A DISPOSABLE END-TIDAL CO2 DETECTOR TO VERIFY ENDOTRACHEAL INTUBATION

被引:55
|
作者
ANTON, WR
GORDON, RW
JORDAN, TM
POSNER, KL
CHENEY, FW
机构
[1] Respiratory Care Services, University of Washington Medical Center, Seattle
[2] Department of Anesthesiology, University of Washington Medical Center, Seattle
关键词
end-tidal carbon dioxide; endotracheal intubation;
D O I
10.1016/S0196-0644(05)80938-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: We compared the performed of the Fenem FEF(TM) endtidal CO2 detector with TRIMED capnometer to verify endotracheal intubation. Design: The FEF(TM) indicates the presence of CO2 by the color change of a chemically treated indicator; the TRIMED uses infrared technology. Both devices were used during 60 intubations. Setting: Intubations during in-hospital emergency situations outside of the operating room were studied. Type of participants: Adult patients undergoing intubation for respiratory failure, CPR, and other airway protection situations were enrolled in the study. Interventions: The TRIMED monitor and FEF(TM) detector were placed in series between the manual resuscitator and the patient's endotracheal tube adapter after endotracheal tube placement. Measurements and main results: We defined the acceptable criterion for detection of CO2 as production of a positive signal within six mannual resuscitator bag breaths. The TRIMED met this criterion in 58 of 60 patients (sensitivity, 0.97) and the FEF(TM) met this criterion in 59 of 60 patients (sensitivity, 0.98). A paired t test showed no statistically significant difference in performance between the two devices. In five of nine cases of intubation during CPR, the color change of the FEF(TM) was described as "subtle." In one CPR case, a positive signal was not obtained by either device. Conclusion: We conclude that the performance of the FEF(TM) CO2 detector is equal to that of the TRIMED monitor for verification of endotracheal intubation in nonCPR situations. Interpretation of FEF(TM) color changes during CPR should be approached with caution until further studies using the FEF(TM) during CPR are completed.
引用
收藏
页码:271 / 275
页数:5
相关论文
共 50 条
  • [41] CONTINUOUS END-TIDAL CO2 IN PEDIATRIC BRONCHOSCOPY
    FRANCHI, LM
    MAGGI, JC
    NUSSBAUM, E
    PEDIATRIC PULMONOLOGY, 1993, 16 (03) : 153 - 157
  • [42] End-Tidal CO2 Measurements with Noninvasive Ventilation
    Nuccio, Paul
    Hochstetler, Gary
    Jackson, Michael
    ANESTHESIA AND ANALGESIA, 2007, 105 : S111 - S111
  • [43] SPURIOUS END-TIDAL CO2 DIAGNOSED BY CAPNOGRAM
    CHEN, PP
    GIN, T
    ANAESTHESIA, 1992, 47 (10) : 910 - 911
  • [44] False-positive end-tidal CO2
    Maleck, WH
    ANNALS OF EMERGENCY MEDICINE, 1997, 30 (01) : 116 - 117
  • [45] NOVEL APPLICATION OF THE NELLCOR(R) EASY CAP(TM) END-TIDAL CO2 DETECTOR
    VENDITTI, RC
    ANESTHESIA AND ANALGESIA, 1994, 78 (05): : 1029 - 1030
  • [46] Utility of end-tidal CO2 monitoring for assessment of tracheal intubation during neonatal resuscitation at birth
    Hosono, S.
    Kitamura, T.
    Fujita, H.
    Makimoto, M.
    Minato, M.
    Okada, T.
    Takahashi, S.
    Mugishima, H.
    PROCEEDINGS OF THE 8TH WORLD CONGRESS OF PERINATAL MEDICINE, 2007, : 491 - 494
  • [47] CONTINUOUS END-TIDAL CO2 SAMPLING WITHIN THE PROXIMAL ENDOTRACHEAL-TUBE ESTIMATES ARTERIAL CO2 TENSION IN INFANTS
    RICH, GF
    SCONZO, JM
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1991, 38 (02): : 201 - 203
  • [48] End-tidal CO2 as a function of tidal volume in mechanically ventilated infants
    Greer, KJ
    Bowen, WA
    Krauss, AN
    AMERICAN JOURNAL OF PERINATOLOGY, 2003, 20 (08) : 447 - 451
  • [49] AIRWAY DEADSPACE, END-TIDAL CO2, AND CHRISTIAN BOHR
    FLETCHER, R
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1984, 28 (04) : 408 - 411
  • [50] RELATIONSHIP BETWEEN ARTERIAL AND END-TIDAL CO2 TENSIONS
    FLETCHER, R
    CRITICAL CARE MEDICINE, 1985, 13 (07) : 610 - 611