A DISPOSABLE END-TIDAL CO2 DETECTOR TO VERIFY ENDOTRACHEAL INTUBATION

被引:55
|
作者
ANTON, WR
GORDON, RW
JORDAN, TM
POSNER, KL
CHENEY, FW
机构
[1] Respiratory Care Services, University of Washington Medical Center, Seattle
[2] Department of Anesthesiology, University of Washington Medical Center, Seattle
关键词
end-tidal carbon dioxide; endotracheal intubation;
D O I
10.1016/S0196-0644(05)80938-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: We compared the performed of the Fenem FEF(TM) endtidal CO2 detector with TRIMED capnometer to verify endotracheal intubation. Design: The FEF(TM) indicates the presence of CO2 by the color change of a chemically treated indicator; the TRIMED uses infrared technology. Both devices were used during 60 intubations. Setting: Intubations during in-hospital emergency situations outside of the operating room were studied. Type of participants: Adult patients undergoing intubation for respiratory failure, CPR, and other airway protection situations were enrolled in the study. Interventions: The TRIMED monitor and FEF(TM) detector were placed in series between the manual resuscitator and the patient's endotracheal tube adapter after endotracheal tube placement. Measurements and main results: We defined the acceptable criterion for detection of CO2 as production of a positive signal within six mannual resuscitator bag breaths. The TRIMED met this criterion in 58 of 60 patients (sensitivity, 0.97) and the FEF(TM) met this criterion in 59 of 60 patients (sensitivity, 0.98). A paired t test showed no statistically significant difference in performance between the two devices. In five of nine cases of intubation during CPR, the color change of the FEF(TM) was described as "subtle." In one CPR case, a positive signal was not obtained by either device. Conclusion: We conclude that the performance of the FEF(TM) CO2 detector is equal to that of the TRIMED monitor for verification of endotracheal intubation in nonCPR situations. Interpretation of FEF(TM) color changes during CPR should be approached with caution until further studies using the FEF(TM) during CPR are completed.
引用
收藏
页码:271 / 275
页数:5
相关论文
共 50 条
  • [1] The Role of the Pediatric Disposable End-Tidal CO2 Detector in Endotracheal Intubation in Newborns. 1605
    Hany F Aziz
    John J Moore
    James B Martin
    Pediatric Research, 1998, 43 (Suppl 4) : 274 - 274
  • [2] The pediatric disposable end-tidal carbon dioxide detector role in endotracheal intubation in newborns
    Aziz H.F.
    Martin J.B.
    Moore J.J.
    Journal of Perinatology, 1999, 19 (2) : 110 - 113
  • [3] VALIDITY OF A DISPOSABLE END-TIDAL CO2 DETECTOR IN VERIFYING ENDOTRACHEAL-TUBE PLACEMENT IN INFANTS AND CHILDREN
    BHENDE, MS
    THOMPSON, AE
    COOK, DR
    SAVILLE, AL
    ANNALS OF EMERGENCY MEDICINE, 1992, 21 (02) : 142 - 145
  • [4] THE FEF END-TIDAL CO2 DETECTOR
    WEE, MYK
    ANAESTHESIA, 1990, 45 (03) : 251 - 251
  • [5] USE OF A PORTABLE END-TIDAL CO2 MONITOR TO VERIFY ENDOTRACHEAL-TUBE PLACEMENT IN NEONATES
    RAMANATHAN, R
    HEWLETT, V
    AHMAD, A
    DELEMOS, R
    CLINICAL RESEARCH, 1994, 42 (01): : A108 - A108
  • [6] END-TIDAL HALOTHANE CONCENTRATION FOR ENDOTRACHEAL INTUBATION
    YAKAITIS, RW
    BLITT, CD
    ANGIULO, JP
    ANESTHESIOLOGY, 1977, 47 (04) : 386 - 388
  • [7] END-TIDAL ENFLURANE CONCENTRATION FOR ENDOTRACHEAL INTUBATION
    YAKAITIS, RW
    BLITT, CD
    ANGIULO, JP
    ANESTHESIOLOGY, 1979, 50 (01) : 59 - 61
  • [8] BLIND NASAL INTUBATION BY MONITORING END-TIDAL CO2
    KING, HK
    WOOTEN, DJ
    ANESTHESIA AND ANALGESIA, 1989, 69 (03): : 412 - 413
  • [9] Not the end of end-tidal CO2
    Shah, Kaushal
    INTERNAL AND EMERGENCY MEDICINE, 2009, 4 (01) : 39 - 40
  • [10] Not the end of end-tidal CO2
    Kaushal Shah
    Internal and Emergency Medicine, 2009, 4 : 39 - 40