A MODULAR 4-PI COUNTER FOR BETA-DELAYED NEUTRONS

被引:4
|
作者
KUNZE, V [1 ]
SCHMIDTOTT, WD [1 ]
BOSCHWICKE, U [1 ]
BOTTGER, R [1 ]
KLEIN, H [1 ]
机构
[1] PHYS TECH BUNDESANSTALT,D-38116 BRAUNSCHWEIG,GERMANY
关键词
D O I
10.1016/0168-9002(95)00125-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on the construction of a detector array for low-energy beta-delayed neutrons consisting of sixteen NE 213 scintillation counters. Three pulse-shape discrimination techniques were compared, with special emphasis on the discrimination of neutrons from gamma-rays in the energy region down to 50 keVee (keV electron equivalent). The efficiency as a function of neutron energy was obtained by comparing the precisely known neutron spectrum from the spontaneous fission of Cf-252 and the neutron distribution measured in coincidence with the fission events. The neutron energy was determined with the time-of-flight (TOF) technique. In order to examine the light output function L(E(p)) for recoil protons, a careful energy calibration was done by fitting the Compton edges from standard gamma-ray sources. Neutron efficiencies were also calculated with a Monte Carlo code. Agreement between measured and calculated efficiency curves was observed for two differently shaped detectors and neutron flight paths of 1 and 3 m. This correspondence justifies the efficiency calculation for the 4 pi array with the source in the center. For neutron energies above 800 keV an error of less than 5% in detection efficiency can be reached.
引用
收藏
页码:263 / 269
页数:7
相关论文
共 50 条
  • [21] PREPARATION OF THIN 4-PI BETA-SOURCES FOR ABSOLUTE MEASUREMENTS
    DU, HS
    JIA, Z
    YU, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 251 (02): : 254 - 257
  • [22] MSU 4-PI ARRAY
    WESTFALL, GD
    YURKON, J
    MORRIS, L
    MAIER, M
    VANDERMOLEN, A
    VANDERPLICHT, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 57 - NUCL
  • [23] CONTROL OF INTERNAL CONTAMINATION USING A 4-PI GEOMETRIC WHOLE-BODY-COUNTER
    DELWAIDE, PA
    JOURNAL BELGE DE RADIOLOGIE, 1970, 53 (05): : 405 - &
  • [24] Prediction for an island of beta-delayed neutron precursors
    Zhang, Li
    Chinese journal of nuclear physics, 1993, 15 (02): : 164 - 166
  • [25] Colloquium: Beta-delayed fission of atomic nuclei
    Andreyev, Andrei N.
    Huyse, Mark
    Van Duppen, Piet
    REVIEWS OF MODERN PHYSICS, 2013, 85 (04) : 1541 - 1559
  • [26] Beta-delayed two-particle emission
    Borge, MJG
    PROTON-EMITTING NUCLEI, PROCON '99, 2000, 518 : 264 - 274
  • [27] Opportunities for the study of beta-delayed fission at ISOLDE
    Köster, U
    SEMINAR ON FISSION, 2000, : 167 - 173
  • [28] BETA-DELAYED NEUTRON DECAY OF BE-14
    BELBOT, MD
    KOLATA, JJ
    LAMKIN, K
    TIGHE, RJ
    ZAHAR, M
    HARKEWICZ, R
    MORRISSEY, DJ
    ORR, NA
    RONNINGEN, RM
    SHERRILL, BM
    WINGER, JA
    CARPENTER, M
    PHYSICAL REVIEW C, 1995, 51 (05) : 2372 - 2380
  • [29] THE BETA-DELAYED MULTI-NEUTRON EMISSION
    LYUTOSTANSKY, YS
    SIROTKIN, VK
    PANOV, IV
    PHYSICS LETTERS B, 1985, 161 (1-3) : 9 - 12
  • [30] A 4-PI DILEPTON SPECTROMETER - PEPSI
    BUDA, A
    BACELAR, JCS
    BALANDA, A
    VANKLINKEN, J
    SUJKOWSKI, Z
    VANDERWOUDE, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 335 (03): : 479 - 486