Monte Carlo Simulation of Two Ru-106 Eye Plaques in a New Mathematical Human Eye Model

被引:0
|
作者
Mowlavi, Ali Asghar [1 ]
Yazdani, Majed [1 ]
机构
[1] Sabzevar Tarbiat Moallem Univ, Phys Dept, Sabzevar, Iran
来源
IRANIAN JOURNAL OF NUCLEAR MEDICINE | 2008年 / 16卷 / 02期
关键词
Ru-106 eye plaque; Dose calculation; Mathematical human eye model; MCNP4C code;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BEBIG Ruthenium-106 ophthalmic plaques have been used for treatment of uveal melanoma, retinoblastoma, melanoma of the iris and other special applications for many years. The plaques consist of a thin film of Ru-106, a beta emitter, encapsulated in pure silver. The present work proposes a new mathematical eye model for ophthalmic brachytherapy dosimetry. This new model includes detailed description of internal structures, allowing dose determination in different regions of the eye for a more adequate clinical analysis. In the present work, we have used MCNP4C code to calculate relative dose in a new human eye model. The isodose curves and dosimetric characteristics for two Ru-106 eye applicators have been determined. Also, absorbed dose values due to both small CCA and CCB concave applicators were obtained for each one of the different structures which compose the eye model and can give relevant information in eventual clinical analyses.
引用
收藏
页码:16 / 22
页数:7
相关论文
共 50 条
  • [31] A test of the 3D scintillation dosimetry method for a Ru-106 eye plaque applicator
    Kirov, AS
    Piao, JZ
    Mathur, N
    Miller, TR
    Devic, S
    Trichter, S
    Zaider, M
    LoSasso, T
    Soares, C
    MEDICAL PHYSICS, 2005, 32 (06) : 2002 - 2002
  • [32] Accurate estimation of dose distributions inside an eye irradiated with 106Ru plaques
    Brualla, L.
    Sempau, J.
    Zaragoza, F. J.
    Wittig, A.
    Sauerwein, W.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (01) : 68 - 73
  • [33] Preservation of visual acuity after eye-sparing Ru-106 brachytherapy in choroidal melanoma patients
    Pors, Lennart J.
    Marinkovic, Marina
    Deuzeman, Heloisa H.
    Vu, T. H. Khanh
    Kerkhof, Ellen M.
    Rasch, Coen R. N.
    Bleeker, Jaco C.
    Creutzberg, Carien L.
    Beenakker, Jan-Willem M.
    Luyten, Gregorius P. M.
    Horeweg, Nanda
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S297 - S301
  • [34] DOSE CALCULATIONS OF FIVE RU-106 EYE PLAQUE BRACHYTHERAPY WITH MCNP4C CODE
    Jaberi, R.
    Azma, Z.
    Reza, A. Mahmood
    Hosein, Z. Mohammad
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S406 - S406
  • [35] A Matlab toolkit for Ru-106 eye plaque QA, dose calculation, reference table and report generation
    Delombaerde, L.
    Nulens, A.
    De Brabandere, M.
    RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S215 - S217
  • [36] Investigation of EBT3 film and the new PTW Microdiamond detector in verifying Ru-106 eye plaque dose calibrations
    Malone, C.
    Rossiter, D.
    Langan, B.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S741 - S742
  • [37] Monte Carlo Computation of Dose-Volume Histograms in Structures at Risk of an Eye Irradiated with Heterogeneous Ruthenium-106 Plaques
    Zaragoza, Francisco J.
    Eichmann, Marion
    Fluehs, Dirk
    Timmermann, Beate
    Brualla, Lorenzo
    OCULAR ONCOLOGY AND PATHOLOGY, 2020, 6 (05) : 353 - 359
  • [38] Comment on Monte Carlo calculation of the dose distributions of two 106Ru eye applicators [Radiother Oncol 49 (1998) 191-196]
    Brualla, Lorenzo
    Sempau, Josep
    Sauerwein, Wolfgang
    RADIOTHERAPY AND ONCOLOGY, 2012, 104 (02) : 267 - 268
  • [39] Monte Carlo modelling of the spectral reflectance of the human eye
    Preece, SJ
    Claridge, E
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (16): : 2863 - 2877
  • [40] A Monte Carlo Simulation Method for Treatment Planning Optimization of Eye Plaques Using MCNP4C Code
    Shokrani, P.
    Raisali, G.
    Esfahani, A. Janati
    Ghonchenazi, M. Ghasemi
    MEDICAL PHYSICS, 2010, 37 (06) : 3273 - +