PARTICLE CONCENTRATION, SIZE AND TURBIDITY

被引:39
|
作者
KLEIZEN, HH
DEPUTTER, AB
VANDERBEEK, M
HUYNINK, SJ
机构
[1] Department of Chemical Engineering, Delft University of Technology, PO Box 5045
来源
FILTRATION & SEPARATION | 1995年 / 32卷 / 09期
关键词
D O I
10.1016/S0015-1882(97)84175-4
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The amount of light scattered by particles in a suspension depends on the concentration and geometry of the particles, and on the optical properties of the suspension. in the paper a new method is presented to extract particle concentration and a characteristic particle sire from turbidimeter readings. The method requires a turbidimeter capable of measuring the forward (12 degrees) and sideways (90 degrees) scattered light simultaneously. The turbidimeter must be calibrated with several samples with known particle concentration and characteristic size. Results are presented for the calibration of filter aids, an industrial pigment and yeast. An example is given of its intended use: the on-line analysis of filtrate turbidity. The method is of course limited to the range of particle concentration (1-200 ppm) and characteristic particle size (1-100 mu m) used in the calibration. A second limitation arises from the fact that other parameters influencing scattering (optical properties, particle shape and porosity, width of the size distribution) are not considered. The anomalous behaviour of baker's yeast can be explained in this way.
引用
收藏
页码:897 / 901
页数:5
相关论文
共 50 条
  • [41] Effects of particle concentration and size on tooth wear
    Rodriguez-Rojas, Fernando
    Borrero-Lopez, Oscar
    Constantino, Paul J.
    Guiberteau, Fernando
    Lawn, Brian R.
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2019, 168 : 206 - 206
  • [42] MEASUREMENT OF PARTICLE SIZE AND CONCENTRATION OF HOMOGENEOUS AEROSOLS
    INN, ECY
    JOURNAL OF COLLOID SCIENCE, 1951, 6 (04): : 368 - 371
  • [43] SAMPLE CONCENTRATION IN PARTICLE-SIZE ANALYSIS
    BERG, RH
    AMERICAN LABORATORY, 1992, 24 (03) : 83 - 84
  • [44] Effect of particle size on critical coagulation concentration
    Hsu, JP
    Liu, BT
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1998, 198 (01) : 186 - 189
  • [45] ACOUSTICAL MEASUREMENTS OF AEROSOL PARTICLE SIZE AND CONCENTRATION
    DOBBINS, RA
    TEMKIN, S
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1967, 25 (03) : 329 - &
  • [46] Errors in particle size and concentration analysis of pharmaceuticals
    Merkus, Henk G.
    PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2020, 25 (02) : 252 - 259
  • [47] Slurry ultrasonic particle size and concentration characterization
    Bamberger, JA
    Kytomaa, HK
    Greenwood, MS
    SCIENCE AND TECHNOLOGY FOR DISPOSAL OF RADIOACTIVE TANK WASTES, 1998, : 485 - 495
  • [48] Particle-scale analysis on dynamic response of turbidity currents to sediment concentration and bedforms
    Lu, Yang
    Liu, Xiaolei
    Xie, Xiaotian
    Sun, Junkai
    Yang, Yuping
    Guo, Xingsen
    PHYSICS OF FLUIDS, 2024, 36 (03)
  • [49] THE EFFECT OF PARTICLE SIZE AND AMBIENT OXIDIZER CONCENTRATION ON METAL PARTICLE IGNITION
    Meinkoehn, Dirk
    COMBUSTION SCIENCE AND TECHNOLOGY, 2009, 181 (08) : 1007 - 1037
  • [50] PARTICLE-SIZE DISTRIBUTIONS FROM SPECTRAL TURBIDITY - A SINGULAR-SYSTEM ANALYSIS
    BERTERO, M
    DEMOL, C
    PIKE, ER
    INVERSE PROBLEMS, 1986, 2 (03) : 247 - 258