Monte Carlo Simulation of Two Ru-106 Eye Plaques in a New Mathematical Human Eye Model

被引:0
|
作者
Mowlavi, Ali Asghar [1 ]
Yazdani, Majed [1 ]
机构
[1] Sabzevar Tarbiat Moallem Univ, Phys Dept, Sabzevar, Iran
来源
IRANIAN JOURNAL OF NUCLEAR MEDICINE | 2008年 / 16卷 / 02期
关键词
Ru-106 eye plaque; Dose calculation; Mathematical human eye model; MCNP4C code;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BEBIG Ruthenium-106 ophthalmic plaques have been used for treatment of uveal melanoma, retinoblastoma, melanoma of the iris and other special applications for many years. The plaques consist of a thin film of Ru-106, a beta emitter, encapsulated in pure silver. The present work proposes a new mathematical eye model for ophthalmic brachytherapy dosimetry. This new model includes detailed description of internal structures, allowing dose determination in different regions of the eye for a more adequate clinical analysis. In the present work, we have used MCNP4C code to calculate relative dose in a new human eye model. The isodose curves and dosimetric characteristics for two Ru-106 eye applicators have been determined. Also, absorbed dose values due to both small CCA and CCB concave applicators were obtained for each one of the different structures which compose the eye model and can give relevant information in eventual clinical analyses.
引用
收藏
页码:16 / 22
页数:7
相关论文
共 50 条
  • [1] Absorbed dose distributions from inhomogeneous Ru-106 eye plaques using Monte Carlo simulation
    Brualla, L.
    Zaragoza, F. J.
    Eichmann, M.
    Fluehs, D.
    Sauerwein, W.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 : 47 - 47
  • [2] Monte Carlo Simulation of the Treatment of Eye Tumors with Ru-106 Plaques: A Study on Maximum Tumor Height and Eccentric Placement
    Brualla, Lorenzo
    Zaragoza, Francisco J.
    Sauerwein, Wolfgang
    OCULAR ONCOLOGY AND PATHOLOGY, 2015, 1 (01) : 2 - 12
  • [3] Dosimetric Investigation of Six Ru-106 Eye Plaques by EBT3 Radiochromic Films and Monte Carlo Simulation
    Arjmand M.
    Ghassemi F.
    Rafiepour P.
    Zeinali R.
    Riazi-Esfahani H.
    Beiki-Ardakani A.
    Journal of Biomedical Physics and Engineering, 2023, 13 (04): : 309 - 316
  • [4] Inhomogeneous Surface Dose Distributions of Ru-106 Eye Plaques
    Eichmann, Marion
    OCULAR ONCOLOGY AND PATHOLOGY, 2018, 4 (01) : 21 - 22
  • [5] Treatment planning for Ru-106 eye plaques: Pitfalls and remedies
    Trichter, S
    Cohen, GN
    LoSasso, T
    McCormick, B
    Abramson, D
    Zaider, M
    RADIOLOGY, 2002, 225 : 192 - 192
  • [6] Monte Carlo estimation of absorbed dose distributions in an anthropomorphic phantom obtained from heterogeneous Ru-106 eye plaques
    Zaragoza, F. J.
    Eichmann, M.
    Fluehs, D.
    Sauerwein, W.
    Brualla, L.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2017, 193 : S11 - S12
  • [7] MONTE CARLO SIMULATION OF RU/RH-106 EYE PLAQUES ON A MIXED QUADRIC AND VOXELISED GEOMETRY
    Brualla, L.
    Fluehs, D.
    Wittig, A.
    Bornfeld, N.
    Sauerwein, W.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S517 - S517
  • [8] Monte Carlo Simulation of the Treatment of Uveal Melanoma Using Measured Heterogeneous Ru-106 Plaques
    Zaragoza, Francisco J.
    Eichmann, Marion
    Fluehs, Dirk
    Wittig, Andrea
    Sauerwein, Wolfgang
    Brualla, Lorenzo
    OCULAR ONCOLOGY AND PATHOLOGY, 2018, 5 (04) : 276 - 283
  • [9] Ru-106 eye plaques for treatment of ocular melanoma - Practical issues
    Mourtada, F.
    Horton, J.
    Gombos, D.
    Garden, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S696 - S696
  • [10] Monte Carlo investigation of dose distribution of two model 106 Ru/ 106 Rh ophthalmic plaques in a realistic human eye model with different uveal melanoma size
    Fardi, Zeinab
    Taherparvar, Payvand
    APPLIED RADIATION AND ISOTOPES, 2025, 217