IMPROVED CHROMATOGRAPHIC RESOLUTION FOR GAS-CHROMATOGRAPHY MATRIX-ISOLATION INFRARED-SPECTROSCOPY

被引:7
|
作者
KLAWUN, C
SASAKI, TA
WILKINS, CL
CARTER, D
DENT, G
JACKSON, P
CHALMERS, J
机构
[1] UNIV CALIF RIVERSIDE, DEPT CHEM, RIVERSIDE, CA 92521 USA
[2] ICI SPECIALT, MANCHESTER M9 3DA, ENGLAND
[3] ICI WILTON RES CTR, MIDDLESBROUGH TS6 8JE, CLEVELAND, ENGLAND
关键词
GAS CHROMATOGRAPHY MATRIX ISOLATION INFRARED SPECTROSCOPY; GC/MI-IR; CHROMATOGRAPHIC RESOLUTION IMPROVEMENT; HYPHENATED TECHNIQUES; DETECTION LIMITS;
D O I
10.1366/0003702934415228
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
When gas chromatography/matrix isolation infrared spectroscopy (GC/MI-IR) is carried out with a fixed cryodisk rotation speed, chromatographic resolution may be substantially degraded. In this research, an approach allowing dynamic programming of disk rotation speed is shown to result in much improved resolution in reconstructed chromatograms. Use of up to 254 different speeds during a single chromatographic run is possible. Thus, the analyst can match the requirements of any specific separation problem with an appropriate set of cryocollector movement speeds. As a consequence, much improved analytical performance without loss of sensitivity is possible for mixture analysis by GC/MI-IR, as is up to 30% higher apparent chromatographic resolution than is observed with a flame ionization detector. In addition, careful matching of sample spot size and detector area with the appropriate cryodisk speed leads to the detection of as little as 40 picograms of hexachlorobenzene.
引用
收藏
页码:957 / 964
页数:8
相关论文
共 50 条
  • [21] USE OF MATRIX-ISOLATION SPECTROSCOPY IN GAS-CHROMATOGRAPHIC DETECTION
    HEMBREE, DM
    CARTER, WJ
    GARRISON, A
    YOKLEY, R
    MAMANTOV, G
    WEHRY, EL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1981, 181 (MAR): : 128 - ANYL
  • [22] APPLICATION OF GAS-CHROMATOGRAPHY MATRIX-ISOLATION FOURIER-TRANSFORM INFRARED SPECTROMETRY TO DIOXIN DETERMINATIONS
    WURREY, CJ
    BOURNE, S
    KLEOPFER, RD
    ANALYTICAL CHEMISTRY, 1986, 58 (02) : 482 - 483
  • [23] GAS-CHROMATOGRAPHY - MATRIX-ISOLATION - FOURIER TRANSFORM-INFRARED SPECTROMETRY OF NATURAL-PRODUCTS
    COLEMAN, WM
    GORDON, BM
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (09) : 371 - 376
  • [24] IMPROVEMENT IN THE SELECTIVITY OF THE CHEMIGRAM APPROACH IN GAS-CHROMATOGRAPHY INFRARED-SPECTROSCOPY
    PYO, D
    HARADA, K
    ANALYTICAL SCIENCES, 1993, 9 (02) : 279 - 283
  • [25] CELLULOSE ETHER ANALYSIS USING GAS-CHROMATOGRAPHY AND INFRARED-SPECTROSCOPY
    FRIESE, P
    WOCHENBLATT FUR PAPIERFABRIKATION, 1982, 110 (13): : 467 - 467
  • [27] MATRIX-ISOLATION FOURIER-TRANSFORM INFRARED-SPECTROSCOPY IN ANALYTICAL-CHEMISTRY
    MAMANTOV, G
    WEHRY, EL
    HEMBREE, DM
    GARRISON, AA
    HINTON, ER
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1980, 180 (AUG): : 114 - ANYL
  • [28] A STUDY OF THE GAS-PHASE REACTION OF NO2 WITH O-3 BY MATRIX-ISOLATION INFRARED-SPECTROSCOPY
    MORRIS, VR
    BHATIA, SC
    HALL, JH
    JOURNAL OF PHYSICAL CHEMISTRY, 1987, 91 (12): : 3359 - 3361
  • [29] HYDROGENATION OF SOYBEAN OIL - A THIN-LAYER CHROMATOGRAPHY AND GAS-CHROMATOGRAPHY MATRIX-ISOLATION FOURIER-TRANSFORM INFRARED STUDY
    MOSSOBA, MM
    MCDONALD, RE
    ARMSTRONG, DJ
    PAGE, SW
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1991, 39 (04) : 695 - 699
  • [30] INFRARED AND RAMAN MATRIX-ISOLATION SPECTROSCOPY OF SILAETHYLENES
    LAANE, J
    IRWIN, RM
    OHLSEN, JR
    STRUBE, MM
    HARTHCOCK, MA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (APR): : 318 - 318