Active and Reactive Power Control for Doubly-Fed Wound Rotor Induction Generator

被引:171
|
作者
Yamamoto, Mitsutoshi [1 ]
Motoyoshi, Osamu [1 ]
机构
[1] Fuji Elect Corp Res & Dev Ltd, 1 Fuji Machi, Hino, Tokyo 191, Japan
关键词
D O I
10.1109/63.97761
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new power control system for a doubly-fed wound rotor induction generator has been developed. This power control system has applied a control method using a rotating reference frame fixed on the gap flux of the generator and can control active and reactive power independently and stably. The characteristics of the control system have been proved by experiment. Moreover, harmonic currents fed to the rotor windings are transmitted to the stator winding changing its frequency. The transmitting characteristics of harmonic currents have been analyzed and verified by experiments.
引用
收藏
页码:624 / 629
页数:6
相关论文
共 50 条
  • [41] Decoupled power control of wind turbine based on doubly-fed induction generator
    Li, D. D.
    2006 1st IEEE Conference on Industrial Electronics and Applications, Vols 1-3, 2006, : 915 - 919
  • [42] Real-Time Simulation for Active and Reactive Power Control of Doubly Fed Induction Generator
    Maharjan, Rabindra
    Kamalasadan, Sukumar
    2013 NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2013,
  • [43] Robust Adaptive Reactive Power Control for Doubly Fed Induction Generator
    Wen, Huabin
    Zeng, Yu
    Wang, Lei
    Yang, Feng
    Song, Y. D.
    ABSTRACT AND APPLIED ANALYSIS, 2014,
  • [44] Accurate Rotor Fault Detection in Doubly-Fed Wound-Rotor Induction Machine
    Gritli, Y.
    Tani, A.
    Rossi, C.
    Casadei, D.
    Filippetti, F.
    2017 6TH INTERNATIONAL CONFERENCE ON CLEAN ELECTRICAL POWER (ICCEP): RENEWABLE ENERGY IMPACT, 2017, : 756 - 760
  • [45] MATHEMATICAL MODEL FOR THE DOUBLY-FED WOUND ROTOR GENERATOR - PART II.
    Brady, Frank J.
    1600,
  • [46] Generalized Vector Control with Reactive Power Control for Brushless Doubly-Fed Induction Machines
    Duan, Qiwei
    Liu, Shi
    Schlaberg, H. Inaki
    Long, Teng
    JOURNAL OF POWER ELECTRONICS, 2018, 18 (03) : 817 - 825
  • [47] Torque and Reactive Power Control of Doubly-Fed Induction Machine with Matrix Converter
    Shapoval, Ivan
    Peresada, Sergei
    Asher, Greg
    Clare, Jon
    2008 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-5, 2008, : 2529 - +
  • [48] Impact of reactive power control on transient stability for doubly-fed induction machines
    Wangsathitwong, S.
    Sirisurnrannukul, S.
    Chatratana, S.
    Deleroi, W.
    2007 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, 2007, : 257 - +
  • [49] The influence of doubly-fed induction generator on stability of power system
    Hao, Zheng-Hang
    Yu, Yi-Xin
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2011, 39 (03): : 7 - 11
  • [50] The Control Strategy of The Rotor-Side PWM Converter Based on Doubly-Fed Induction Generator
    Zhao, Meihua
    Fan, Min
    Wu, Xiaoxin
    AUTOMATIC MANUFACTURING SYSTEMS II, PTS 1 AND 2, 2012, 542-543 : 204 - +