PARTICLE COLLECTION EFFICIENCY OF 2 PERSONAL RESPIRABLE DUST SAMPLERS

被引:0
|
作者
TSAI, CJ [1 ]
SHIH, TS [1 ]
机构
[1] COUNCIL LABOR AFFAIRS,INST OCCUPAT SAFETY & HLTH,TAIPEI,TAIWAN
来源
关键词
D O I
10.1202/0002-8894(1995)056<0911:PCEOTP>2.0.CO;2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study determines acceptable flow rates for both SKC and 10-mm nylon cyclone samplers to match the sampling efficiency curve specified by the new American Conference of Governmental Industrial Hygienists (ACGIH) criteria for respirable dust sampling. Monodisperse test particles were used to evaluate the relationship of particle collection efficiency versus particle aerodynamic diameter by fluorometric technique. Original pow rate at 1.7 L/min for the 10-mm nylon cyclone sampler has been confirmed to match the ACGIH (1984) criteria for solid particles. The original flow rate at 1.9 L/min for the SKC cyclone sampler has been found to result in a solid particle collection efficiency curve slightly lower than the British Medical Research Council criteria. When sampling solid particles, the new ACGIH criteria was matched at the pow rates of 1.3 and 2.2 L/min for 10-mm nylon and SKC cyclone samplers, respectively. While the 2.2 L/min pow rate for the SKC sampler is consistent with most previous studies, the 1.3 L/min flow rate for the 10-mm nylon cyclone is quite different. Furthermore, experimental results indicate that the collection efficiency of the 10-mm nylon cyclone sampler is lower for liquid particles than solid particles when particles are larger than the cut point. The difference in collection efficiency due to particle material has been found to be insignificant for the SKC sampler. Pump pulsation and the orientation of a sampler also influenced particle collection efficiency.
引用
收藏
页码:911 / 918
页数:8
相关论文
共 50 条
  • [21] EFFECT OF ALTITUDE ON PERSONAL RESPIRABLE DUST SAMPLER CALIBRATION
    TREAFTIS, HN
    TOMB, TF
    CARDEN, HF
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1976, 37 (03): : 133 - 138
  • [22] EFFECT OF ALTITUDE ON PERSONAL RESPIRABLE DUST SAMPLER CALIBRATION
    LEIDEL, NA
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1977, 38 (05): : 229 - 230
  • [23] THE APPLICATION OF PERFORMANCE STANDARDS TO PERSONAL AIRBORNE DUST SAMPLERS
    KENNY, LC
    LIDEN, G
    ANNALS OF OCCUPATIONAL HYGIENE, 1989, 33 (03): : 289 - 300
  • [24] COLLECTION EFFICIENCY OF LIQUID SAMPLERS FOR MICROBIOLOGICAL AEROSOLS
    HENNINGSON, EW
    FANGMARK, I
    LARSSON, E
    WIKSTROM, LE
    JOURNAL OF AEROSOL SCIENCE, 1988, 19 (07) : 911 - 914
  • [25] Collection efficiency and design of microbial air samplers
    Whyte, W.
    Green, G.
    Albisu, A.
    Journal of Aerosol Science, 2007, 38 (01): : 97 - 110
  • [26] Collection efficiency and design of microbial air samplers
    Whyte, W.
    Green, G.
    Albisu, A.
    JOURNAL OF AEROSOL SCIENCE, 2007, 38 (01) : 97 - 110
  • [27] Monolithic carbonaceous denuders as an enhancement of portable personal GGP samplers for the collection of airborne vapour/particle mixtures
    Kohlmeier, V.
    Dragan, G. C.
    Orasche, J.
    Schnelle-Kreis, J.
    Breuer, D.
    Zimmermann, R.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2019, 79 (03): : 47 - 54
  • [28] COLLECTION OF LARGE QUANTITIES OF RESPIRABLE COTTON DUST FOR BYSSINOSIS RESEARCH
    BROWN, DF
    BERNI, RJ
    TEXTILE RESEARCH JOURNAL, 1977, 47 (02) : 152 - 154
  • [29] The Influence of Air Flow Velocity and Particle Size on the Collection Efficiency of Passive Electrostatic Aerosol Samplers
    Imani, Ramin Jajarmi
    Ladhani, Laila
    Pardon, Gaspar
    van der Wijngaart, Wouter
    Robert, Etienne
    AEROSOL AND AIR QUALITY RESEARCH, 2019, 19 (02) : 195 - 203
  • [30] SUPPRESSION AND COLLECTION OF RESPIRABLE COAL DUST USING WATER AND STEAM
    TOMB, TF
    CHENG, L
    STEIN, RL
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1972, 200 (DEC29) : 724 - 736