TIME-RESOLVED EMISSION FROM LASER-ABLATED URANIUM

被引:25
|
作者
STOFFELS, E [1 ]
VANDEWEIJER, P [1 ]
VANDERMULLEN, J [1 ]
机构
[1] PHILIPS RES LABS,5600 JA EINDHOVEN,NETHERLANDS
关键词
D O I
10.1016/0584-8547(91)80198-C
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Time-resolved emission spectra from the plasma, induced by laser ablation of uranium samples have been studied. The dependence of the emission intensity on time is strongly affected by the nature and pressure of the buffer gas. Air and argon have been used in the pressure range 0.002 to 5 mbar. The emission intensity as a function of time displays three maxima. indicating that three different processes within the expanding plasma plume are involved. On basis of the time-resolved spectra we propose a model that explains qualitatively the phenomena that are responsible for this time behaviour.
引用
收藏
页码:1459 / 1470
页数:12
相关论文
共 50 条
  • [41] Time-resolved emission: Distortion-free measurements of analog circuits by time-resolved emission
    Sarault, Keith R.
    Boon, Gerben
    Electronic Device Failure Analysis, 2009, 11 (02): : 6 - 14
  • [42] Biofunctionalization of laser-ablated gold nanoparticles
    Riabinina, Daria
    Zhang, JianMing
    Chaker, Mohamed
    Ma, Dongling
    Tijssen, Peter
    NANOTECH CONFERENCE & EXPO 2009, VOL 1, TECHNICAL PROCEEDINGS: NANOTECHNOLOGY 2009: FABRICATION, PARTICLES, CHARACTERIZATION, MEMS, ELECTRONICS AND PHOTONICS, 2009, : 205 - +
  • [43] TIME-RESOLVED CHARACTERISTICS OF SECOND HARMONIC EMISSION FROM THE LASER-PRODUCED PLASMAS
    徐至展
    张伟清
    赵世诚
    周复正
    A Monthly Journal of Science, 1983, (09) : 1290 - 1290
  • [44] TIME-RESOLVED SPECTROSCOPY OF LASER-EMISSION FROM DYE-DOPED DROPLETS
    BISWAS, A
    LATIFI, H
    ARMSTRONG, RL
    PINNICK, RG
    OPTICS LETTERS, 1989, 14 (04) : 214 - 216
  • [45] Recolonization of laser-ablated bacterial biofilm
    Nandakumar, K
    Obika, H
    Utsumi, A
    Toshihiko, O
    Yano, T
    BIOTECHNOLOGY AND BIOENGINEERING, 2004, 85 (02) : 185 - 189
  • [46] Time-resolved investigation of the transient surface reflection changes of subpicosecond excimer laser ablated liquids
    Hopp, B
    Tóth, Z
    Gál, K
    Mechler, A
    Bor, Z
    Moustaizis, SD
    Georgiou, S
    Fotakis, C
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1999, 69 : S191 - S194
  • [47] Doppler diagnostics of laser-ablated biotisues
    Dmitrev, AK
    Kortunov, VN
    Ul'yanov, VA
    11TH INTERNATIONAL SCHOOL ON QUANTUM ELECTRONICS: LASER PHYSICS AND APPLICATIONS, 2001, 4397 : 425 - 430
  • [48] Time-Resolved Shadowgraphic Imaging of Femtosecond Laser Ablated Micro-Holes in Silica Glass
    Wei J.
    Zhang B.
    Liu H.
    Zhang H.
    Zhongguo Jiguang/Chinese Journal of Lasers, 2019, 46 (05):
  • [49] Matrix isolation FTIR investigation of laser-ablated uranium oxide in argon and nitrogen matrices
    Materials Chemistry Division, Indira Gandhi Ctr. for Atom. Res., Kalpakkam 603 102, India
    Bull Mater Sci, 4 (785-790):
  • [50] A matrix isolation FTIR investigation of laser-ablated uranium oxide in argon and nitrogen matrices
    K Sankaran
    K Sundararajan
    K S Viswanathan
    Bulletin of Materials Science, 1999, 22 : 785 - 790