THE USE AND HANDLING OF ACRYLIC BONE-CEMENT IN DANISH ORTHOPEDIC DEPARTMENTS

被引:5
|
作者
DARRE, E
HOLMICH, P
JENSEN, JS
机构
[1] Department of Orthopaedics, University of Copenhagen, Rigshospitalet, Copenhagen Ø, DK-2100
来源
PHARMACOLOGY & TOXICOLOGY | 1993年 / 72卷 / 4-5期
关键词
D O I
10.1111/j.1600-0773.1993.tb01659.x
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
In order to evaluate the use and handling of acrylic bone cement, questionnaires were presented to all Danish orthopaedic departments in 1987 and again in 1992. Marked improvements in the environmental safety precautions for handling of bone cement had taken place during the 5-year period. In 1992, the intraoperative handling and use of bone cement is thus generally considered safe. Further improvements are still to be advocated in some departments. The exposure to methylmethacrylate monomer (MMA) vapour during the cementation procedures should be eliminated by local punctual field suction or change to a bone cement with a lower content of monomer (MMA/n-decylmethacrylate/isobornylmethacrylate bone cement). Unnecessary manual contact with the cement should be avoided, and if contact is necessary, special protective gloves (butyl rubber gloves or 4H-gloves(R)) should be used in addition to ordinary surgical gloves.
引用
收藏
页码:332 / 335
页数:4
相关论文
共 50 条
  • [41] Advances in orthopedic bone cement: Two-solution acrylic bone cement.
    Gilbert, JL
    Hasenwinkel, JM
    Mroczkowski, M
    Shim, JB
    Merkhan, I
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 224 : U508 - U508
  • [42] THE DEPOT ADMINISTRATION OF PENICILLIN-G AND GENTAMICIN IN ACRYLIC BONE-CEMENT
    HOFF, SF
    FITZGERALD, RH
    KELLY, PJ
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (05): : 798 - 804
  • [43] THE RELEASE IN-VITRO OF VANCOMYCIN AND TOBRAMYCIN FROM ACRYLIC BONE-CEMENT
    SEYRAL, P
    ZANNIER, A
    ARGENSON, JN
    RAOULT, D
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1994, 33 (02) : 337 - 339
  • [44] A REDUCED-MODULUS ACRYLIC BONE-CEMENT - PRELIMINARY-RESULTS
    LITSKY, AS
    ROSE, RM
    RUBIN, CT
    THRASHER, EL
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (04) : 623 - 626
  • [45] USE OF ANTIBIOTIC-CONTAINING BONE-CEMENT
    MURRAY, WR
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1984, (190) : 89 - 95
  • [46] RELEASE OF GENTAMICIN FROM ACRYLIC BONE-CEMENT - ELUTION AND DIFFUSION STUDIES
    BAKER, AS
    GREENHAM, LW
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (10): : 1551 - 1557
  • [47] FATIGUE OF ACRYLIC BONE-CEMENT - THE INFLUENCE OF STRAIN RANGE AND MEAN STRAIN
    GATES, EI
    CARTER, DR
    HARRIS, WH
    JOURNAL OF BIOMECHANICS, 1983, 16 (04) : 284 - 284
  • [48] THE RELEASE OF ANTI-NEOPLASTIC DRUGS FROM ACRYLIC BONE-CEMENT
    DEKEL, S
    WASSERLAUF, S
    SALAMA, R
    WARSHAWSKY, A
    MAZOR, Y
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (05): : 845 - 846
  • [49] RADIOACTIVITY OF BONE-CEMENT
    SCHERER, MA
    WINKLER, R
    ASCHERL, R
    LENZ, E
    RADIOLOGE, 1993, 33 (01): : 46 - 50
  • [50] MECHANICAL-PROPERTIES OF VACUUM-MIXED ACRYLIC BONE-CEMENT
    LEWIS, G
    AUSTIN, GE
    JOURNAL OF APPLIED BIOMATERIALS, 1994, 5 (04) : 307 - 314