SIZE-EXCLUSION CHROMATOGRAPHY FOURIER-TRANSFORM IR SPECTROMETRY USING A SOLVENT-EVAPORATIVE INTERFACE

被引:0
|
作者
CHEUNG, PC [1 ]
BALKE, ST [1 ]
SCHUNK, TC [1 ]
机构
[1] EASTMAN KODAK CO,RES LABS,DIV ANALYT TECHNOL,ROCHESTER,NY 14650
关键词
D O I
暂无
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
A solvent-evaporative interface is used to deposit each fraction obtained from size-exclusion chromatography (SEC) as a dry polymer film on an IR transparent disc for subsequent IR analysis. Spectra without solvent interference bands result. However, in addition to removing the solvent, the interface must provide polymer films that yield undistorted spectra. Christiansen distortion is particularly troublesome because it interferes with quantitative interpretation In the affected spectrum. Undistorted spectra were invariably obtained from continuous films and sometimes obtained from discontinuous films (separate particles). Carbon-coated KCl discs and either bare or carbon-coated germanium discs provided morphologies with good spectra. Polymer deposition on bare KCI discs often provided unacceptable morphologies. Surface-wetting properties of the substrate appear to dominate deposit morphology.
引用
收藏
页码:265 / 279
页数:15
相关论文
共 50 条
  • [21] Purification of bacteriocins using size-exclusion chromatography
    Rather, Irfan A.
    Hamad, Alshammari Fanar
    Bajpai, Vivek K.
    BANGLADESH JOURNAL OF PHARMACOLOGY, 2016, 11 (02) : 281 - 284
  • [22] MICROCOLUMN LIQUID-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED SPECTROMETRY INTERFACE USING A POTASSIUM-BROMIDE DISK
    FUJIMOTO, C
    MORITA, T
    JINNO, K
    OCHIAI, S
    CHROMATOGRAPHIA, 1987, 23 (07) : 512 - 516
  • [23] USE OF A GEL-PERMEATION CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED SPECTROMETRY INTERFACE FOR POLYMER ANALYSIS
    WILLIS, JN
    WHEELER, L
    CHROMATOGRAPHIC CHARACTERIZATION OF POLYMERS: HYPHENATED AND MULTIDIMENSIONAL TECHNIQUES, 1995, 247 : 253 - 263
  • [24] Size-exclusion chromatography performed in capillaries -: Studies by liquid chromatography mass spectrometry
    Smoluch, MT
    Mak, P
    Chervet, JP
    Höhne, G
    Silberring, J
    JOURNAL OF CHROMATOGRAPHY B, 1999, 726 (1-2): : 37 - 43
  • [25] Probing Protein Denaturation during Size-Exclusion Chromatography Using Native Mass Spectrometry
    Ventouri, Iro K.
    Malheiro, Daniel B. A.
    Voeten, Robert L. C.
    Kok, Sander
    Honing, Maarten
    Somsen, Govert W.
    Haselberg, Rob
    ANALYTICAL CHEMISTRY, 2020, 92 (06) : 4292 - 4300
  • [26] ONLINE SUPERCRITICAL FLUID CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED SPECTROMETRY
    SHAFER, KH
    GRIFFITHS, PR
    ANALYTICAL CHEMISTRY, 1983, 55 (12) : 1939 - 1942
  • [27] SUPERCRITICAL FLUID CHROMATOGRAPHY FOURIER-TRANSFORM MASS-SPECTROMETRY
    LEE, ED
    HENION, JD
    CODY, RB
    KINSINGER, JA
    ANALYTICAL CHEMISTRY, 1987, 59 (09) : 1309 - 1312
  • [28] Principles and potential of solvent gradient size-exclusion chromatography for polymer analysis
    Niezen, Leon E.
    Kruijswijk, Jordy D.
    van Henten, Gerben B.
    Pirok, Bob W. J.
    Staal, Bastiaan B. P.
    Radke, Wolfgang
    Philipsen, Harry J. A.
    Somsen, Govert W.
    Schoenmakers, Peter J.
    ANALYTICA CHIMICA ACTA, 2023, 1253
  • [29] Size-exclusion chromatography of protected synthetic polypeptide tandems in an organic solvent
    Karnoup, AS
    Shiryaev, VM
    Medvedkin, VN
    Mitin, YV
    JOURNAL OF PEPTIDE RESEARCH, 1997, 49 (03): : 232 - 239
  • [30] COUPLED GAS-CHROMATOGRAPHY AND FOURIER-TRANSFORM INFRARED SPECTROMETRY
    GRIFFITHS, PR
    HENRY, DE
    PROGRESS IN ANALYTICAL SPECTROSCOPY, 1986, 9 (04): : 455 - 482