Vertical pullout capacity of horizontal anchor plates in the presence of seismic and seepage forces

被引:10
|
作者
Bhattacharya, Paramita [1 ]
Kumar, Jyant [2 ]
机构
[1] Birla Inst Technol & Sci Pilani, Dept Civil Engn, Hyderabad, Andhra Pradesh, India
[2] Indian Inst Sci, Dept Civil Engn, Bangalore, Karnataka, India
关键词
anchors; earthquakes; failure; limit analysis; sand; seepage;
D O I
10.1080/17486025.2014.902116
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
In the presence of pseudo-static horizontal earthquake body forces and horizontal seepage forces, the vertical pullout capacity of horizontal plate anchors buried in sand has been determined by using the lower bound theorem of the limit analysis in combination with finite elements and linear optimisation. The variations of the pullout factor (a) F-gamma with (a(h) + i y(w)/y(sub)) and (b) the factor F-q with alpha(h), have been established for different embedment ratio of the anchor plate and the friction angle of sand. It is noted that the pullout capacity decreases continuously with increases in the values of ah and (i y(w)/y(sub)). The pullout capacity becomes continuously higher for greater values of the embedment ratio and interface friction angle. The failure patterns have been found to become unsymmetrical in the presence of horizontal body forces.
引用
收藏
页码:294 / 302
页数:9
相关论文
共 44 条
  • [31] Mechanism of bearing capacity of vertical anchor plates in sand considering interface friction based on DEM method
    Wang, Hao
    Sun, Yu-Hai
    Jiang, Jian-Hong
    Liu, Ming-Peng
    Zhang, Hong-Bo
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2021, 43 : 117 - 120
  • [32] Variational analysis of the ultimate pullout capacity of shallow circular anchor plates in rock foundations based on the Hoek-Brown failure criterion
    Zhao, Lian-Heng
    Yang, Xin-Ping
    Huang, Fu
    Tang, Yi-Gao
    Hu, Shi-Hong
    INTERNATIONAL JOURNAL OF ROCK MECHANICS AND MINING SCIENCES, 2018, 106 : 190 - 197
  • [33] Experimental Study on Uplift Capacity of Horizontal Circular and Strip Anchor Plates in Two-Layered Cohesionless Soil
    Bhattacharya, Paramita
    GEOTECHNICAL APPLICATIONS, VOL 4, 2019, 13 : 79 - 87
  • [34] Seismic vertical uplift capacity of horizontal strip anchors using pseudo-dynamic approach
    Ghosh, Priyanka
    COMPUTERS AND GEOTECHNICS, 2009, 36 (1-2) : 342 - 351
  • [35] Vertical Uplift Capacity of Rectangular and Square Plate Anchors in Granular Soil under Seismic Forces
    Ganesh, R.
    Sahoo, Jagdish Prasad
    JOURNAL OF EARTHQUAKE ENGINEERING, 2022, 26 (14) : 7366 - 7383
  • [36] Seismic uplift capacity of shallow horizontal strip anchor under oblique load using pseudo-dynamic approach
    Rangari, Sunil M.
    Choudhury, Deepankar
    Dewaikar, D. M.
    SOILS AND FOUNDATIONS, 2013, 53 (05) : 692 - 707
  • [37] Vertical bearing capacity of a pile-liquefiable sandy soil foundation under horizontal seismic force
    Huang Zhanfang
    Bai Xiaohong
    Yin Chao
    Wang Yanping
    PLOS ONE, 2020, 15 (03):
  • [38] Performance of the Condensation Process for Water Vapour in the Presence of a Non-Condensable Gas on Vertical Plates and Horizontal Tubes
    Poredos, Primoz
    Petelin, Nada
    Zel, Tilen
    Vidrih, Boris
    Gataric, Pero
    Kitanovski, Andrej
    ENERGIES, 2021, 14 (08)
  • [39] Variation analysis of ultimate pullout capacity of shallow horizontal strip anchor plate with 2-layer overlying soil based on nonlinear M-C failure criterion
    Zhao Lian-heng
    Tan Yi-gao
    Nie Zhi-hong
    Yang Xin-ping
    Hu Shi-hong
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2018, 25 (11) : 2802 - 2818
  • [40] Seismic Capacity Test of Overhead Crane Under Horizontal and Vertical Excitation - Element Model Test Results on Nonlinear Response Behavior -
    Suzuki, Kenichi
    Inagaki, Masakatsu
    Iijima, Tadashi
    JOURNAL OF DISASTER RESEARCH, 2010, 5 (04) : 369 - 377