LASER MICROPROBE AND RESONANCE IONIZATION MASS-SPECTROMETRY FOR THE ANALYSIS OF TRACE-ELEMENTS IN SOLIDS

被引:6
|
作者
HUNG, TY
SU, CS
机构
[1] Institute of Nuclear Science, National Tsing Hua University, Hsinchu
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1992年 / 63卷 / 11期
关键词
D O I
10.1063/1.1143443
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A laser microprobe and resonance ionization mass spectrometer (LAM/RIMS) has been designed and constructed by combining a newly designed simple laser microprobe (LAM) with a continuous-wave (cw) resonance ionization mass spectrometer, for the direct analysis of trace elements in solids. The LAM/RIMS has achieved a simultaneous record of the complete mass spectrum of a solid sample, and a three orders of magnitude enhancement in the detection signal of the selected trace elements in the solid, with precise spatial information, and without the need of sample preparation. A n-type silicon wafer containing an impurity of sodium in parts per billion order has been easily detected by applying a single shot of an ablation laser pulse and a cw resonance ionization laser. The result has also shown that the sensitivity of the LAM/RIMS for the analysis of selected trace elements is better than the Auger electron spectroscopy and is comparable to neutron activation analysis.
引用
收藏
页码:5299 / 5305
页数:7
相关论文
共 50 条
  • [21] QUANTITATIVE-ANALYSIS OF TRACE-ELEMENTS IN CARBONATES USING LASER ABLATION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    PERKINS, WT
    FUGE, R
    PEARCE, NJG
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (06) : 445 - 449
  • [22] LASER RESONANCE IONIZATION MASS-SPECTROMETRY FOR KR-81 ANALYSIS
    LEHMANN, BE
    LOOSLI, HH
    OESCHGER, H
    RAUBER, D
    HURST, GS
    ALLMAN, SL
    CHEN, CH
    KRAMER, SD
    THONNARD, N
    WILLIS, RD
    RADIOCARBON, 1986, 28 (2A) : 223 - 228
  • [23] ORGANIC AND SPECIATION ANALYSIS BY LASER MICROPROBE MASS-SPECTROMETRY
    GIJBELS, R
    VANVAECK, L
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 334 (07): : 683 - 684
  • [24] TRACE-ELEMENTS IN COAL DUST BY SPARK-SOURCE MASS-SPECTROMETRY
    SHARKEY, AG
    KESSLER, T
    FRIEDEL, RA
    ADVANCES IN CHEMISTRY SERIES, 1975, (141): : 48 - 56
  • [25] DETECTION OF TRACE AMOUNTS OF ACTINIDES BY RESONANCE IONIZATION MASS-SPECTROMETRY
    RIMKE, H
    HERRMANN, G
    MUHLECK, C
    SATTELBERGER, P
    TRAUTMANN, N
    AMES, F
    KLUGE, HJ
    OTTEN, EW
    REHKLAU, D
    RUSTER, W
    INORGANICA CHIMICA ACTA, 1987, 140 (1-2) : 277 - 278
  • [26] TRACE DETECTION OF RADIOTOXIC ISOTOPES BY RESONANCE IONIZATION MASS-SPECTROMETRY
    WENDT, K
    PASSLER, G
    TRAUTMANN, N
    PHYSICA SCRIPTA, 1995, T58 : 104 - 108
  • [27] PULSED LASER DESORPTION FOR RESONANCE IONIZATION MASS-SPECTROMETRY
    NOGAR, NS
    ESTLER, RC
    MILLER, CM
    ANALYTICAL CHEMISTRY, 1985, 57 (13) : 2441 - 2444
  • [28] INFLUENCE OF LASER CHARACTERISTICS ON RESONANCE IONIZATION MASS-SPECTROMETRY
    YOUNG, JP
    SHAW, RW
    GOERINGER, DE
    SMITH, DH
    RESONANCE IONIZATION SPECTROSCOPY 1988, 1989, 94 : 367 - 370
  • [29] RESONANCE IONIZATION MASS-SPECTROMETRY
    YOUNG, JP
    SHAW, RW
    SMITH, DH
    ANALYTICAL CHEMISTRY, 1989, 61 (22) : A1271 - A1279
  • [30] SPECTRAL STUDIES OF ACTINIDE ELEMENTS BY RESONANCE IONIZATION MASS-SPECTROMETRY
    DONOHUE, DL
    YOUNG, JP
    SMITH, DH
    APPLIED SPECTROSCOPY, 1985, 39 (01) : 93 - 97