AIRBORNE ASBESTOS LEVELS IN BUILDINGS - MAINTENANCE WORKER AND OCCUPANT EXPOSURES

被引:0
|
作者
PRICE, B
CRUMP, KS
BAIRD, EC
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A substantial number of air samples have been collected during the past few years to measure airborne asbestos levels in buildings with asbestos-containing materials (ACM). These samples fall into two categories: (i) samples collected to measure the exposure of workers while they were engaged in routine maintenance and repair activities; and (ii) samples collected during normal building activity to measure prevalent levels in buildings. The measurements derived from these samples have been compiled and summarized to provide estimates of the airborne asbestos exposure of workers engaged in routine maintenance and repair work and by other building occupants. These data indicate that maintenance and repair workers in buildings with ACM, after accounting for the frequency and duration of these types of activities, have annual exposure levels ranging from a median value of 0.002 fibers per cubic centimeter (f/cc) per year to 0.02 f/cc per year at the 90th percentile. Building occupants not involved in maintenance and repair work experience average exposure levels ranging from 0.00003 f/cc to 0.0005 f/cc.
引用
收藏
页码:357 / 374
页数:18
相关论文
共 50 条
  • [21] WORKER EXPOSURES DURING MAINTENANCE OF ION IMPLANTERS IN THE SEMICONDUCTOR INDUSTRY
    MCCARTHY, CM
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1985, 132 (08) : C357 - C357
  • [22] Evaluation of bricklayer exposures to airborne asbestos in steel mills (1972-1981)
    Murbach, D.
    Chapman, P.
    Madl, A.
    Brown, J.
    Paustenbach, D.
    EPIDEMIOLOGY, 2006, 17 (06) : S462 - S463
  • [23] Airborne asbestos exposures associated with the installation and removal of roofing products (Withdrawn Publication)
    Lotter, Jason T.
    Roberts, Ben
    Henshaw, John L.
    Pierce, Jennifer S.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2016, 13 (08) : D121 - D131
  • [24] Personal Exposures to Asbestos Fibers During Brake Maintenance of Passenger Vehicles
    Cely-Garcia, Maria Fernanda
    Sanchez, Mauricio
    Breysse, Patrick N.
    Ramos-Bonilla, Juan P.
    ANNALS OF OCCUPATIONAL HYGIENE, 2012, 56 (09): : 985 - 999
  • [25] Automobile brake maintenance and airborne chrysotile fiber exposures.
    Banasik, M
    Van Orden, DR
    Blake, C
    Harbison, RD
    TOXICOLOGICAL SCIENCES, 2003, 72 : 183 - 184
  • [26] STUDY OF AIRBORNE RADON LEVELS INSIDE BUILDINGS
    KHAN, AJ
    TYAGI, RK
    PRASAD, R
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1989, 16 (01): : 23 - 27
  • [27] Study of airborne radon levels inside buildings
    Khan, A.J.
    Tyagi, R.K.
    Prasad, Rajendra
    Nuclear tracks, 1989, 16 (01): : 23 - 27
  • [28] Evaluation of background exposures to airborne asbestos on maritime shipping vessels (1972-1992)
    Murbach, D.
    Chapman, P.
    Madl, A.
    Paustenbach, D.
    EPIDEMIOLOGY, 2006, 17 (06) : S462 - S462
  • [29] Relationship between Quality of Building Maintenance System and Occupant Satisfaction for Office Buildings
    Hamid, A. H. A.
    Othman, M. H.
    BUILDING SURVEYING AND TECHNOLOGY UNDERGRADUATE CONFERENCE, 2014, 10
  • [30] Characterization of Airborne Particulates and Worker Exposures in Electro-static Powder Coating Operations
    Lee, Chia-wei
    Chung, Shun-hui
    Hsu, Yu-ting
    Chang, Hong-bin
    Chien, Yeh-chung
    ANNALS OF WORK EXPOSURES AND HEALTH, 2021, 65 (09) : 1075 - 1084