TREATMENT DELIVERY ACCURACY IN INTENSITY-MODULATED CONFORMAL RADIOTHERAPY

被引:21
|
作者
CONVERY, DJ [1 ]
ROSENBLOOM, ME [1 ]
机构
[1] ROYAL MARSDEN NHS TRUST,INST CANC RES,JOINT DEPT PHYS,SUTTON SM2 5PT,SURREY,ENGLAND
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1995年 / 40卷 / 06期
关键词
D O I
10.1088/0031-9155/40/6/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The importance of geometric and dosimetric inaccuracies in the delivery of conformal radiotherapy using intensity-modulated x-ray fields is assessed. It is shown that although the incident intensity or fluence profiles may have large gradients, the resulting absorbed dose profile gradients are shallower because of electron transport and photon scatter. This makes the interleaving of dose contributions from the many intensity-modulated fields used less critically dependent on their relative positions and on the accuracy of profile generation. It is found that the expected geometric and dosimetric inaccuracies do not make this technique impracticable provided that good patient fixation and beam delivery can be assured.
引用
收藏
页码:979 / 999
页数:21
相关论文
共 50 条
  • [31] Outcomes and prognostic factors of conformal radiotherapy versus intensity-modulated radiotherapy for nasopharyngeal carcinoma
    Wei Lu Kuang
    Qin Zhou
    Liang Fang Shen
    Clinical and Translational Oncology, 2012, 14 : 783 - 790
  • [32] Outcomes and prognostic factors of conformal radiotherapy versus intensity-modulated radiotherapy for nasopharyngeal carcinoma
    Kuang, Wei Lu
    Zhou, Qin
    Shen, Liang Fang
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2012, 14 (10): : 783 - 790
  • [33] Intensity-modulated radiotherapy of sacral chordoma - A case report and a comparison with stereotactic conformal radiotherapy
    Thilmann, C
    Schulz-Ertner, D
    Zabel, A
    Herfarth, KK
    Wannenmacher, M
    Debus, J
    ACTA ONCOLOGICA, 2002, 41 (04) : 395 - 399
  • [34] Comparison of conformal radiotherapy, intensity-modulated radiotherapy and tomotherapy irradiation techniques in prostate cancers
    Tugrul, Taylan
    Olacak, Nezahat
    Koylu, Murat
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (03) : 276 - 279
  • [35] Comparison of intensity-modulated radiotherapy with conventional conformal radiotherapy for complex-shaped tumors
    Pirzkall, A
    Carol, M
    Lohr, F
    Höss, A
    Wannenmacher, M
    Debus, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (05): : 1371 - 1380
  • [36] 3D conformal radiotherapy and intensity-modulated radiotherapy: towards dose optimization
    Almudena Zapatero Laborda
    Revista de Oncología, 2002, 4 (2): : 103 - 108
  • [37] A Multicentre Timing Study of Intensity-modulated Radiotherapy Planning and Delivery
    Thomas, S. J.
    Vinall, A.
    Poynter, A.
    Routsis, D.
    CLINICAL ONCOLOGY, 2010, 22 (08) : 658 - 665
  • [38] DOSIMETRIC COMPARISON OF VOLUMETRIC INTENSITY-MODULATED ARC (RAPIDARC) THERAPY, INTENSITY-MODULATED RADIOTHERAPY, AND 3D CONFORMAL RADIOTHERAPY FOR PRIMARY LIVER TUMOURS
    John, Jacob
    Sivasevan, Roshni
    Sudha, Arun Sankar
    Sivanandan, Choondal Devan
    Abdurahman, Sajeed
    Paramu, Raghukumar
    Sreedevi, Shaiju Vasudevan
    George, Preethi Sara
    Jayaprakash, Puthuveettil Govindan
    EUROPEAN JOURNAL OF CANCER, 2015, 51 : E34 - E34
  • [39] Intensity-modulated radiotherapy for neoadjuvant treatment of gastric cancer
    Knab, Brian
    Rash, Carla
    Farrey, Karl
    Jani, Ashesh B.
    MEDICAL DOSIMETRY, 2006, 31 (04) : 292 - 297
  • [40] The role of intensity-modulated radiotherapy in the treatment of parotid tumors
    Bragg, CM
    Conway, J
    Robinson, MH
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (03): : 729 - 738