SENSOR SYSTEM FOR MEASUREMENT OF 2-D DISPLACEMENT AND FORCE VECTORS

被引:1
|
作者
JANOCHA, H [1 ]
机构
[1] UNIV HANNOVER,INST PROD ENGN,DIV MACHINE & CONTROL,W-3000 HANNOVER,GERMANY
关键词
DISPLACEMENT SENSOR; FORCE SENSOR; STRAIN-GAUGE SENSOR; ERROR COMPENSATION;
D O I
10.1016/0924-4247(92)80153-T
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Modern sensors should provide output signals that are compatible with microelectronic systems, they should require minimal circuit complexity when used in microprocessors systems and should be exchangeable as an anonymous unit. The sensor discussed in this paper complies with all of these requirements. It is based on proven strain-gauge technology and can measure both orthogonal components of a two-dimensional (2-D) displacement or force vector with high accuracy. Integrated electronics eliminate both systematic errors and manufacturing tolerances.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 50 条
  • [31] A planar capacitive sensor for 2D long-range displacement measurement
    Yu, Jian-ping
    Wang, Wen
    Lu, Ke-qing
    Mei, De-qing
    Chen, Zi-chen
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE C-COMPUTERS & ELECTRONICS, 2013, 14 (04): : 252 - 257
  • [32] A planar capacitive sensor for 2D long-range displacement measurement
    Jian-ping Yu
    Wen Wang
    Ke-qing Lu
    De-qing Mei
    Zi-chen Chen
    Journal of Zhejiang University SCIENCE C, 2013, 14 : 252 - 257
  • [33] Measurement and evaluation of hole burr based on 2D laser displacement sensor
    Liang J.
    Zhang K.
    Qiu Y.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2022, 54 (01): : 156 - 162
  • [34] A Measurement System to Realize 3-D Carotid Occlusion Measurement From 2-D Conventional Ultrasonography
    Capriglione, Domenico
    Ferrigno, Luigi
    Miele, Gianfranco
    Paciello, Vincenzo
    Paolillo, Alfredo
    Sommella, Paolo
    IEEE SENSORS JOURNAL, 2014, 14 (03) : 747 - 757
  • [35] 2-D finite-element modeling of electrostatic sensor for tomography system
    Thuku, Iliya Tizhe
    Rahmat, Mohd Fua'ad
    Wahab, Norhaliza Abdul
    Tajdari, Teimour
    Yusuf, Abdulrahamam Amuda
    SENSOR REVIEW, 2013, 33 (02) : 104 - 113
  • [36] 3D force and displacement sensor for SFA and AFM measurements
    Kristiansen, Kai
    McGuiggan, Patricia
    Carver, Greg
    Meinhart, Carl
    Israelachvili, Jacob
    LANGMUIR, 2008, 24 (04) : 1541 - 1549
  • [37] A Novel Self-Correction Method for Linear Displacement Measurement Based on 2-D Synthesis Mechanism
    Yu, Hai
    Wan, Qiuhua
    Zhao, Changhai
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [38] Measurement method of tooth friction force for helical gears by laser displacement sensor
    Jiang, Hanjun
    Sun, Xiaojie
    Liu, Fuhao
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2020, 42 (06)
  • [39] Shearing force measurement device with a built-in integrated micro displacement sensor
    Iwasaki, Takuma
    Takeshita, Toshihiro
    Arinaga, Yuji
    Uemura, Koji
    Ando, Hideyuki
    Takeuchi, Satoshi
    Furue, Masutaka
    Higurashi, Eiji
    Sawada, Renshi
    SENSORS AND ACTUATORS A-PHYSICAL, 2015, 221 : 1 - 8
  • [40] Measurement method of tooth friction force for helical gears by laser displacement sensor
    Hanjun Jiang
    Xiaojie Sun
    Fuhao Liu
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2020, 42