THE POTENTIOMETRIC UREA BIOSENSOR USING CHITOSAN MEMBRANE

被引:0
|
作者
Mulyasuryani, Ani [1 ]
Roosdiana, Anna [1 ]
Srihardyastutie, Arie [1 ]
机构
[1] Brawijaya Univ Jalan Veteran, Chem Dept, Malang, Indonesia
关键词
biosensor; potentiometry; urea; chitosan membrane;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Potentiometric urea biosensor development is based on urea hydrolysis by urease resulted CO2. The biosensor is used chitosan membrane and the H3O+ electrode as a transducer. The research was studied of effecting pH and membrane thickness to the biosensor performance. The best biosensor performance resulted at pH 7.3 and membrane thickness of 0.2 mm. The biosensor has a Nerntian factor of 28.47 mV/decade; the concentration range is 0.1 up to 6.00 ppm; and the limit of detection is 0.073 ppm. The response time of this biosensor is 280 seconds, efficiency 32 samples and accuracy 94% up to 99%.
引用
收藏
页码:162 / 166
页数:5
相关论文
共 50 条
  • [31] POLYPYRROLE-BASED POTENTIOMETRIC BIOSENSOR FOR UREA .2. ANALYTICAL OPTIMIZATION
    ADELOJU, SB
    SHAW, SJ
    WALLACE, GG
    ANALYTICA CHIMICA ACTA, 1993, 281 (03) : 621 - 627
  • [32] Polyelectrolyte microcapsules with urease and paramagnetic particles as a basis for a potentiometric biosensor for determining urea
    Reshetilov, A. N.
    Plekhanova, Yu. V.
    Tikhonenko, S. A.
    Dubrovskii, A. V.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (11) : 1368 - 1372
  • [33] Urea potentiometric biosensor based on modified electrodes with urease immobilized on polyethylenimine films
    Lakard, B
    Herlem, G
    Lakard, S
    Antoniou, A
    Fahys, B
    BIOSENSORS & BIOELECTRONICS, 2004, 19 (12): : 1641 - 1647
  • [34] Preparation, characterization and application of urease nanoparticles for construction of an improved potentiometric urea biosensor
    Jakhar, Seema
    Pundir, C. S.
    BIOSENSORS & BIOELECTRONICS, 2018, 100 : 242 - 250
  • [35] Development of a Potentiometric Glucose Biosensor Based on a PVC Membrane Electrode
    Kang Pingli
    Ma Xiaoyan
    Lin Mi
    Liu Xinfei
    Wang Jianguo
    ACTA CHIMICA SINICA, 2011, 69 (24) : 3002 - 3006
  • [36] Potentiometric cholinesterase biosensor with a membrane modified with calix[4]resorcinolarene
    Evtyugin, GA
    Muslinkina, LA
    Budnikov, GK
    Kazakova, EK
    JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 54 (04) : 367 - 371
  • [37] Application of potentiometric biosensor based on recombinant urease for urea determination in blood serum and hemodialyzate
    Marchenko, S. V.
    Kucherenko, I. S.
    Hereshko, A. N.
    Panasiuk, I. V.
    Soldatkin, O. O.
    El'skaya, A. V.
    Soldatkin, A. P.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 : 981 - 986
  • [38] Potentiometric Urea Biosensor Based on Ion-Selective Electrode by Different Immobilization Procedures
    NienHsuan Chou
    JungChuan Chou
    ShenKan Hsiung
    稀有金属材料与工程, 2006, (S3) : 309 - 312
  • [39] Potentiometric Urea Biosensor Based on an Immobilised Fullerene-Urease Bio-Conjugate
    Saeedfar, Kasra
    Heng, Lee Yook
    Ling, Tan Ling
    Rezayi, Majid
    SENSORS, 2013, 13 (12) : 16851 - 16866
  • [40] Potentiometric urea biosensor based on ion-selective electrode by different immobilization procedures
    Chou, Nien-Hsuan
    Chou, Jung-Chuan
    Sun, Tai-Ping
    Hsiung, Shen-Kan
    RARE METAL MATERIALS AND ENGINEERING, 2006, 35 : 309 - 312