ON THE CONVERSION COEFFICIENTS FROM FLUENCE TO AMBIENT DOSE-EQUIVALENT

被引:0
|
作者
FERRARI, A
PELLICCIONI, M
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The conversion coefficients from photon fluence (or other physical quantities) to ambient dose equivalent recommended in ICRU Report 47 are overestimated in the energy range 4-10 MeV, since they are derived from calculations carried out with the ICRU sphere in air. Such a procedure is clearly in contraction with the definition of the ambient dose equivalent given by ICRU itself. The values of the conversion coefficients consistently evaluated by Monte Carlo calculations using the FLUKA code, are presented. The resulting ambient dose equivalent is shown not to be conservative with respect to the effective dose equivalent when the photon energy exceeds about 3 MeV.
引用
收藏
页码:251 / 255
页数:5
相关论文
共 50 条
  • [21] NEUTRON FLUENCE-TO-DOSE EQUIVALENT CONVERSION FACTORS
    KLUGE, H
    ALBERTS, WG
    HEALTH PHYSICS, 1981, 40 (03): : 414 - 415
  • [22] Calculation of fluence to dose conversion coefficients in partial exposure
    Iwai, S
    Kitaichi, M
    Katagiri, M
    Sawamura, T
    Sawamura, S
    APPLIED RADIATION AND ISOTOPES, 2005, 63 (5-6) : 639 - 644
  • [23] Fluence-to-effective dose conversion coefficients for muons
    Ferrari, A
    Pelliccioni, M
    Pillon, M
    RADIATION PROTECTION DOSIMETRY, 1997, 74 (04) : 227 - 233
  • [24] USE OF THE EFFECTIVE DOSE-EQUIVALENT
    SHIELDS, RA
    LAWSON, RS
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (01) : 186 - 187
  • [25] DOSE-EQUIVALENT RATE FROM COSMIC RAY NEUTRONS
    WATT, DE
    HEALTH PHYSICS, 1967, 13 (05): : 501 - +
  • [27] Spectrally average conversion coefficients for air kerma to ambient dose equivalent for clinical linear accelerator
    Frota, Marco A.
    Crispim, Verginia R.
    Silva, Ademir X.
    Kelecom, Alphonse
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (01) : 174 - 177
  • [28] EFFECTIVE DOSE-EQUIVALENT MEASUREMENTS IN CARDIOLOGY
    RAWLINGS, DJ
    FAULKNER, K
    HARRISON, RM
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (728): : 772 - 772
  • [29] Personal dose equivalent conversion coefficients for neutron fluence over the energy range of 20-250 MeV
    Olsher, R. H.
    McLean, T. D.
    Justus, A. L.
    Devine, R. T.
    Gadd, M. S.
    RADIATION PROTECTION DOSIMETRY, 2010, 138 (03) : 199 - 204
  • [30] Ambient Dose Equivalent, Effective Dose and Mean Sv/Gy Conversion Coefficients from Scattered X-Ray Spectra in Mammography
    Kunzel, R.
    Herdade, S. B.
    Costa, P. R.
    Terini, R. A.
    Levenhagen, R. S.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2092 - +