THERMAL PERFORMANCE OF CYCLIC REGENERATORS OPERATING UNDER VARYING INLET TEMPERATURE CONDITIONS

被引:0
|
作者
FOUMENY, EA [1 ]
HEGGS, PJ [1 ]
机构
[1] UMIST,DEPT CHEM ENGN,MANCHESTER,LANCS,ENGLAND
关键词
D O I
10.1080/08916159508946489
中图分类号
O414.1 [热力学];
学科分类号
摘要
A mathematical simulation of an experimental regenerator has been developed that accounts for heat storage and heat loss from the peripheral pipework and from the regenerator walls as well. The simulation clearly substantiates the experimental results obtained for the regenerator section. In addition to the common dimensionless parameters, the regenerator performance also depends on the inlet fluid temperature variations, the heat capacity of the regenerator wads, the insulation, and the surrounding ambient temperature. The simulation results have revealed an important phenomenon: The average thermal effectiveness of a particular experimental investigation is constant regardless of the magnitude of the ambient temperature. This investigation provides an explanation as to why the experimentally measured values of the thermal effectiveness of the hot and cold strokes differ. Theory predicts that they should be equal at cyclic equilibrium. The simulation clearly shows that the use of internal and external insulations on the regenerator walls greatly reduces the difference in the effectiveness values.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 50 条
  • [41] Influence of inlet pressure and mass flow rate on the temperature rise of superconducting strands in SSTF under the normal operating conditions
    Yoon, CS
    Wang, QL
    Suh, YS
    Choi, SW
    Chung, WH
    Park, H
    Kim, K
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2002, 12 (01) : 1541 - 1544
  • [42] A study of occupant performance under varying indoor thermal conditions during summer in India
    Sharma, Virendra
    Gupta, Raj
    Mathur, Jyotirmay
    Mathur, Sanjay
    ENERGY AND BUILDINGS, 2025, 333
  • [43] MEASURING THERMAL PERFORMANCE OF WALL ASSEMBLIES UNDER DYNAMIC TEMPERATURE CONDITIONS
    VANGEEM, MG
    JOURNAL OF TESTING AND EVALUATION, 1987, 15 (03) : 178 - 187
  • [44] Performance analysis of tilted photovoltaic system integrated with phase change material under varying operating conditions
    Khanna, Sourav
    Reddy, K. S.
    Mallick, Tapas K.
    ENERGY, 2017, 133 : 887 - 899
  • [45] The fracture behaviour of nanostructure added adhesives under ambient temperature and thermal cyclic conditions
    Kanar, Belin
    Akpinar, Salih
    Akpinar, Iclal Avinc
    Akbulut, Hamit
    Ozel, Adnan
    THEORETICAL AND APPLIED FRACTURE MECHANICS, 2018, 97 : 120 - 130
  • [46] On the testing, characterization, and evaluation of PV inverters and dynamic MPPT performance under real varying operating conditions
    Sanchis, Pablo
    Lopez, Jesus
    Ursua, Alfredo
    Gubia, Eugenio
    Marroyo, Luis
    PROGRESS IN PHOTOVOLTAICS, 2007, 15 (06): : 541 - 556
  • [47] AN EXPERIMENTAL INVESTIGATION INTO THE PERFORMANCE OF A DOMESTIC THERMOSYPHON SOLAR WATER HEATER UNDER VARYING OPERATING-CONDITIONS
    ABDALZAHRA, HAA
    JOUDI, KA
    ENERGY CONVERSION AND MANAGEMENT, 1984, 24 (03) : 205 - 214
  • [48] Improvements to the Hydraulic Performance of Culverts under Inlet Control Conditions by Optimisation of Inlet Characteristics
    de Jager, Leon
    van Dijk, Marco
    WATER, 2024, 16 (11)
  • [49] Improved performance of data-driven simulator of liquid rocket engine under varying operating conditions
    Satoh, Daiwa
    Omata, Noriyasu
    Tsutsumi, Seiji
    Hashimoto, Tomoyuki
    Sato, Masaki
    Kimura, Toshiya
    Abe, Masaharu
    ACTA ASTRONAUTICA, 2024, 214 : 473 - 483
  • [50] Performance of a split-spectrum photovoltaic device operating under time-varying spectral conditions
    Torrey, E. R.
    Ruden, P. P.
    Cohen, P. I.
    JOURNAL OF APPLIED PHYSICS, 2011, 109 (07)