ANALYSIS OF CHIRAL CARBOXYLIC-ACIDS IN WINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COUPLED UV AND CIRCULAR-DICHROISM DETECTION

被引:14
|
作者
ZERBINATI, O
AIGOTTI, R
DANIELE, PG
机构
[1] Dipartimento di Chimica Analitica, Università di Torino, I-10125 Turin
关键词
D O I
10.1016/0021-9673(94)80251-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A circular dichroism (CD) spectrophotometer, equipped with a flow cell, and a UV detector were connected in series and were used for coupled UV-CD detection of optically active carboxylic acids. The limits of detection and the linear range for the enantiomers of tartaric, malic, lactic and ascorbic acids are reported. Several wines were analysed and CD detection proved to be sensitive enough for accurate determinations. The combined UV-CD detection was helpful for identifying the peaks and allowed the calculation of enantiomeric ratios.
引用
收藏
页码:281 / 285
页数:5
相关论文
共 50 条
  • [1] CHIRAL DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY BY VIBRATIONAL CIRCULAR-DICHROISM
    TRAN, CD
    GRISHKO, VI
    HUANG, GL
    ANALYTICAL CHEMISTRY, 1994, 66 (17) : 2630 - 2635
  • [2] ANALYSIS OF AMINO-ACIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CIRCULAR-DICHROISM DETECTION
    TAKATORI, K
    TOYAMA, S
    FUJII, S
    KAJIWARA, M
    CHEMICAL & PHARMACEUTICAL BULLETIN, 1995, 43 (10) : 1797 - 1799
  • [3] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF CARBOXYLIC-ACIDS
    SCHWARZENBACH, R
    JOURNAL OF CHROMATOGRAPHY, 1982, 251 (03): : 339 - 358
  • [4] ANALYSIS OF PROTEINS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CIRCULAR-DICHROISM SPECTROPHOTOMETRIC DETECTION
    KUROSU, Y
    SASAKI, T
    TAKAKUWA, T
    SAKAYANAGI, N
    HIBI, K
    SENDA, M
    JOURNAL OF CHROMATOGRAPHY, 1990, 515 : 407 - 414
  • [5] FLUORESCENCE DETECTED CIRCULAR-DICHROISM AS A DETECTION PRINCIPLE IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SYNOVEC, RE
    YEUNG, ES
    JOURNAL OF CHROMATOGRAPHY, 1986, 368 (01): : 85 - 93
  • [6] CIRCULAR-DICHROISM DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - EVALUATION OF THE ANISOTROPY FACTOR
    BERTUCCI, C
    DOMENICI, E
    SALVADORI, P
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (8-12) : 843 - 846
  • [7] USE OF CIRCULAR-DICHROISM AS A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY DETECTOR
    WESTWOOD, SA
    GAMES, DE
    SHEEN, L
    JOURNAL OF CHROMATOGRAPHY, 1981, 204 (JAN): : 103 - 107
  • [8] CHIRAL STATIONARY PHASES AND CIRCULAR-DICHROISM DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - DETERMINATION OF STEREOCHEMICAL PURITY OF DRUGS
    BERTUCCI, C
    ROSINI, C
    PINI, D
    SALVADORI, P
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1987, 5 (02) : 171 - 176
  • [9] THERMAL LENS CIRCULAR-DICHROISM DETECTOR FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    XU, MR
    TRAN, CD
    ANALYTICAL CHEMISTRY, 1990, 62 (22) : 2467 - 2471
  • [10] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF ESTERS OF ALIPHATIC AND AROMATIC CARBOXYLIC-ACIDS
    KRIZ, J
    VODICKA, L
    BURDA, J
    ADAMCOVA, E
    JOURNAL OF CHROMATOGRAPHY, 1987, 386 : 159 - 172