CYCLOTRON AUTORESONANCE MASER WITH HIGH DOPPLER FREQUENCY UP-CONVERSION

被引:9
|
作者
BRATMAN, VL [1 ]
DENISOV, GG [1 ]
OFITSEROV, MM [1 ]
SAMSONOV, SV [1 ]
ARKHIPOV, OV [1 ]
KAZACHA, VI [1 ]
KRASNYKH, AK [1 ]
PERELSTEIN, EA [1 ]
ZAMRIJ, AV [1 ]
机构
[1] JOINT INST NUCL RES,DUBNA 141980,USSR
来源
INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES | 1992年 / 13卷 / 12期
关键词
CYCLOTRON AUTORESONANCE MASER; FREE ELECTRON MASER; BRAGG REFLECTION RESONATOR; LINEAR INDUCTION ACCELERATOR;
D O I
10.1007/BF01011327
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An LIA-unit with explosive emission injector was used as a basis for CARM with high Doppler frequency up-conversion when the wave frequency is 7 to 9 times the cyclotron frequency of electrons. Using a high-selectivity Bragg resonator as an electrodynamic system of CARM we investigated two regimes having essentially different properties: the dispersion characteristics of the electron beam and the wave either intersected or were tangential to one another. In the first case, the radiation power amounted to 50 MW at the wavelength of 4.4 mm with efficiency 8 %. The efficiency significantly smaller than the design value was evidently caused by a high level of parasitic superluminiscence of the beam. In the second regime of operation at 6 mm, the radiation power was 30 MW with a low level of parasitic superluminiscence and efficiency 10 % which was close to the calculated value.
引用
收藏
页码:1857 / 1873
页数:17
相关论文
共 50 条
  • [41] INFRARED DETECTION BY PARAMETRIC FREQUENCY UP-CONVERSION
    JOHNSON, FM
    DUARDO, JA
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1966, QE 2 (08) : 296 - &
  • [42] Frequency Up-Conversion of an Even Coherent State
    Belinsky A.V.
    Singh R.
    Bulletin of the Russian Academy of Sciences: Physics, 2024, 88 (01) : 30 - 32
  • [43] Enhanced frequency up-conversion in Rb vapor
    Vernier, A.
    Franke-Arnold, S.
    Riis, E.
    Arnold, A. S.
    OPTICS EXPRESS, 2010, 18 (16): : 17020 - 17026
  • [44] Nonlinear Simulation of a Cyclotron Autoresonance Maser (CARM) Operating in a Transverse Magnetic Mode
    Liu, Bing-Fu
    Zhang, Shi-Chang
    JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2011, 32 (01) : 8 - 15
  • [45] Linear Analysis of a Cyclotron Autoresonance Maser (CARM) Operating in a Transverse Magnetic Mode
    Na Yang
    Shi-Chang Zhang
    Journal of Infrared, Millimeter, and Terahertz Waves, 2009, 30 : 328 - 336
  • [46] Modified self-consistent nonlinear simulation of cyclotron autoresonance maser amplifiers
    Dawn, TY
    Chien, HC
    Chen, JM
    Chen, SH
    PHYSICS OF PLASMAS, 1998, 5 (02) : 529 - 535
  • [47] Linear and nonlinear investigation of a coaxial-waveguide cyclotron autoresonance maser amplifier
    Zhang, SC
    PHYSICS OF PLASMAS, 2004, 11 (08) : 3969 - 3975
  • [48] Nonlinear Simulation of a Cyclotron Autoresonance Maser (CARM) Operating in a Transverse Magnetic Mode
    Bing-Fu Liu
    Shi-Chang Zhang
    Journal of Infrared, Millimeter, and Terahertz Waves, 2011, 32 : 8 - 15
  • [49] Nonlinear Multimode Interaction in a Higher-Order-Mode Cyclotron Autoresonance Maser
    Chai, Bin
    Zhang, Shi-Chang
    2011 36TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2011,
  • [50] EFFICIENCY DEPENDENCE ON BEAM CURRENT AND INPUT POWER IN A CYCLOTRON AUTORESONANCE MASER AMPLIFIER
    KHO, TH
    LIN, AT
    PHYSICS OF FLUIDS B-PLASMA PHYSICS, 1990, 2 (04): : 822 - 827