HPLC for Evaluating Pharmacokinetic Parameters
    Lee, Hwa Jeong
    Kim, Kyu-Bong
    ADVANCES IN CHROMATOGRAPHY, VOL 49, 2011, 49 : 291 - 340
  • [34] SIMULTANEOUS DETERMINATION OF CEFOXITIN, CEFUROXIME, CEPHALEXIN AND CEPHALORIDINE IN PLASMA USING HPLC AND A COLUMN-SWITCHING TECHNIQUE
    LEE, YJ
    LEE, HS
    CHROMATOGRAPHIA, 1990, 30 (1-2) : 80 - 84
  • [35] Automated Determination of Sulfadiazine in Water, Fish Plasma and Muscle by HPLC with On-Line Column-Switching
    Altunok, Muhammet
    Koenig, Armin
    Ahmed, Waleed M. M. Mahmoud
    Haddad, Tarek
    Vasconcelos, Tibirica G.
    Kuemmerer, Klaus
    CLEAN-SOIL AIR WATER, 2016, 44 (08) : 967 - 974
  • [36] APPLICATION OF HPLC COLUMN-SWITCHING IN PESTICIDE-RESIDUE ANALYSIS
    HOGENDOORN, EA
    GOEWIE, CE
    VANZOONEN, P
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (06): : 348 - 356
  • [37] AUTOMATED ONLINE DIALYSIS AND COLUMN-SWITCHING HPLC DETERMINATION OF FLUMEQUINE AND OXOLINIC ACID IN FISH LIVER
    ANDRESEN, AT
    RASMUSSEN, KE
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (20): : 4051 - 4065
  • [38] DETERMINATION OF CEFPODOXIME LEVELS AND CEFPODOXIME STABILITY IN HUMAN URINE BY DIRECT INJECTION HPLC WITH COLUMN-SWITCHING
    BOMBARDT, PA
    CATHCART, KS
    BOTHWELL, BE
    CLOSSON, SK
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1991, 14 (09): : 1729 - 1746
  • [39] Automated determination of ziprasidone by HPLC with column switching and spectrophotometric detection
    Sachse, J
    Härtter, S
    Hiemke, C
    THERAPEUTIC DRUG MONITORING, 2005, 27 (02) : 158 - 162
  • [40] Fluorescence determination of acrylamide in heat-processed foods
    Liu, Congcong
    Luo, Feng
    Chen, Dongmei
    Qiu, Bin
    Tang, Xinhua
    Ke, Huixian
    Chen, Xi
    TALANTA, 2014, 123 : 95 - 100